Skip to main content
Glama

update_heating_mode_settings

Update permanent configuration settings for a ZONT heating mode, including hysteresis and maximum modulation level, by providing the device, mode, and fields to change.

Instructions

Изменить настройки режима отопления (постоянная правка конфигурации).

Параметры: device_id: идентификатор устройства. mode_id: идентификатор режима (из get_config → heating_modes). settings: поля для изменения, например: {"hysteresis": 1, "max_modulation_level": 40}

Температуры зон режима задаются ссылками (setting_register); для смены целевой температуры режима удобнее кабинет — здесь меняются числовые параметры самого режима.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "device_id": "<device_id>",
      "mode_id": "<mode_id>",
      "settings": "<settings>"
    },
    "name": "update_heating_mode_settings"
  }
}

Input Schema

NameRequiredDescriptionDefault
mode_idYes
settingsYes
device_idYes

Output Schema

NameRequiredDescriptionDefault
resultYes

Schema Changelog

Changes observed during successful MCP inspections.

  1. First observedv1.3.2

TDQS

A4.2/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

With no annotations, the description carries the full burden and does disclose the key behavioral trait: this is a permanent config mutation, not a transient override, which is exactly the distinction an agent needs before writing. It omits whether unspecified settings are preserved, whether the call is reversible, and any validation or error behavior.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The purpose sentence is front-loaded ahead of the parameter block, and the example is high-value rather than padding. The trailing note on zone temperatures is slightly loose in wording but earns its place by preventing a wrong call.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

The output schema means return values need not be explained, and the mutation scope is clear. The real gap is the unconstrained settings object: with 0% schema coverage and only two example fields, an agent cannot reliably know what keys are accepted or how types are validated.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 0%, so the description must compensate and largely does: it explains all three parameters, gives mode_id's provenance, and shows a concrete settings example with real keys (hysteresis, max_modulation_level). Since settings is a free-form object with additionalProperties, the example is illustrative rather than exhaustive, leaving valid keys discoverable only by guessing.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a specific verb and resource ('Изменить настройки режима отопления') and immediately scopes it as a permanent configuration edit, which distinguishes it from the temporary-mode family (set_temporary_heating_mode, reset_temporary_heating_mode). It further separates itself from update_mode_temperatures by saying target temperatures belong elsewhere.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines4/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Explicitly says where mode_id comes from ('из get_config → heating_modes') and steers the agent away from this tool for target temperatures ('удобнее кабинет'), which is an actionable exclusion. It stops short of naming the sibling tools it is contrasted with and gives no prerequisites or permission notes.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.