[ { "id": "nec-210-52-a", "code_ref": "NEC 210.52(A)(1)", "title": "Receptacle Outlets - Dwelling Unit Spacing", "category": "electrical", "jurisdiction": "National", "summary": "Receptacles shall be installed such that no point along the floor line of any wall space is more than 6 feet from a receptacle outlet. Receptacles shall be no more than 12 feet apart.", "source": "NEC 2023 Section 210.52(A)(1)", "common_questions": [ "How far apart should outlets be?", "What is the maximum spacing for electrical outlets?", "How many outlets do I need in a room?" ], "notes": "Wall space includes any space 2 feet or more in width. Doorways, fireplaces, and similar openings do not break wall space.", "related_codes": ["NEC 210.52(A)(2)", "NEC 210.52(A)(3)"] }, { "id": "nec-210-52-c", "code_ref": "NEC 210.52(C)(1)", "title": "Kitchen Countertop Receptacles", "category": "electrical", "jurisdiction": "National", "summary": "Receptacle outlets shall be installed at kitchen countertops so that no point along the wall line is more than 24 inches from a receptacle outlet.", "source": "NEC 2023 Section 210.52(C)(1)", "common_questions": [ "How far apart should kitchen outlets be?", "Do I need outlets above kitchen counters?", "Kitchen outlet spacing requirements" ], "notes": "Receptacles shall be located above, but not more than 20 inches above, the countertop.", "related_codes": ["NEC 210.52(C)(2)", "NEC 210.8(A)(6)"] }, { "id": "nec-210-8-a-1", "code_ref": "NEC 210.8(A)(1)", "title": "GFCI Protection - Bathrooms", "category": "electrical", "jurisdiction": "National", "summary": "All 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms shall have ground-fault circuit-interrupter (GFCI) protection.", "source": "NEC 2023 Section 210.8(A)(1)", "common_questions": [ "Do I need GFCI in bathroom?", "What outlets require GFCI protection?", "Is GFCI required for bathroom outlets?" ], "notes": "This includes all receptacles, not just those near water sources.", "related_codes": ["NEC 210.8(A)(6)", "NEC 210.8(A)(7)"] }, { "id": "irc-r311-7-5-1", "code_ref": "IRC R311.7.5.1", "title": "Stair Riser Height", "category": "structural", "jurisdiction": "National", "summary": "The maximum riser height shall be 7-3/4 inches. The riser shall be measured vertically between leading edges of the adjacent treads.", "source": "IRC 2021 Section R311.7.5.1", "common_questions": [ "How tall can stair risers be?", "Maximum stair riser height?", "What is code for stair height?" ], "notes": "The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch.", "related_codes": ["IRC R311.7.5.2", "IRC R311.7.5.3"] }, { "id": "irc-r311-7-5-2", "code_ref": "IRC R311.7.5.2", "title": "Stair Tread Depth", "category": "structural", "jurisdiction": "National", "summary": "The minimum tread depth shall be 10 inches. The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads.", "source": "IRC 2021 Section R311.7.5.2", "common_questions": [ "How deep should stair treads be?", "Minimum stair tread depth?", "What is code for stair tread?" ], "notes": "The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch.", "related_codes": ["IRC R311.7.5.1", "IRC R311.7.6"] }, { "id": "ipc-709-1", "code_ref": "IPC 709.1", "title": "Kitchen Sink Drain Size", "category": "plumbing", "jurisdiction": "National", "summary": "Kitchen sinks shall have a minimum 1-1/2 inch diameter drain pipe.", "source": "IPC 2021 Section 709.1", "common_questions": [ "What size drain pipe for kitchen sink?", "Kitchen sink drain size requirements?", "Minimum pipe size for kitchen drain?" ], "notes": "Garbage disposals typically require the same minimum size.", "related_codes": ["IPC 709.2", "IPC 709.3"] } ]

Latest Blog Posts

MCP directory API

We provide all the information about MCP servers via our MCP API.

curl -X GET 'https://glama.ai/api/mcp/v1/servers/jrszilard/diy-helper-mcp-servers'

If you have feedback or need assistance with the MCP directory API, please join our Discord server