starccm-mcp
Server Configuration
Describes the environment variables required to run the server.
| Name | Required | Description | Default |
|---|---|---|---|
| STARCCM_HOME | No | The folder that contains `star\` and `doc\`. Only needed if the STAR-CCM+ installation is somewhere other than `C:\Program Files\Siemens\*\STAR-CCM+*`. |
Instructions
Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.
Tools for Simcenter STAR-CCM+. starccm_sim_* read .sim files without a licence; starccm_log_* read solver logs; starccm_docs_* and starccm_api_lookup search the local documentation; starccm_session_* and starccm_run_macro act on a running simulation. Before any macro: run starccm_session_info, check every API call with starccm_api_lookup, and ask the user before setting allow_risky.
Capabilities
Features and capabilities supported by this server
Protocol revision2025-11-25
| Capability | Details |
|---|---|
| tools | {
"listChanged": false
} |
| prompts | {
"listChanged": false
} |
| resources | {
"subscribe": false,
"listChanged": false
} |
Tools
Functions exposed to the LLM to take actions
| Name | Description |
|---|---|
| starccm_sim_overviewA | Summary of a STAR-CCM+ .sim file read directly from disk, without STAR-CCM+ or a licence. Returns JSON with: STAR-CCM+ version that saved it, current iteration, volume mesh size (cells, faces, vertices), regions, number of boundaries, physics continua with their models, global parameters, reports, monitors, mesh operations, scenes, stopping criteria (used/satisfied and their limits) and the last save-history entries. Start here, then use starccm_sim_parameters, starccm_sim_boundaries, starccm_sim_monitors or starccm_sim_object for details. The file is never modified. |
| starccm_sim_parametersA | Global parameters (Tools > Parameters) of a .sim file: name, definition, stored value and units. Note: the stored value of an expression is the last one STAR-CCM+ evaluated; after an edit that was not re-evaluated it can be stale. The definition is always the current one. |
| starccm_sim_boundariesB | Boundary types and physics values of every boundary in a .sim file. For each boundary: region, name, type (e.g. FreeStreamBoundary, WallBoundary, StagnationBoundary),
selected options and the active values with method, definition, value and units (e.g. Mach number
'${Minlet}' = 0.8). Options are stored as indices (options_selected_index). When the local Java API
reference is available, |
| starccm_sim_monitorsA | Residual and report monitors stored in a .sim file. Without |
| starccm_sim_findA | Finds objects in a .sim file by name, class or raw text. Returns record numbers for starccm_sim_object. |
| starccm_sim_objectA | All settings of one object (report, mesh operation, physics model, solver, criterion...). References are resolved: quantities show value, units and definition; options show the selected index;
other objects show their name and class, expanded to |
| starccm_log_summaryA | Parses a STAR-CCM+ output log: iteration table and solver events. Returns the column names, the first and last iteration rows, grouped events with counts and the first and last iteration where they happened (AMG divergence, reversed flow, limited cells, errors, warnings, stopping criteria, saves) and the last lines of text. Licence keys and servers are masked. |
| starccm_log_tailA | Last lines of a STAR-CCM+ log, optionally filtered. Licence keys and servers are masked. |
| starccm_docs_searchA | Searches the HTML user guide installed with STAR-CCM+ (built into a local index on first use, a few seconds). Returns page ids, titles and a snippet; read a page with starccm_docs_page. |
| starccm_docs_pageB | Plain text of one page of the local user guide, paginated with offset/max_chars. |
| starccm_api_lookupA | Checks a class or method against the local Java API reference before writing a macro: package, inheritance, exact signatures (following inherited methods to the class that declares them), or a list of similar class names when the name is wrong. |
| starccm_session_listA | Running STAR-CCM+ servers on this machine (Windows): port, server process, start time, connected clients and, when a GUI is connected, the simulation name from its window title. Licence data is never returned. |
| starccm_session_infoA | Runs a built-in read-only macro on the server at localhost: and returns the simulation name and path, workers, current iteration, regions and boundaries with types, continua and models, global parameters (definition, value, units), reports, monitors and scenes. It takes some seconds because a batch client has to start. Use it to confirm which simulation is open before running any other macro. |
| starccm_run_macroA | Runs a Java macro on the STAR-CCM+ server at localhost: through a batch client. The server, its GUI and the open simulation stay running; on timeout only the batch client is killed. Before running, the source is checked against patterns. Refused: Java reflection, class loading, System.exit/getenv, Runtime and processes, network and script engines (a reflective read-only macro once crashed a parallel server when it reached unloaded 3D-CAD sketches). Refused unless allow_risky=True: 3D-CAD access, saveState, deleting or clearing objects and data, closing the simulation, running the solver, meshing, and writing files. These checks catch mistakes; they are not a sandbox, and a macro that runs has the user's full rights. Good practice: call starccm_session_info first; verify every class and method with starccm_api_lookup;
write simple macros like the ones STAR-CCM+ records; print results with sim.println(...), and prefix
lines with 'MCP|' to get them back in |
Prompts
Interactive templates invoked by user choice
| Name | Description |
|---|---|
No prompts | |
Resources
Contextual data attached and managed by the client
| Name | Description |
|---|---|
No resources | |
TDQS
Scored across 14 tools
Most tools target distinct resources: sim_* readers split cleanly by aspect (overview, parameters, boundaries, monitors, find, object), and log/docs/session tools are separate domains. There is mild overlap because starccm_sim_overview already summarizes parameters, boundaries and monitors that the dedicated tools return in detail, and starccm_sim_object can return any of them too, but the descriptions explicitly steer (start with overview, then drill down), which resolves most confusion. session_list vs session_info is clearly distinguished by list-vs-inspect.
Every tool shares the starccm_ prefix and snake_case, grouped by domain (sim_, log_, docs_, session_). Minor deviation: the sim readers are noun-only (starccm_sim_overview, starccm_sim_boundaries) while other tools are verb-led (starccm_sim_find, starccm_docs_search, starccm_run_macro), so it is not a uniform verb_noun pattern. Still highly predictable and readable.
14 tools is well within the ideal range and each group earns its place: 6 read-only .sim inspectors, 2 log tools, 2 doc-guide tools, 1 API reference checker, and 3 session/macro tools. Nothing feels redundant or missing at the count level.
The surface covers the full read/inspect lifecycle for .sim files, logs, documentation, API verification and live session discovery, and starccm_run_macro is an escape hatch for arbitrary actions. Gaps remain: no direct write tools (e.g. set a parameter or boundary value without writing a Java macro), no explicit solver/mesh control tool, and no session attach/save operations, though these are reachable through macros.