kc_modbus_mcp
Click on "Install Server".
Wait a few minutes for the server to deploy. Once ready, it will show a "Started" state.
In the chat, type
@followed by the MCP server name and your instructions, e.g., "@kc_modbus_mcpRead the factory temperature from the simulator"
That's it! The server will respond to your query, and you can continue using it as needed.
Here is a step-by-step guide with screenshots.
"Read the factory temperature" -- Modbus MCP
Look, nobody wants to memorize that register 40001 is the temperature sensor. Life is too short and Modbus addresses are too many. This is an MCP Server for Modbus TCP devices -- you define device profiles in YAML, and then AI agents can read/write PLC registers by name like civilized beings.
It also ships with a built-in simulator, because we all know you don't have a PLC sitting on your desk. (And if you do, please dust it off.)
Why This Exists
I kept looking at existing MCP servers for Modbus and kept finding the same four disappointments:
No semantic register mapping -- the AI has to know raw addresses like
40001. Asking it to "read temperature" gets you a blank stare.No data type conversion -- everything comes back as raw uint16, because apparently float32 is too fancy.
No built-in simulator -- want to test? Go buy hardware. Or beg a colleague. Or stare at the ceiling.
No device profiles -- no way to pre-configure connection details and register maps, so you get to type the same host/port/slave_id over and over like it's 1998.
So I did the unreasonable thing and fixed all four myself.
Architecture
User (CLI / Chat / OpenClaw)
→ AI Agent (Claude / OpenClaw / etc.)
→ MCP Protocol (Streamable HTTP)
→ kc_modbus_mcp (FastMCP Server)
→ Profile Manager (YAML device profiles)
→ pymodbus (async Modbus TCP client)
→ Modbus TCP Device / Built-in SimulatorFeatures
Natural language control -- "read the factory temperature" just works. No address lookup tables taped to your monitor.
YAML device profiles -- map register names to addresses, data types, units, and scaling. Finally, configuration that reads like English.
8 MCP tools -- 5 profile-based + 3 raw mode for when you need to go full hacker.
Auto data type conversion -- float32, int32, uint16, bool -- with byte order and scale support, because doing bit math in your head at 2 AM is not a personality trait.
Built-in Modbus TCP simulator -- sine-wave temperature, random humidity/pressure, writable coils. Your imaginary factory is doing great.
Docker-ready --
docker compose up -dand you're in business. Two containers, zero excuses.OpenClaw skill -- wrapper script for local LLM agents who prefer the command line lifestyle.
Demo
Security Notice: This is a POC/development project designed for trusted LAN environments. The MCP server does not implement authentication. Raw mode allows read/write access to any reachable Modbus device. Do not expose service ports to the public internet without additional security measures.
Quick Start
Three terminals, five minutes, zero soldering required.
1. Clone and install
git clone https://github.com/KerberosClaw/kc_modbus_mcp.git
cd kc_modbus_mcp
uv sync2. Start the simulator
uv run python simulator.py
# Modbus TCP simulator running on port 50203. Start the MCP server
# In another terminal
uv run python server.py
# MCP server running on port 8765, loaded devices.yaml4. Test with MCP client
npm install -g mcporter
mcporter config add modbus --url http://localhost:8765/mcp
mcporter call modbus.list_devices
mcporter call modbus.read_device device=factory_sensor register=temperature
mcporter call modbus.write_device device=factory_sensor register=motor_speed value=1500
mcporter call modbus.device_status device=factory_sensorOr use Docker Compose
For the "I don't want to open three terminals" crowd (understandable):
docker compose up -d
# Simulator on :5020, MCP server on :8765Device Profile (YAML)
This is where the magic happens. Well, "magic" is generous -- it's just YAML. But it beats memorizing hex addresses. Define your Modbus devices in devices.yaml:
devices:
factory_sensor:
host: 192.168.1.100
port: 502
slave_id: 1
byte_order: big # big | little | mixed
registers:
temperature:
address: 0
function_code: 3 # 3=holding, 4=input
data_type: float32 # uint16, int16, uint32, int32, float32, bool
scale: 0.1
unit: "°C"
access: read
description: "Ambient temperature sensor"
motor_speed:
address: 4
function_code: 3
data_type: uint16
unit: "RPM"
access: read_write
description: "Motor speed setpoint"
pump_on:
address: 0
function_code: 1 # 1=coil
data_type: bool
access: read_write
description: "Pump on/off switch"Supported Data Types
Type | Registers | Range |
| coil (1 bit) | true/false |
| 1 | 0 – 65535 |
| 1 | -32768 – 32767 |
| 2 | 0 – 4294967295 |
| 2 | -2147483648 – 2147483647 |
| 2 | IEEE 754 |
Supported Function Codes
Code | Name | Access |
1 | Read Coils | read |
2 | Read Discrete Inputs | read |
3 | Read Holding Registers | read/write |
4 | Read Input Registers | read |
MCP Tools
Profile Mode (primary)
The user-friendly stuff. The reason this project exists.
Tool | Description |
| List all configured devices |
| List all registers of a device with metadata |
| Read a named register -- returns converted value + unit |
| Write a value to a named register |
| Check if a device is online |
Raw Mode (advanced)
For when you need to bypass all that nice abstraction and talk to registers like it's a bare metal Tuesday.
Tool | Description |
| Raw read by host/port/slave_id/fc/address |
| Raw write by host/port/slave_id/fc/address |
| Scan address range for non-zero values |
Built-in Simulator
A pymodbus-based Modbus TCP server that pretends to be a factory. The data is fake but the protocol is real. No hardware needed -- your laptop is the factory now.
Register | Address | FC | Type | Behavior |
temperature | HR 0-1 | 3 | float32 | Sine wave 20~30°C |
humidity | HR 2-3 | 3 | float32 | Random 40~60%RH |
motor_speed | HR 4 | 3 | uint16 | Holds written value |
pressure | IR 0 | 4 | uint16 | Random 900~1100 kPa |
pump_on | Coil 0 | 1 | bool | Holds written value |
valve_open | Coil 1 | 1 | bool | Holds written value |
Project Structure
kc_modbus_mcp/
├── server.py # MCP Server entry point
├── simulator.py # Built-in Modbus TCP simulator
├── devices.yaml # Example device profile
├── src/
│ ├── profile.py # YAML profile loader + register resolver
│ ├── client.py # pymodbus async client wrapper
│ ├── converter.py # Data type conversion (raw ↔ engineering value)
│ └── tools.py # MCP tool definitions
├── openclaw-skill/ # OpenClaw skill wrapper
├── tests/ # Automated tests
├── docker-compose.yml
├── Dockerfile
├── pyproject.toml
├── DESIGN.md # Design document (Chinese)
├── .env.example
└── LICENSEEnvironment Variables
Sensible defaults included, because nobody should have to configure things just to see if they work.
Variable | Default | Description |
|
| Path to device profile YAML |
|
| MCP server bind address |
|
| MCP server port |
|
| Simulator bind address |
|
| Simulator port |
OpenClaw Integration
For OpenClaw / local LLM agents, a wrapper script turns verbose MCP calls into something you can actually type without getting carpal tunnel:
modbus list
modbus status factory_sensor
modbus read factory_sensor temperature
modbus write factory_sensor motor_speed 1500See openclaw-skill/SKILL.md for details.
TODO
Things I will definitely get to. Eventually. Probably.
Multi-device connection pooling
Polling mode with configurable cache interval
Change detection (notify on value changes)
Modbus RTU (Serial) support
Web UI for device profile editing
This server cannot be installed
Resources
Unclaimed servers have limited discoverability.
Looking for Admin?
If you are the server author, to access and configure the admin panel.
Latest Blog Posts
MCP directory API
We provide all the information about MCP servers via our MCP API.
curl -X GET 'https://glama.ai/api/mcp/v1/servers/KerberosClaw/kc_modbus_mcp'
If you have feedback or need assistance with the MCP directory API, please join our Discord server