Skip to main content
Glama
fdm-mcp

fdm-mcp

by akshara-ns

Check a printed cantilever

check_cantilever
Read-onlyIdempotent

Calculates bending stress, safety factor, breaking load, and tip deflection for an end-loaded 3D-printed bracket, hook, or clip so you can assess strength and orientation before printing or use.

Instructions

Bending stress, safety factor, breaking load and tip deflection of a printed bracket, hook or clip loaded at its end (HW4 tool). Errors: no load given, values outside their ranges.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "length_mm": "<length_mm>",
      "width_mm": "<width_mm>",
      "thickness_mm": "<thickness_mm>"
    },
    "name": "check_cantilever"
  }
}

Input Schema

NameRequiredDescriptionDefault
load_NNoEnd load as a force (give this or load_kg) [N, 0.01–5000]
load_kgNoEnd load as a hung mass (give this or load_N) [kg, 0.001–500]
materialNoFilament (values from manufacturer data sheets).PLA
width_mmYesArm width [mm, 1–200]
length_mmYesArm length from root to load [mm, 5–400]
orientationNoflat: layers run along the arm (strong); upright: load pulls layers apart (weak)flat
thickness_mmYesDepth in the bending direction [mm, 0.8–100]
interlayer_factorNoStrength across layers / in-plane strength; default 0.5 [-, 0.1–1]
target_safety_factorNoRequired safety factor; default 2 [-, 1–10]

Output Schema

NameRequiredDescriptionDefault
toolYes
checksYes
inputsYesEvery input actually used, after defaults.
resultsYes
summaryYes
verdictYesWorst status among the checks.
decisionNoRecommended action (new tools only).
featuresNoPer-feature table (check_deviated_part).
warningsYes
assumptionsYes
human_checksNoWhat a person must verify before acting.
defaults_usedYesInputs the user did not give and the default applied.

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv0.1.0

TDQS

A3.8/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare readOnly, idempotent, non-destructive and closed-world, so the safety profile is covered elsewhere. The description adds value beyond that by enumerating the four computed results and by disclosing failure modes ('no load given, values outside their ranges'), which tells the agent how the call can fail. It stops short of describing units or default behavior, but the error disclosure is real added context.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

A single front-loaded sentence listing outputs before geometry, followed by a compact error note — nothing redundant. The parenthetical '(HW4 tool)' is internal jargon that adds no selection value, a minor blemish.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness5/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

With an output schema present, the description need not explain return values, and with 100% schema coverage the nine parameters are fully documented in structured fields. The description supplies the remaining essentials: what is computed, the loading configuration, and the error conditions.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100%, including ranges, units, enum meanings for orientation and the load_N/load_kg alternative, so the schema carries parameter semantics. The description adds only the framing that the load acts at the tip; baseline 3 applies when the schema does the heavy lifting.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names the exact outputs (bending stress, safety factor, breaking load, tip deflection) and the exact geometry (a printed bracket, hook or clip loaded at its end), so an agent can tell it apart from check_container or check_deviated_part. It is a noun phrase rather than a verb+resource, but the resource and computed quantities are unambiguous.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

'loaded at its end' is an implicit applicability condition that scopes the tool to end-loaded cantilever geometry, which is useful. However, it never names a sibling to route to (e.g. check_deviated_part for non-cantilever parts) nor states when not to use it, leaving the agent to infer the boundary from sibling names alone.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.