open289-mcp
Server Configuration
Describes the environment variables required to run the server.
| Name | Required | Description | Default |
|---|---|---|---|
| OPEN289_SIM | No | Set to 1 to use the virtual IR3000 FC + Fluke 289 instead of Bluetooth hardware. | |
| OPEN289_HOME | No | Directory used for open289 state/ and data/ folders. Defaults to the source checkout if present, otherwise %LOCALAPPDATA%\open289 on Windows or ~/.local/share/open289 elsewhere. | |
| OPEN289_NO_BLE | No | Set to 1 to make the real Bluetooth backend refuse to start, preventing hardware access. | |
| OPEN289_SIM_RATE | No | Virtual meter live notifications per second. | 4 |
| OPEN289_SIM_AUDIT | No | Override path for the virtual meter GATT write audit file. | |
| OPEN289_SIM_DELAY | No | Virtual meter pass-through send latency in seconds. | 0.05 |
| OPEN289_SIM_STATE | No | Override path for the virtual meter state file. |
Instructions
Guidance the server publishes about itself, which clients place ahead of the tool catalog so the model reads it before choosing anything.
Read a Fluke 287/289 multimeter through a Fluke IR3000 FC Bluetooth adapter clipped onto its IR port.
Start with status (adapter and meter identity, batteries, saved items). read returns what the display shows now
(function, range, modes such as HOLD or MIN MAX, the primary value and every other reading); live collects real-time
readings (about 4/s) and returns their statistics and the last few; for minutes or hours use log_start, then
log_status and log_stop (a CSV/JSONL file written in the background). memory lists saved measurements, MIN MAX
and peak sessions and trend recordings; download_recording saves one recording to a file. press simulates
front-panel keys, query sends read-only remote commands (ID, IM, Q*), selftest checks adapter, link and meter.
Values are in SI base units (V, A, ohm, F, Hz, s), display is the text the meter shows.
The adapter accepts ONE connection: tools run one at a time, and while a background log runs every other meter tool
returns BUSY until log_stop (BUSY also when another program, such as Fluke Connect or another open289, holds the
adapter). METER_BUSY means the meter shows a page that blocks queries (a MIN MAX / Peak / recording result page or a
saved-item viewer): close it on the meter (or with press, usually F4) and retry. NOT_FOUND = the adapter is not advertising (press its button until the LED flashes green); DETACHED = no
powered meter on the adapter. Safety: press changes the meter's state (HOLD, MIN MAX, range ...); ONOFF needs
allow_off=true and switches the meter off for good (it cannot be switched on remotely, and the adapter sleeps too).
Menus and the "Leads connected incorrectly" warning do not show in any reading: when press reports a soft key that
changed nothing, or LEAD_ALERT_POSSIBLE, ask the user what the screen shows before pressing on. In current functions
a near-zero reading can also mean the leads are in the wrong jacks (the warning page reads as ~0 A, state NORMAL).
query is read-only: anything that could change or erase meter state is refused.
Capabilities
Features and capabilities supported by this server
Protocol revision2025-11-25
| Capability | Details |
|---|---|
| tools | {
"listChanged": false
} |
Tools
Functions exposed to the LLM to take actions
| Name | Description |
|---|---|
| statusA | Is the IR3000 FC adapter reachable and a Fluke 287/289 attached and on? Adapter address, firmware and battery %; meter model, firmware, serial, battery, memory level and clock; the number of saved items. meter.attached false = the adapter is not on a powered meter. NOT_FOUND = the adapter is not advertising (press its button until the LED flashes green; close Fluke Connect on any phone). |
| readA | One snapshot of the meter display: function (V_DC, OHMS ...), secondary function, range and autorange, modes (HOLD, MIN_MAX_AVG, REL, RECORD ...), the primary reading and every other reading on screen (MINIMUM, MAXIMUM, AVERAGE, SECONDARY, REL_REFERENCE ...). value is in SI base units, display is the text the meter shows. METER_BUSY = a result page or saved-item viewer is open. |
| liveA | Collect real-time readings from the adapter (about 4 per second) for |
| memoryA | What is saved in the meter's memory: the counts and every saved measurement, MIN MAX session, peak session and trend recording (name, time, function, primary value and the other readings; recordings also interval, number of records and duration). download_recording fetches the records of a recording; the index is the item's index within its kind. |
| download_recordingA | Download trend recording |
| pressA | Simulate front-panel keys in order (soft keys F1-F4 under the display, the arrows, HOLD, MINMAX, RANGE, INFO, BACKLIGHT, ONOFF) and return the display state after each key, which state fields changed ("changed": [] = nothing visible, ["view"] = a result page or viewer opened or closed, null = cannot tell; autorange range moves are not counted) and a "note" when the effect is invisible or absent. Menus, panels, help pages and the lead-alert warning overlay the reading and are invisible here, and a refused menu choice silently leaves the menu open: after a soft key that changed nothing, ask the user what the screen shows before the next soft key (a blind F4 can open Setup). "warnings": KEY_IGNORED, LEAD_ALERT_POSSIBLE (current function, leads in the wrong jacks), MENU_STATE_UNKNOWN. Key map per dial position: https://github.com/FrostFlops/open289/blob/main/docs/UI.md. held: a long press (RANGE held = back to autorange). ONOFF switches the meter OFF for good (it cannot be switched on remotely, and the adapter goes to sleep with it): it is refused unless allow_off is true; the meter then asks for confirmation (F1 confirms, F4 cancels). |
| queryA | Send read-only remote commands to the meter and return each answer (text, or hex for binary replies): ID (model, firmware, serial), IM, and Q* queries such as QM (primary measurement), QDDB (display data), QBL (battery), QSLS (saved counts), QMP . Anything else (PRESS, MP, CSD, RI, OFF ...) is refused with UNSAFE_OPERATION before it reaches the meter. |
| selftestA | Read-only health check of adapter, link and meter: adapter advertising, connection, meter attached, adapter firmware, ID, display snapshot, a live reading within 5 s, adapter and meter battery. Never changes the meter. SELFTEST_FAILED lists the failed checks (measured vs expected). |
| log_startA | Start logging live readings to a CSV or JSONL file in the background and return the job id and the file. The log ends after |
| log_statusA | State of a background log (running / done / failed), the records written so far, the last status line, the file, and once it has ended its summary (min/max/mean per unit, link gaps). |
| log_stopA | Stop the background log cleanly and return its summary: file, records, duration, min/max/mean per unit, link gaps. Without |
Prompts
Interactive templates invoked by user choice
| Name | Description |
|---|---|
No prompts | |
Resources
Contextual data attached and managed by the client
| Name | Description |
|---|---|
No resources | |
TDQS
Scored across 11 tools
Most tools have clearly distinct purposes (press, read, live, log_start/status/stop, download_recording, memory), but a few pairs overlap: `read` (single snapshot), `live` (short burst) and `query` with QM/QDDB all surface measurement data, and `status` vs `selftest` both report adapter/link/meter health. The detailed descriptions make the intended boundaries workable, so confusion is limited to one or two edges.
The log lifecycle follows a clean prefix pattern (log_start, log_status, log_stop) and download_recording is verb_noun, but the rest mixes bare verbs (read, press, query, live), a noun (memory, status) and a compound (selftest). The names are readable and mostly self-explanatory, but there is no single predictable convention across the set.
Eleven tools sit in the well-scoped range, and each maps to a distinct capability: snapshot reading, live sampling, background logging lifecycle, recording download, memory listing, key simulation, safe raw queries, self-test and connection status. No tool feels redundant or like filler.
The surface covers the full read/log/download lifecycle plus device health and key-driven UI control, which matches the remote-metering domain well. Minor gaps remain: no tool to erase or manage saved memory items, no way to set the meter clock or configuration beyond simulated key presses, and no explicit cancel/resume for in-progress downloads beyond the documented start/out parameters.