# fortune-impedance — Ground Truth Review
Paper: fortune-impedance
Item key: VP3NJ74M
Total tables: 7 (1 artifact + 6 data)
---
## table_0 (p1) — ARTIFACT: unknown [0 cols × 0 rows]
- **Caption:** b Department of Electrical and Computer Engineering, University of Canterbury, Christchurch, New Zealand
- **Notes:** Artifact: article_info_box, not a data table
- **Verified:** false
(No table to render — headers and rows are empty.)
---
## table_1 (p3) — Table 1 Component values used for the three control DUT data sets. [7 cols × 3 rows]
- **Caption:** Table 1 Component values used for the three control DUT data sets.
- **Notes:** Two-level column headers: ZTA spans R_1(Ω), R_2(kΩ), C_1(nF); ZTB spans R_4(Ω), R_3(kΩ), C_2(nF).
- **Verified:** false
| Data set | R_1 (Ω) | R_2 (kΩ) | C_1 (nF) | R_4 (Ω) | R_3 (kΩ) | C_2 (nF) |
|---|---|---|---|---|---|---|
| 1 | 998.2 | 333.5 | 3.4 | 998.8 | 219.5 | 0.96 |
| 2 | 998.2 | 46.9 | 1029.0 | 998.8 | 47.2 | 1000 |
| 3 | 998.2 | 333.5 | 1.2 | 998.8 | 219.5 | 1.1 |
---
## table_2 (p5) — Table 2 Error between the custom impedance analyser (CIA) and the theoretical im... [5 cols × 4 rows]
- **Caption:** Table 2 Error between the custom impedance analyser (CIA) and the theoretical impedance of the control DUT over the range of 1 Hz–100 kHz (magnitude) and 1 Hz–10 kHz (phase), quantified by the root-mean-square error normalised using the mean of the theoretical impedance of the control DUT.
- **Notes:** Two-level column headers: ZA spans |Z|(%) and φ(%); ZB spans |Z|(%) and φ(%). Lowest-level headers used.
- **Verified:** false
| Data set | \|Z\| (%) | φ (%) | \|Z\| (%) | φ (%) |
|---|---|---|---|---|
| 1 | 4.7 | 2.7 | 5.7 | 5.3 |
| 2 | 5.3 | 1.6 | 5.6 | 1.5 |
| 3 | 3.8 | 3.4 | 4.6 | 4.2 |
| Mean (SD) | 4.6 (0.7) | 2.6 (0.9) | 5.3 (0.6) | 3.6 (2.0) |
---
## table_3 (p5) — Table 3 Error between the custom impedance analyser (CIA) and the Keysight imped... [5 cols × 11 rows]
- **Caption:** Table 3 Error between the custom impedance analyser (CIA) and the Keysight impedance analyser (KIA) measured combined impedance of electrodes A and B on human subjects over the range of 1 Hz–100 kHz (magnitude) and 1 Hz–9.4 kHz (phase), quantified by the root-mean-square error normalised using the mean of the KIA.
- **Notes:** Two-level column headers: Ag/AgClNSP spans |Z|(%) and φ(%); Ag/AgClSP spans |Z|(%) and φ(%). Lowest-level headers used.
- **Verified:** false
| Subject | \|Z\| (%) | φ (%) | \|Z\| (%) | φ (%) |
|---|---|---|---|---|
| 1 | 3.3 | 0.9 | 1.7 | 14.9 |
| 2 | 7.6 | 3.7 | 6.4 | 11.3 |
| 3 | 14.4 | 2.7 | 3.4 | 4.4 |
| 4 | 1.8 | 0.8 | 1.2 | 24.0 |
| 5 | 16.9 | 1.7 | 1.6 | 19.0 |
| 6 | 9.4 | 0.6 | 3.2 | 4.2 |
| 7 | 4.4 | 1.3 | 17.4 | 5.5 |
| 8 | 64.8 | 12.8 | 11.3 | 9.8 |
| 9 | 1.5 | 0.9 | 8.6 | 4.2 |
| 10 | 0.8 | 1.1 | 2.6 | 8.9 |
| Mean (SD) | 12.5 (19.2) | 2.7 (3.7) | 5.7 (5.3) | 10.6 (6.8) |
---
## table_4 (p6) — Table 4 Electrode–skin impedance imbalance quantified using a root mean square e... [7 cols × 36 rows]
- **Caption:** Table 4 Electrode–skin impedance imbalance quantified using a root mean square error between ZA and ZB for ten healthy subjects over three different frequency ranges: 50 Hz, 1 Hz–492.4 Hz and the entire range, 1 Hz–100 kHz (magnitude) and 1 Hz–9.4 kHz (phase).
- **Notes:** Three electrode configuration sub-sections each introduced by a sub-header row spanning all columns: Ag/AgClNSP, Ag/AgClSP, Ag-SP. Two-level column headers: 50 Hz, Bio-signal range, and Whole range each span |Z|(kΩ) and φ(deg). Lowest-level headers used. All three sections have 10 data rows (subjects 1-10) plus a Mean (SD) row.
- **Verified:** false
| Subject | \|Z\| (kΩ) | φ (deg) | \|Z\| (kΩ) | φ (deg) | \|Z\| (kΩ) | φ (deg) |
|---|---|---|---|---|---|---|
| Ag/AgClNSP | | | | | | |
| 1 | 20.6 | 16.2 | 473.0 | 30.1 | 350.8 | 25.1 |
| 2 | 9.2 | 4.7 | 9.8 | 3.8 | 7.3 | 3.4 |
| 3 | 12.5 | 6.7 | 13.8 | 4.7 | 10.3 | 4.0 |
| 4 | 2.8 | 12.4 | 1447.0 | 14.8 | 1073.1 | 12.3 |
| 5 | 120.5 | 14.8 | 142.8 | 16.2 | 106.0 | 13.6 |
| 6 | 116.9 | 10.1 | 264.3 | 12.4 | 196.1 | 10.4 |
| 7 | 21.6 | 10.0 | 298.9 | 7.8 | 221.7 | 6.6 |
| 8 | 2.1 | 6.4 | 32.6 | 6.6 | 24.2 | 5.6 |
| 9 | 0.9 | 2.7 | 82.4 | 4.1 | 61.1 | 3.4 |
| 10 | 69.2 | 65.5 | 607.1 | 56.3 | 450.3 | 47.7 |
| Mean (SD) | 37.6 (47.1) | 15.0 (18.3) | 337.2 (439.3) | 15.7 (16.4) | 250.1 (325.8) | 13.2 (13.8) |
| Ag/AgClSP | | | | | | |
| 1 | 0.3 | 0.0 | 0.3 | 1.1 | 0.2 | 3.2 |
| 2 | 1.4 | 1.1 | 1.4 | 3.8 | 1.1 | 10.9 |
| 3 | 8.3 | 6.6 | 8.3 | 11.5 | 6.3 | 23.2 |
| 4 | 0.1 | 0.7 | 0.1 | 0.6 | 0.0 | 1.5 |
| 5 | 0.2 | 0.0 | 0.2 | 0.7 | 0.2 | 1.6 |
| 6 | 1.8 | 2.0 | 1.9 | 3.3 | 1.4 | 6.5 |
| 7 | 24.6 | 22.2 | 29.4 | 21.6 | 21.8 | 21.9 |
| 8 | 1.3 | 4.0 | 1.3 | 6.7 | 1.0 | 14.1 |
| 9 | 7.0 | 9.2 | 6.9 | 15.1 | 5.1 | 22.2 |
| 10 | 0.3 | 0.5 | 0.3 | 1.2 | 0.3 | 4.8 |
| Mean (SD) | 4.5 (7.7) | 4.6 (6.9) | 5.0 (9.0) | 6.6 (7.2) | 3.8 (6.7) | 11.0 (8.8) |
| Ag-SP | | | | | | |
| 1 | 7.8 | 1.5 | 12.5 | 2.0 | 9.3 | 4.5 |
| 2 | 37.4 | 1.5 | 39.4 | 6.5 | 29.4 | 7.4 |
| 3 | 63.8 | 1.3 | 113.1 | 7.2 | 83.9 | 7.6 |
| 4 | 7.4 | 2.8 | 16.1 | 2.8 | 12.0 | 2.6 |
| 5 | 0.8 | 0.4 | 0.8 | 0.8 | 0.6 | 1.8 |
| 6 | 14.9 | 1.0 | 39.0 | 2.6 | 28.9 | 3.8 |
| 7 | 143.2 | 10.4 | 245.2 | 10.4 | 181.9 | 9.3 |
| 8 | 0.8 | 3.0 | 13.6 | 4.9 | 10.1 | 4.1 |
| 9 | 69.3 | 9.8 | 529.6 | 6.2 | 39.3 | 5.2 |
| 10 | 16.6 | 2.2 | 26.4 | 3.2 | 19.6 | 4.4 |
| Mean (SD) | 36.2 (45.1) | 3.4 (3.6) | 103.6 (166.8) | 4.7 (2.9) | 76.9 (123.7) | 5.1 (2.3) |
---
## table_5 (p6) — Table 5 Mean electrode–skin impedance imbalance and imbalance reduction after ap... [5 cols × 3 rows]
- **Caption:** Table 5 Mean electrode–skin impedance imbalance and imbalance reduction after applying the compensation network, quantified using a root mean square error between Z_A and Z_B over 1 Hz–9.4 kHz.
- **Notes:** Two-level column headers: Absolute imbalance spans |Z|(kΩ) and φ(deg); Imbalance reduction spans |Z|(kΩ) and φ(deg). Lowest-level headers used.
- **Verified:** false
| Electrode configuration | \|Z\| (kΩ) | φ (deg) | \|Z\| (kΩ) | φ (deg) |
|---|---|---|---|---|
| Ag/AgClNSP | 25.0 ± 29.0 | 3.8 ± 2.1 | 284.3 ± 361.8 | 11.9 ± 15.8 |
| Ag/AgClSP | 0.4 ± 1.0 | 0.3 ± 0.6 | 4.6 ± 8.1 | 6.2 ± 6.7 |
| Ag-SP | 12.9 ± 15.4 | 2.2 ± 1.4 | 86.7 ± 143.1 | 2.5 ± 2.3 |
---
## table_6 (p6) — Table 6 [5 cols × 3 rows]
- **Caption:** Table 6
- **Notes:** Full caption: Table 6 Mean and standard deviation of the compensation network component values.
- **Verified:** false
| Electrode configuration | R'_A (kΩ) | C'_A (nF) | R'_B (kΩ) | C'_B (nF) |
|---|---|---|---|---|
| Ag/AgClNSP | 1884 ± 3158 | 144.8 ± 237.2 | 1748 ± 1886 | 141.8 ± 207.4 |
| Ag/AgClSP | 99.6 ± 115.2 | 6.6 ± 9.9 | 102.9 ± 118.6 | 6.8 ± 10.4 |
| Ag-SP | 2811 ± 3736 | 202.2 ± 403.7 | 2816 ± 3465 | 487.9 ± 1153 |
---
## Review Checklist
- [ ] table_0 — artifact confirmed
- [ ] table_1 — 3 rows, 7 cols verified
- [ ] table_2 — 4 rows, 5 cols verified
- [ ] table_3 — 11 rows, 5 cols verified
- [ ] table_4 — 36 rows, 7 cols verified
- [ ] table_5 — 3 rows, 5 cols verified
- [ ] table_6 — 3 rows, 5 cols verified