Skip to main content
Glama
NemoN

PLENTICORE MCP

by NemoN

Server Configuration

Describes the environment variables required to run the server.

NameRequiredDescriptionDefault
PLENTICORE_URLYesBase URL of the KOSTAL PLENTICORE inverter without /api/v1, e.g. http://plenticore.example
PLENTICORE_TIMEOUTNoTimeout in seconds for inverter API requests.
PLENTICORE_PASSWORDYesPlant owner password from the inverter's local web interface.
PLENTICORE_READ_ONLYNoWhen true, blocks settings writes while allowing previews. If omitted, the code default is false.false
PLENTICORE_VERIFY_SSLNoWhether to verify SSL certificates for HTTPS connections.

Instructions

Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.

This server publishes no instructions, or was last inspected before Glama recorded them.

Capabilities

Features and capabilities supported by this server

Protocol revision2025-11-25

CapabilityDetails
tools
{
  "listChanged": false
}
prompts
{
  "listChanged": false
}
resources
{
  "subscribe": false,
  "listChanged": false
}

Tools

Functions exposed to the LLM to take actions

NameDescription
plenticore_batteryA

Read available battery measurements, including SoC and power.

plenticore_energyB

Read inverter-native energy counters for Day, Month, Year or Total. Preserve units.

plenticore_eventsA

Read the latest 1–100 inverter events; active events may have end_time=null.

plenticore_list_modulesA

Discover the modules actually offered by this inverter and current user.

plenticore_list_process_dataB

Discover measurement IDs. Search module/ID; follow next_offset for more.

plenticore_list_settingsB

Discover setting types, units, access rights and min/max. Secrets are omitted.

plenticore_overviewB

Read power flow, AC, PV strings, battery and meter measurements that exist.

plenticore_read_process_dataA

Read explicit {moduleid: [IDs]} (max 200), returning native values and units.

plenticore_read_settingsA

Read explicit {moduleid: [setting IDs]}. Discover IDs first; secrets are excluded.

plenticore_statusA

Read API/firmware version and plant owner session status.

plenticore_update_settingsA

Preview settings changes; dry_run=false writes and reads back. Values are strings.

Uses actual owner-accessible IDs, types and min/max. No installer login. Read list_settings and the current values first. Multi-setting writes are not atomic; no automatic rollback. A connection error after submission can leave a change applied: read back before retrying.

Prompts

Interactive templates invoked by user choice

NameDescription

No prompts

Resources

Contextual data attached and managed by the client

NameDescription
usageMeasurement interpretation and settings workflow.

TDQS

A3.6/5.0

Scored across 11 tools

Disambiguation4/5

The list_* discovery tools are clearly separated from the read_* tools by description (discover IDs vs read explicit IDs), and battery/energy/events/status each target distinct data. The only soft overlap is plenticore_overview, which aggregates battery, PV, meter and AC readings that plenticore_battery and plenticore_energy also expose, so an agent may occasionally choose overview redundantly.

Naming Consistency4/5

All names use a consistent plenticore_ prefix with snake_case, and the list_/read_/update_ verb pattern is applied predictably to processes and settings. The single-word resource reads (battery, energy, events, overview, status) deviate from the verb_noun pattern but remain unambiguous.

Tool Count5/5

Eleven tools is well within the ideal range for an inverter integration and each earns its place: discovery, targeted reads, an aggregate overview, and a single guarded write path. Nothing appears padded or redundant enough to be dropped.

Completeness4/5

The surface covers discovery, reads of measurements/energy/events/status, and settings read plus a dry-run-first write, which is a full lifecycle for this domain. Minor gaps exist: no process-data write, no setting pagination noted, and no explicit way to acknowledge or clear events, though these may be limitations of the inverter API.

Maintenance

ActivityMaintained
ResponsivenessNo issues