Skip to main content
Glama

MCP for Crestron 客户端

用自然语言从 Claude 控制 Crestron 4-Series AV 系统。这是 MCP for Crestron 的客户端部分:一个 MCP 服务器,将 Claude(Desktop 或 Code)连接到运行 MCP for Crestron 模块的处理器,通过 stdio 将系统暴露为 MCP 工具。它通过 TCP 使用 MCP for Crestron 文本协议(参见 PROTOCOL.md),并带有安全密钥 + TLS 认证。

MCP for Crestron:用通俗英语从 Claude 控制会议室

用通俗英语与你的 Crestron 系统对话。观看完整演示(1:19)»

客户端是免费的。控制处理器需要该处理器已获得许可(或处于免费试用期)。参见许可。一个处理器许可证为 AUD $249(含 GST);每个处理器还可获得三次免费的 1 周试用。在 https://solutionav.com.au/crestron-mcp/ 获取许可证。

安装

Claude Desktop(推荐)

从 https://solutionav.com.au/crestron-mcp/ 下载 mcp-for-crestron.mcpb 并打开它(或设置 → 扩展 → 安装)。输入处理器的地址及其安全密钥(显示在 MCP Server Config 模块的 Key 输出上);端口默认为 50794。

Claude Code / 其他 MCP 主机

无需下载。直接从 npm 运行:

claude mcp add crestron \
  --env CRESTRON_HOST=10.0.1.38 \
  --env CRESTRON_KEY=<the processor's secure key> \
  -- npx -y mcp-for-crestron

Related MCP server: claude-c2

配置

按从低到高的优先级解析:入口旁边的 config.json、环境变量,然后是 CLI 参数(<host> [port])。

环境变量

含义

CRESTRON_HOST

处理器 IP / 主机名(必填)

CRESTRON_PORT

TCP 端口(默认 50794)

CRESTRON_KEY

安全密钥(模式 2);启用 TLS + 认证

CRESTRON_AUTH

密码(仅模式 1)

CRESTRON_TLS

无密钥时强制使用 TLS

工具

discover_crestron_system、list_crestron_rooms、list_crestron_devices、query_crestron_device、get_crestron_time、control_crestron_device、set_crestron_devices、pulse_crestron_device、ramp_crestron_device、cancel_crestron_device、get_room_status、activate_crestron_license、get_crestron_license_status、start_crestron_trial。

参见 AGENT_GUIDE.md 了解助手应如何使用它们(时序、场景、渐变、轻推而非纠缠的许可礼仪)。

许可

处理器必须先获得许可,才能接受控制或查询命令。如果未获得许可,每个工具都会返回包含处理器**激活码(其 MAC)**的指引。有两种前进方式,都通过聊天进行:

  • 免费试用:start_crestron_trial(无需付款;每个处理器最多 3 × 1 周)。

  • 购买:在 https://solutionav.com.au/crestron-mcp/ 为该 MAC 获取密钥,将其粘贴到聊天中,助手会调用 activate_crestron_license。

许可证存储在处理器上(绑定到其 MAC),因此重启后仍然有效,并覆盖所有客户端。购买的密钥仅适用于那一台处理器,因此在聊天中接收是安全的。

开发

npm install
npm run build      # tsc -> dist/
npm start          # node dist/index.js
npm run mcpb       # build the Claude Desktop .mcpb (needs bun)

许可证

MIT。参见 LICENSE。(客户端是开放的;产品是设备上的每处理器许可证。)

商标

Crestron 是 Crestron Electronics, Inc. 的注册商标;MCP for Crestron 是 Solution AV Automation 的产品,与 Crestron 无关联,也未获得 Crestron 的认可。

Available Tools

14 tools
activate_crestron_licenseA

Activate (license) the Crestron processor with a license key the user provides. Use this when a command fails because the processor isn't licensed: the error explains how, and shows the processor's activation code (MAC). Ask the user for the license key issued for that code, then call this with it. Activation is one-time - the key is stored on the processor, so it stays licensed for every client and across reboots. The key is not a secret (it only works on this one processor), so it's fine to receive it in chat.

Inputs: license_key (required).

cancel_crestron_deviceA

Stop/cancel activity on a device: stop a ramp (fade) in progress and leave the level where it is, release a pulse in progress to off, and clear any pending delayed action (a scheduled set or pulse). Does not otherwise change the device's value - a device that is simply on/high from a normal set stays on. Use for "stop the fade", "stop ringing the bell", "cancel that timer". Works on any device type.

Inputs: device_id (required).

control_crestron_deviceA

Set a device's value. Optionally schedule it to run after a delay (delay_ms), e.g. "turn the porch light on in 30 seconds".

Inputs: device_id (required), value (required), delay_ms.

discover_crestron_systemA

Discover the devices and capabilities available in the Crestron system. Returns rooms, categories, and device counts.

Inputs: no named parameters.

get_crestron_license_statusA

Check the processor's license/trial state: whether it's licensed right now, whether that's a time-limited free trial (time_limited), how much trial time remains (remaining_human / remaining_ms), the processor MAC, and a buy_url. Call it to orient at the start of a session and whenever license status is relevant. If it's a trial, mention the remaining time naturally; as it gets low (under ~2 days) gently offer to start another free trial or buy a license. Nudge, don't nag.

Inputs: no named parameters.

get_crestron_timeA

Get the processor's current time as epoch milliseconds (epoch_ms) and ISO 8601 (iso). Use it to correlate the absolute *_at timestamps from query_crestron_device, or whenever you need the system's real time (no need to decode a wired clock).

Inputs: no named parameters.

get_room_statusC

Get the status of every device in a room.

Inputs: room_name (required).

list_crestron_devicesA

List controllable devices, optionally filtered by room and/or category (Lighting, AV, HVAC, Shades).

Inputs: room, category.

list_crestron_roomsA

List all rooms in the building with their device counts.

Inputs: no named parameters.

pulse_crestron_deviceA

Momentarily pulse a DIGITAL device: drive it on for pulse_ms, then back off - a simulated button press. Use for momentary triggers like "press the doorbell", "tap the projector power button", "trigger the gate". Optionally wait delay_ms before the pulse. Digital devices only; analog and serial devices are rejected (use control_crestron_device / ramp_crestron_device).

Inputs: device_id (required), pulse_ms (required), delay_ms.

query_crestron_deviceA

Get the live state of a device: its current value plus whether it is idle, ramping (with target and completes_at), or pulsing (releases_at), and any pending scheduled action (with fires_at). Time fields are epoch milliseconds (matching get_crestron_time); remaining_ms / in_ms tell you directly how long until it finishes/fires, so you can decide how long to wait without polling a clock. One read tells you idle vs in-flight vs scheduled.

Inputs: device_id (required).

ramp_crestron_deviceA

Smoothly ramp (fade) an ANALOG device to a value over a duration. Use for requests like "fade the lounge lights to 50% over 3 seconds". Optionally start the fade after delay_ms ("fade down in 30 seconds, over 2 seconds"). Analog devices only; digital and serial devices don't ramp - use control_crestron_device for those (and for an instant analog set).

Inputs: device_id (required), value (required), duration_ms (required), delay_ms.

set_crestron_devicesA

Apply a scene/macro: set many devices in one call. Each entry can optionally fade (duration_ms, analog only - the device ramps to value instead of snapping) and/or start after a wait (delay_ms). Use for "movie night" (fade lights down over 2s + lower screen + projector on) or staged sequences. Values follow control_crestron_device rules (digital/analog/serial). A plain (no-timing) value may contain colons but not commas.

Inputs: assignments (required).

start_crestron_trialA

Start a free 7-day trial on this processor - no payment, no card, nothing for the user to paste. Use it when the processor is unlicensed, or when a trial has lapsed and the user wants to keep going. Each processor gets up to 3 one-week trials; this reports trials_remaining and the expiry after starting one. When the trials are used up it returns a buy link instead. The underlying AV keeps working regardless; licensing only gates this natural-language layer.

Inputs: no named parameters.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    TDQS

    A3.9/5.0

    Scored across 14 tools

    Disambiguation5/5

    Each tool targets a distinct operation: licensing (activate/check/start trial), device control (control/pulse/ramp/cancel), batch control (set), querying (query, get_room_status, list, discover), and system info (get time). No two tools have overlapping purposes; agents can easily distinguish when to use which.

    Naming Consistency4/5

    Most tools follow a verb_crestron_device or verb_crestron_system pattern, with consistent snake_case. The only minor deviation is 'get_room_status' instead of 'get_crestron_room_status', but it's a single outlier and still clear.

    Tool Count5/5

    14 tools are well-scoped for a Crestron control system: licensing (3 tools), device control (5: control, pulse, ramp, cancel, set), information (5: discover, list rooms, list devices, get room status, query device), and utility (1: get time). This covers all core operations without bloat.

    Completeness4/5

    The set covers the full lifecycle: discover, list, query, control (single & batch), ramp, pulse, cancel, and licensing management. Minor gaps like a 'stop all devices' or 'reset device' are absent but not essential for typical agent workflows. Overall highly complete.

    Maintenance

    ActivityMaintained
    ResponsivenessLimited data

    Related MCP Connectors

    Related MCP Servers