# MCP PLC Core šŸ­

**Universal MCP Server for industrial PLC communication — works with ANY PLC.**

Connect any industrial controller to AI agents (Claude, GPT, OpenClaw) via MCP protocol. Siemens, Schneider, ABB, Mitsubishi, Omron, Allen-Bradley, WAGO, CODESYS, Arduino, ESP32, or any custom PLC — write an adapter and it just works.

> **Don't see your PLC?** Write an adapter — takes 15 minutes. Just implement 6 methods in the `PLCAdapter` interface.

```
AI Agent (Claude, GPT, OpenClaw)
    ↓ MCP protocol (stdio)
MCP PLC Core
    ↓ your adapter (Modbus, S7, OPC UA, EtherNet/IP...)
PLC → Sensors, Alarms, Motors, Actuators
```

## Quick Start

```bash
# Install
npm install mcp-plc-core

# Schneider / ABB / WAGO / CODESYS / Arduino
PLC_HOST=192.168.1.100 npx mcp-plc --adapter modbus

# Siemens S7-1200/1500/300/400
npm install nodes7
PLC_HOST=192.168.1.100 npx mcp-plc --adapter s7

# Mitsubishi / Omron / Allen-Bradley / anything else
npx mcp-plc --adapter ./my-custom-adapter.js
```

## Built-in Adapters

| Adapter | Protocol | Port | PLC Types |
|---------|----------|------|-----------|
| `modbus` | Modbus TCP | 502 | Schneider, ABB, WAGO, CODESYS, Arduino |
| `s7` | S7 (RFC1006) | 102 | Siemens S7-1200/1500/300/400 |

## Custom Adapter — Works with ANY PLC

Implement the `PLCAdapter` interface for your PLC. Regardless of manufacturer, protocol, or model — if it has TCP/IP or serial connectivity, you can write an adapter.

**PLCs you can write adapters for:**
- Siemens S7-200/300/400/1200/1500/1700
- Schneider M340/M580/Modicon
- ABB AC500/AC580
- Mitsubishi MELSEC iQ-R/F/L
- Omron NJ/NX/NP
- Allen-Bradley ControlLogix/CompactLogix
- WAGO PFC200/750
- CODESYS-based controllers
- Bosch Rexroth IndraMotion
- Beckhoff TwinCAT
- Fanuc CNC (FOCAS)
- Haas / DMG Mori / Mazak
- Arduino + EthernetShield
- ESP32 + Modbus/S7 gateway
- Any custom TCP/UDP protocol

```typescript
import { PLCAdapter, SensorData, AlarmData, StatusData, SetpointData, OutputData } from "mcp-plc-core";

export class MyPLCAdapter implements PLCAdapter {
  readonly name = "My PLC";
  readonly protocol = "my-protocol";

  async connect() { /* ... */ }
  async disconnect() { /* ... */ }
  isConnected(): boolean { /* ... */ }

  async readSensors(): Promise<SensorData> {
    return {
      temperature: 25.3,
      pressure: 6.2,
      motorSpeed: 1500,
      production: 1234,
    };
  }

  async readAlarms(): Promise<AlarmData> {
    return { active: [], count: 0 };
  }

  async readStatus(): Promise<StatusData> {
    return { status: "running" };
  }

  async readSetpoints(): Promise<SetpointData> {
    return { temperature: 25, pressure: 6, speed: 1500 };
  }

  async readOutputs(): Promise<OutputData> {
    return { green: true, yellow: false, red: false };
  }

  async writeSetpoint(parameter: string, value: number): Promise<boolean> {
    // Write to your PLC...
    return true;
  }
}
```

Then use it:

```typescript
import { startServer, MyPLCAdapter } from "mcp-plc-core";

const adapter = new MyPLCAdapter();
await startServer({
  adapter,
  limits: {
    temperature: { min: 0, max: 50 },
    pressure: { min: 0, max: 10 },
  },
});
```

## MCP AI Integration

### Claude Desktop / OpenClaw

```json
{
  "mcpServers": {
    "plc": {
      "command": "npx",
      "args": ["mcp-plc", "--adapter", "modbus"],
      "env": {
        "PLC_HOST": "192.168.1.100",
        "PLC_PORT": "502"
      }
    }
  }
}
```

### Siemens S7

```json
{
  "mcpServers": {
    "plc": {
      "command": "npx",
      "args": ["mcp-plc", "--adapter", "s7"],
      "env": {
        "PLC_HOST": "192.168.1.100",
        "PLC_SLOT": "1"
      }
    }
  }
}
```

## Tools

| Tool | Description | Example |
|------|-------------|---------|
| `read_sensor` | Read sensor value | "What's the temperature?" |
| `get_alarms` | Get active alarms | "Any alarms active?" |
| `get_status` | Full system status | "How's the line running?" |
| `get_setpoints` | Current setpoints | "What are the setpoints?" |
| `write_setpoint` | Write setpoint (safe!) | "Set temperature to 35°C" |
| `get_all` | Everything at once | "Give me all data" |

## Resources

| Resource | Description |
|----------|-------------|
| `plc://tags` | Available sensors/tags |
| `plc://alarms` | Alarm definitions |
| `plc://status` | Current status |
| `plc://info` | PLC and adapter info |

## Safety

- āœ… **Read-only by default** — no writes without explicit tool call
- āœ… **Safety limits** — configurable min/max for setpoints
- āœ… **Audit logging** — all tool calls logged
- āœ… **Adapter isolation** — protocol-specific errors don't leak
- āš ļø **Write protection** — only setpoint registers, never I/O directly

## Architecture

```
src/
ā”œā”€ā”€ adapter.ts          ← PLCAdapter interface (implement this)
ā”œā”€ā”€ server.ts           ← MCP server (generic, adapter-agnostic)
ā”œā”€ā”€ cli.ts              ← CLI entry point
ā”œā”€ā”€ index.ts            ← Package exports
└── adapters/
    ā”œā”€ā”€ modbus.ts       ← Modbus TCP adapter (built-in)
    └── s7.ts           ← Siemens S7 adapter (built-in)
```

## Writing a New Adapter

6 methods. 15 minutes. Works with any PLC.

1. Create `src/adapters/myplc.ts`
2. Implement `PLCAdapter` interface (6 methods)
3. Register in `cli.ts`:

```typescript
if (adapterName === "myplc") {
  const { MyPLCAdapter } = await import("./adapters/myplc.js");
  return new MyPLCAdapter({ host, port });
}
```

4. Submit PR! šŸŽ‰

## Supported Protocols (via adapters)

| Protocol | Status | Adapter |
|----------|--------|---------|
| Modbus TCP | āœ… Built-in | `modbus` |
| S7 (RFC1006) | āœ… Built-in | `s7` |
| OPC UA | āœ… Via community | [node-opcua](https://github.com/node-opcua/node-opcua) |
| EtherNet/IP | āœ… Via community | [ethernetip](https://github.com/nicedoc/ethernetip) |
| BACnet | āœ… Via community | [bacstack](https://github.com/nicedoc/bacstack) |
| MQTT + Sparkplug B | āœ… Via community | [mqtt](https://github.com/mqttjs/MQTT.js) |
| Mitsubishi MC Protocol | šŸ”Ø Community needed | — |
| Omron FINS | šŸ”Ø Community needed | — |
| Allen-Bradley CIP | šŸ”Ø Community needed | — |
| Bosch Rexroth | šŸ”Ø Community needed | — |
| Fanuc FOCAS | šŸ”Ø Community needed | — |
| Haas NGC | šŸ”Ø Community needed | — |
| Any custom TCP/UDP | āœ… Adapter interface | `PLCAdapter` |

**Don't see your protocol?** Implement `PLCAdapter` — 6 methods, 15 minutes of work. Submit a PR and it'll be in the next release.

## Environment Variables

| Variable | Default | Description |
|----------|---------|-------------|
| `PLC_HOST` | `127.0.0.1` | PLC IP address |
| `PLC_PORT` | varies | PLC port (502 for Modbus, 102 for S7) |
| `PLC_ADAPTER` | `modbus` | Adapter to use |
| `PLC_RACK` | `0` | Rack number (S7 only) |
| `PLC_SLOT` | `1` | Slot number (S7: 1, S7-300/400: 2) |

## License

MIT — use it, fork it, build adapters for your PLC.

---

**HD WebDesign** — MCP for industrial automation

TDQS

B3.2/5.0

Scored across 6 tools

Disambiguation4/5

Tools are mostly distinct: read_sensor, get_alarms, get_status, get_setpoints, and write_setpoint each target a specific domain area. The main overlap is get_all, which subsumes the individual getters, potentially confusing an agent about whether to call it or individual tools, though descriptions make the distinction reasonably clear.

Naming Consistency4/5

Naming follows a consistent verb_noun pattern: read_sensor, get_alarms, get_status, get_setpoints, write_setpoint, get_all. Minor inconsistency exists with 'read' vs 'get' for data retrieval (read_sensor uses read while others use get), but this is a small deviation and the pattern is otherwise uniform.

Tool Count5/5

Six tools is a well-scoped set for a PLC control server, covering the essential read and write operations without bloat. Each tool serves a clear purpose, and the count is appropriate for the domain.

Completeness4/5

The surface covers reading sensors, alarms, status, and setpoints, plus writing setpoints with safety validation. Notably missing are operations for controlling outputs (writing discrete/analog output values) and acknowledging alarms, which are common PLC tasks. However, get_all consolidates reads, and setpoint writing is the safety-relevant write path.