Skip to main content
Glama
README.md
<div align="center">

# 🏭 OPC UA MCP Server

**Connect Claude, Codex, Gemini and any other MCP agent to machines over OPC UA.<br>
Read live data, watch for alarms and, only when you allow it, control equipment.**

[![npm version](https://img.shields.io/npm/v/opcua-mcp-server)](https://www.npmjs.com/package/opcua-mcp-server)
[![PyPI version](https://img.shields.io/pypi/v/opcua-mcp-server)](https://pypi.org/project/opcua-mcp-server/)
[![npm downloads](https://img.shields.io/npm/dm/opcua-mcp-server)](https://www.npmjs.com/package/opcua-mcp-server)
[![CI](https://github.com/IndustriAgents/OPCUA-MCP/actions/workflows/ci.yml/badge.svg)](https://github.com/IndustriAgents/OPCUA-MCP/actions/workflows/ci.yml)
[![MCP](https://img.shields.io/badge/MCP-compatible-purple)](https://modelcontextprotocol.io)
[![License: MIT](https://img.shields.io/github/license/IndustriAgents/OPCUA-MCP)](LICENSE)

[Watch the demo](#see-it-in-action) · [Quick start](#quick-start) · [Try it without hardware](#try-it-without-hardware) · [Connect your agent](#connect-your-agent) · [Tools](#tools) · [Safety](#safety-and-production) · [Docs](#documentation)

[Official MCP Registry](https://registry.modelcontextprotocol.io/?q=io.github.midhunxavier%2Fopcua) · [Glama](https://glama.ai/mcp/servers/IndustriAgents/OPCUA-MCP) · [HardwareMCP](https://hardwaremcp.khanex.ai/servers/industriagents-opcua-mcp/)

</div>

## See it in action

https://github.com/user-attachments/assets/2e1e9898-d942-41f6-bcc2-88e1a7ef1936

In this 3-minute demo, Claude watches a conveyor running in the free
[Prosys OPC UA Simulation Server](https://prosysopc.com/products/opc-ua-simulation-server/).
It reads the live values, checks the conveyor every minute on its own, reports
an overheat alarm with a suggested fix, and lowers the speed only after you
approve it. When asked for more than the allowed limit, it refuses. Codex
connects to the same server with one command.

## What it does

| | |
|---|---|
| 📖 **Read** | Browse the plant and read live values, history and events. Every value comes with its data type, quality, timestamps and unit ([example](docs/tools.md#what-comes-back)). |
| 👀 **Monitor** | Subscribe to values and events. The agent collects every change since it last looked. |
| 🚨 **Alarms** | List active alarms and, when you allow it, acknowledge them. |
| 🎛️ **Control** | Write setpoints and call methods, but only on targets you allowlist, within the limits you set, with every call written to an audit log. |

- **Any OPC UA server:** PLC, SCADA gateway, historian or simulator. Nothing to install on the plant side.
- **Any MCP agent:** Claude Code, Claude Desktop, Codex, Gemini CLI, Antigravity, Cursor, VS Code, Windsurf and more.
- **Node or Python:** two runtimes with the same tools. Use whichever you have.
- **Read-only by default:** control needs an explicit profile and a secured, verified connection.

```mermaid
flowchart LR
    A["AI agent<br/>(Claude, Codex, Gemini, Cursor…)"] -->|MCP| B["OPC UA MCP Server<br/>(Node or Python)"]
    B -->|OPC UA| C["Machine<br/>(PLC / SCADA / historian / simulator)"]
```

Your agent starts the server as a local process (MCP over stdio). One process
talks to one OPC UA endpoint, so add one entry per server
([why](docs/configuration.md#one-process-one-endpoint)). Remote and shared
multi-client use is planned in the
[identity and isolation RFC](docs/rfc/0001-remote-identity-isolation.md).

## Quick start

**1. Check that it runs.** You need Node.js **22.13+** *or* Python **3.10+**
with [uv](https://docs.astral.sh/uv/getting-started/installation/). Pick one:

```bash
npx -y opcua-mcp-server --version   # Node
uvx opcua-mcp-server --version      # Python
```

It prints a version and exits. You don't start the server yourself after that:
your agent launches it. No Node or Python? Use the
[Claude Desktop bundle](#claude-desktop-bundle) or a
[single-file executable](docs/install.md#2-single-file-executable--no-runtime-at-all).

**2. Add it to your agent**, with your OPC UA server's endpoint. For Claude Code:

```bash
claude mcp add opcua -e OPCUA_SERVER_URL=opc.tcp://localhost:4840/freeopcua/server/ -- npx -y opcua-mcp-server
```

For Codex:

```bash
codex mcp add opcua --env OPCUA_SERVER_URL=opc.tcp://localhost:4840/freeopcua/server/ -- npx -y opcua-mcp-server
```

Replace the URL with your server's endpoint, and `npx -y opcua-mcp-server` with
`uvx opcua-mcp-server` for Python. Other agents: [Connect your agent](#connect-your-agent).
No OPC UA server yet? [Try it without hardware](#try-it-without-hardware).

**3. Ask.** Restart your agent or start a new session (approve the `opcua` server if it asks), then try:

- *"Check the OPC UA connection."*
- *"Browse the server and read the current values."*
- *"Watch the temperature for a minute and tell me what it does."*

A working connection reports `connected: true`. If it fails, check that the OPC
UA server is running and that `OPCUA_SERVER_URL` matches its endpoint, then see
[troubleshooting](docs/testing.md#troubleshooting).

## What you can ask

- *"What's the status of the line?"*
- *"What was the temperature over the last hour? Give me the hourly average."*
- *"What alarms are active right now?"*
- *"When did the motor temperature start rising? Check its history."*
- *"Set the valve position to 80%."* (needs the `operator` profile)

**Let the agent watch on its own.** The server keeps every change it sees, and
the agent reads them when it checks. To have it check on a schedule, use your
agent's scheduler. In Claude Code, for example:

```text
/loop 1m Watch Conveyor 1. If the overheat alarm turns on, tell me what happened and suggest a fix.
```

What works depends on the server: history needs historical access, server-side
averages need aggregates, and active alarms need Alarms & Conditions. Writes and
method calls need the `operator` profile, allowlisted targets and a secured
connection ([Safety](#safety-and-production)).

## Try it without hardware

**Prosys OPC UA Simulation Server.** A free desktop app for Windows, macOS and
Linux from [Prosys OPC](https://prosysopc.com/products/opc-ua-simulation-server/),
used in the demo above. Start it and copy the connection address from its
**Status** tab, for example `opc.tcp://localhost:53530/OPCUA/SimulationServer`.
Every scenario in our [compatibility tests](docs/compatibility.md) passed
against it on both runtimes.

**The simulated plant in this repository.** Needs Git, Python 3.10+ and uv,
even if you use the Node server:

```bash
git clone https://github.com/IndustriAgents/OPCUA-MCP.git
cd OPCUA-MCP
uv sync --all-packages
uv run --no-sync opcua-mock-server
```

Wait for `Server is running and ready for connections`, keep the terminal open,
and use `opc.tcp://localhost:4840/freeopcua/server/` as the endpoint.

![An AI agent asks about the line's sensors, calls browse_opcua_nodes, read_opcua_nodes and read_opcua_history on the simulated plant, and answers from the values returned](docs/assets/demo.gif)

<sub>Every tool call and value above is a real response from the bundled simulator,
recorded through the Python bridge under the read-only `observe` profile; the
question and answer text are scripted. Rebuild it with
[`scripts/readme_demo.py`](scripts/readme_demo.py).</sub>

<details>
<summary>What the simulated plant covers, and the extra mocks</summary>

The plant supports browsing, sensor reads, data-change subscriptions, raw value
history, plain events and event history. It also has writable actuators and
methods, subject to the server's control policy. It does **not** implement
processed aggregates or Alarms & Conditions. Use the separate mocks for those:

| Mock | Endpoint | Coverage |
|---|---|---|
| [Plant](packages/mock-server/README.md) | `opc.tcp://localhost:4840/freeopcua/server/` | Sensors, actuators, methods, raw history, subscriptions and plain events |
| [Aggregates](packages/mock-server-aggregate/README.md) | `opc.tcp://localhost:4841/UA/Aggregate` | Processed history, such as average buckets |
| [Alarms](packages/mock-server-alarms/README.md) | `opc.tcp://localhost:4842/UA/Alarms` | Active conditions and acknowledgement |

The separate mocks need Node and npm; their READMEs give the commands. If port
4840 is busy, start the plant with
`uv run --no-sync opcua-mock-server --endpoint opc.tcp://127.0.0.1:14840/freeopcua/server/`
and use that URL instead. The [MCP Inspector walkthrough](docs/testing.md) has
more examples.

</details>

## Connect your agent

Pick your agent below. The examples use the simulated plant's endpoint; replace
`opc.tcp://localhost:4840/freeopcua/server/` with yours. For Python, use
`"command": "uvx"` and `"args": ["opcua-mcp-server"]` in JSON, or
`command = "uvx"` and `args = ["opcua-mcp-server"]` in TOML. For a secure
connection, add the settings from [Safety](#safety-and-production) to the same
`env` block.

<a id="claude-desktop-bundle"></a>

<details>
<summary><b>Claude Desktop</b></summary>

**Easiest — the bundle.** Download `opcua-mcp-server-<version>.mcpb` from the
[latest release](https://github.com/IndustriAgents/OPCUA-MCP/releases/latest),
drag it into **Settings → Extensions**, and fill in **OPC UA endpoint**. No
Node, no Python, no JSON.

![OPC UA MCP Server in Claude Desktop](docs/assets/screenshot.png)

**Or let the server write the config** (needs Node or Python):

```bash
npm install -g opcua-mcp-server      # or: uv tool install opcua-mcp-server
opcua-mcp-server --install claude-desktop --url opc.tcp://localhost:4840/freeopcua/server/ --dry-run
```

It checks the config with the server's own startup validation and writes absolute
paths, because Claude Desktop does not inherit your shell's `PATH`. The profile
defaults to read-only; encryption, a pinned server certificate, a control profile,
a policy file and an audit file are all flags, and passwords are never taken as
flags. Check the preview, then repeat the command without `--dry-run` to write
the configuration and restart Claude Desktop. Every flag and safety rule, editing
`claude_desktop_config.json` by hand, and fixing a server that fails to start:
[docs/install.md](docs/install.md#3---install--let-the-server-write-the-config).

</details>

<details>
<summary><b>Claude Code</b></summary>

```bash
claude mcp add opcua -e OPCUA_SERVER_URL=opc.tcp://localhost:4840/freeopcua/server/ -- npx -y opcua-mcp-server
```

Add `--scope project` to share it with your team through `.mcp.json`.

</details>

<details>
<summary><b>OpenAI Codex</b></summary>

```bash
codex mcp add opcua --env OPCUA_SERVER_URL=opc.tcp://localhost:4840/freeopcua/server/ -- npx -y opcua-mcp-server
```

Or add it to `~/.codex/config.toml`:

```toml
[mcp_servers.opcua]
command = "npx"
args = ["-y", "opcua-mcp-server"]
env = { OPCUA_SERVER_URL = "opc.tcp://localhost:4840/freeopcua/server/" }
```

Or let the server write that entry, with the same checks as for Claude Desktop:
`opcua-mcp-server --install codex --url opc.tcp://localhost:4840/freeopcua/server/ --dry-run`.
This installer command requires a permanent package installation first:
`npm install -g opcua-mcp-server` or `uv tool install opcua-mcp-server`.
Check the preview and repeat without `--dry-run` to write it.

</details>

<details>
<summary><b>Gemini CLI</b></summary>

Add to `~/.gemini/settings.json`, or `.gemini/settings.json` in a project:

```json
{
  "mcpServers": {
    "opcua": {
      "command": "npx",
      "args": ["-y", "opcua-mcp-server"],
      "env": { "OPCUA_SERVER_URL": "opc.tcp://localhost:4840/freeopcua/server/" }
    }
  }
}
```

</details>

<details>
<summary><b>Google Antigravity</b></summary>

In the agent panel, open **⋯ → MCP Servers → Manage MCP Servers → View raw
config**, add the entry below to `mcp_config.json`, and restart Antigravity:

```json
{
  "mcpServers": {
    "opcua": {
      "command": "npx",
      "args": ["-y", "opcua-mcp-server"],
      "env": { "OPCUA_SERVER_URL": "opc.tcp://localhost:4840/freeopcua/server/" }
    }
  }
}
```

</details>

<details>
<summary><b>Cursor</b></summary>

Add to `~/.cursor/mcp.json`, or `.cursor/mcp.json` in a project:

```json
{
  "mcpServers": {
    "opcua": {
      "command": "npx",
      "args": ["-y", "opcua-mcp-server"],
      "env": { "OPCUA_SERVER_URL": "opc.tcp://localhost:4840/freeopcua/server/" }
    }
  }
}
```

</details>

<details>
<summary><b>VS Code (GitHub Copilot)</b></summary>

Add to `.vscode/mcp.json` — note the top-level key is `servers`:

```json
{
  "servers": {
    "opcua": {
      "type": "stdio",
      "command": "npx",
      "args": ["-y", "opcua-mcp-server"],
      "env": { "OPCUA_SERVER_URL": "opc.tcp://localhost:4840/freeopcua/server/" }
    }
  }
}
```

</details>

<details>
<summary><b>Windsurf</b></summary>

Add to `~/.codeium/windsurf/mcp_config.json`:

```json
{
  "mcpServers": {
    "opcua": {
      "command": "npx",
      "args": ["-y", "opcua-mcp-server"],
      "env": { "OPCUA_SERVER_URL": "opc.tcp://localhost:4840/freeopcua/server/" }
    }
  }
}
```

</details>

<details>
<summary><b>Any other MCP client</b></summary>

Most clients accept this `mcpServers` entry. The server speaks MCP over stdio.

```json
{
  "mcpServers": {
    "opcua": {
      "command": "npx",
      "args": ["-y", "opcua-mcp-server"],
      "env": { "OPCUA_SERVER_URL": "opc.tcp://localhost:4840/freeopcua/server/" }
    }
  }
}
```

</details>

> [!TIP]
> **No Node or Python on the machine?** Download a single-file executable from the
> [latest release](https://github.com/IndustriAgents/OPCUA-MCP/releases/latest)
> and use its path as the `command` — see [docs/install.md](docs/install.md).
> **Several PLCs?** Each entry talks to one endpoint, so add one entry per PLC
> ([why](docs/configuration.md#one-process-one-endpoint)).

## Tools

<!-- BEGIN GENERATED: tool-summary from contract/tools.json by packages/server-node/scripts/config-artifacts.mjs. Do not edit by hand: edit the source, then run `npm run config:generate` in packages/server-node. -->

**15 tools**, identical on both runtimes and defined once in [`contract/tools.json`](contract/tools.json). Arguments, results and limits: [docs/tools.md](docs/tools.md).

| Access | Offered under | Tools |
|---|---|---|
| **read** | every profile, including the default `observe` | `read_opcua_nodes` · `browse_opcua_nodes` · `read_opcua_history` † · `read_event_history` † · `get_server_status` · `list_subscriptions` · `list_active_alarms` |
| **monitor** | every profile, including the default `observe` | `subscribe_opcua_nodes` · `unsubscribe_opcua_nodes` · `subscribe_events` · `read_events` |
| **alarm-action** | `operator` with `OPCUA_ALLOW_ACKNOWLEDGE_ALARMS`, or `full` | `acknowledge_alarm` · `act_on_alarm` |
| **control** | `operator`, for allowlisted targets only, or `full` | `write_opcua_nodes` · `call_opcua_method` |

Control and alarm tools also need a verified server (a secured channel and a pinned `OPCUA_SERVER_CERT` or an `OPCUA_SERVER_TRUST_STORE`) unless a lab override is set. † Works only on a server that advertises the feature it needs, such as historical access.

<!-- END GENERATED: tool-summary -->

## Safety and production

> [!WARNING]
> By default the agent can only read, but the OPC UA connection is
> **unencrypted and anonymous**. That's fine for a simulator or a lab, not for
> real equipment. Secure the connection before connecting to anything that matters.

**1. Secure the connection and pin the server.** Add these to your agent's
`env` block, with paths to your own certificate files
([certificate guide](docs/certificates.md)):

```text
OPCUA_SECURITY_POLICY=Basic256Sha256     # implies SignAndEncrypt
OPCUA_CLIENT_CERT=/etc/opcua/client.pem  # this client's identity
OPCUA_CLIENT_KEY=/etc/opcua/client_key.pem
OPCUA_SERVER_CERT=/etc/opcua/server.pem  # pin the server you meant to reach
```

<details>
<summary>Logging in as a user, or trusting a CA instead of pinning</summary>

For a username and password, set both `OPCUA_USERNAME` and `OPCUA_PASSWORD`.
Supply the password through your client's secret storage or environment; the
installer never accepts it as a flag ([password handling](docs/install.md#passwords)).

For an X.509 user identity, leave the username and password unset and set both
`OPCUA_USER_CERT` and `OPCUA_USER_KEY`. These identify the user and are separate
from `OPCUA_CLIENT_CERT` and `OPCUA_CLIENT_KEY`, which secure the channel; X.509
user authentication needs a security policy other than `None`.

To trust a CA instead of pinning one certificate, set `OPCUA_SERVER_TRUST_STORE`
with `OPCUA_SERVER_APPLICATION_URI` ([certificate guide](docs/certificates.md)).

</details>

**2. Choose what the agent may do** with `OPCUA_PROFILE`:

| Profile | What the agent can do |
|---|---|
| `observe` *(default)* | Read, browse, history, subscriptions, events. No writes, no method calls. |
| `operator` | The above, plus **only** the nodes and methods you allowlist in `OPCUA_ALLOWED_WRITE_NODES` / `OPCUA_ALLOWED_METHODS`, optionally with value limits from a policy file. |
| `full` | Every tool. Only for a tightly scoped OPC UA account. |

**3. Keep a record.** Set `OPCUA_AUDIT_FILE` for an append-only log of every
control call: what was asked, whether it was allowed, and what happened.

A wrong setting stops the server at startup with a message naming the variable,
rather than failing later against live equipment. This policy adds to OPC UA's
own permissions; it doesn't replace them, so scope the OPC UA account to the
same nodes and methods. All settings, value limits and policy files:
[configuration](docs/configuration.md). Threat model: [SECURITY.md](SECURITY.md).

## Documentation

| Guide | What's inside |
|---|---|
| [Install](docs/install.md) | The `.mcpb` bundle, single-file executables, choosing a runtime, troubleshooting |
| [Configuration](docs/configuration.md) | Every setting, profiles, allowlists, value bounds, secure connections, reconnection |
| [Tools](docs/tools.md) | Full tool reference, result shapes, request limits, partial results |
| [Examples](docs/examples.md) | Every tool with real calls and responses against the mock plant |
| [Security](SECURITY.md) | What is and is not verified, the audit trail, reporting a vulnerability |
| [Certificates](docs/certificates.md) | Generating a client certificate a server will accept |
| [Compatibility](docs/compatibility.md) | Servers tested, and where the Python and Node runtimes differ |
| [Architecture](docs/architecture.md) | How it fits together, and why |
| [Testing](docs/testing.md) | The test suite, MCP Inspector and agent walkthroughs |
| [Roadmap](ROADMAP.md) · [Changelog](CHANGELOG.md) | What is next, and what has landed |

## Contributing

Contributions are welcome — see **[CONTRIBUTING.md](CONTRIBUTING.md)** for the
project layout, local development and adding a tool to both runtimes.

New here? The [good first issues](https://github.com/IndustriAgents/OPCUA-MCP/issues?q=is%3Aissue%20is%3Aopen%20label%3A%22good%20first%20issue%22)
are small and scoped to one pull request: a setup guide for another MCP client,
or a sample application built on the simulated plant. None needs OPC UA hardware.

The most useful thing you can send is a result from a real OPC UA server: open a
[compatibility report](https://github.com/IndustriAgents/OPCUA-MCP/issues/new?template=compatibility_report.md)
saying which server, which version and which tools worked. Test only on equipment
you are authorised to use, and keep writes and method calls to a simulator or lab.

## License

MIT — see [LICENSE](LICENSE).

Tool inputs and structured results use JSON Schema draft 2020-12 with generated
TypeScript/Python types and CI drift checks. See
[contract generation](docs/contract-generation.md) for the authoring workflow.

TDQS

A4.3/5.0

Scored across 11 tools

Disambiguation4/5

Most tools target clearly different operations: browsing vs current reads vs history vs live data-change subscriptions vs live events vs alarm listing. The closest pairs are read_events/read_event_history and subscribe_events/subscribe_opcua_nodes, whose names are similar but whose descriptions clearly separate live buffering from archived retrieval and event streams from data-change streams. Slight ambiguity remains from those parallel names, but the descriptions prevent likely misselection.

Naming Consistency4/5

All names follow a snake_case verb_noun pattern, which is readable and predictable. The main inconsistency is the optional 'opcua' qualifier: read_opcua_nodes, browse_opcua_nodes, read_opcua_history, subscribe_opcua_nodes, and unsubscribe_opcua_nodes use it, while read_event_history, subscribe_events, read_events, list_subscriptions, and list_active_alarms do not. This is a minor deviation rather than a chaotic naming scheme.

Tool Count5/5

At 11 tools, the set is well within a reasonable range for an OPC UA monitoring and browsing server. Each tool covers a distinct capability: status, browse, current read, historical read, data-change subscription lifecycle, event subscription/read, event history, active alarms, and subscription listing. No tool appears redundant or purely filler.

Completeness3/5

The read/monitoring surface is fairly complete: browse, current values, historical values, live data changes, event buffering, event history, alarms, and server capability discovery are all present. However, core OPC UA write operations such as writing node values or calling methods are absent, and alarm acknowledgement is not exposed even though alarm listing is. There is also a reference to an 'act_on_alarm' tool in the browse description that is not present in the tool set, indicating a notable surface gap.

Maintenance

ActivityActive
ResponsivenessLimited data