Skip to main content
Glama

LexGrid EU MDR Medical Devices & Pharma Serialization MCP

Server Details

Medical device risk classification engine under MDR (Reg. 2017/745) Annex VIII 22 rules, EUDAMED Basic UDI-DI & GS1 GTIN-14 Modulo 10 checksum validator, Article 87 statutory vigilance incident reporting timeline calculator (2, 10, 15 days), and Falsified Medicines Directive (FMD 2011/62/EU) 2D DataMatrix serialization auditor.

Ownership verified
Status
Healthy
Uptime
100.0% over the last 24 hours
Last Tested
Transport
Streamable HTTP · MCP 2025-11-25
URL
ChatGPT
–
Claude
–

TDQS

A3.8/5.0

Scored across 5 tools

Disambiguation5/5

Each tool targets a clearly distinct regulatory workflow: UDI-DI validation, FMD serialization auditing, clinical evaluation screening, risk classification, and vigilance deadline calculation. There is no plausible overlap in inputs or purpose between any pair, so an agent can select unambiguously.

Naming Consistency4/5

All names use snake_case with a domain prefix plus descriptive noun phrase (eudamed_, fmd_, mdr_), which is predictable and readable. The pattern is noun-centric rather than verb_noun and the prefixes vary by regulation, but conventions are not mixed within the set.

Tool Count4/5

Five tools is a well-scoped, each-earns-its-place set with no filler. It is slightly thin for a server framed as broad EU MDR plus pharma serialization coverage, but nothing is redundant.

Completeness3/5

Core workflows (classification, clinical evaluation, vigilance, UDI, serialization) are covered, but the MDR lifecycle has notable gaps: no post-market surveillance/PSUR or PMCF reporting tool, no technical documentation / Annex II gap assessment, and no declaration of conformity or EUDAMED actor/operator registration. These are likely agent dead ends for a full compliance workflow.

Publisher details

Operator
NovaPixel · Publisher source
Operator website
Not provided
Vendor relationship
Not provided
Documentation
Not provided
Privacy policy
Not provided
Trust center
Not provided
Restrictions
Not provided

Available Tools

5 tools
eudamed_udi_di_validatorEUDAMED Basic UDI-DI & UDI-DI / PI GS1 Modulo-10 Barcode ValidatorA
Read-onlyIdempotent
Inspect

[EUDAMED Basic UDI-DI & UDI-DI / PI GS1 modulo-10 barcode validator. Pure calculation, read-only, side-effect free]. Audits Basic UDI-DI and UDI-DI / UDI-PI structures under Regulation (EU) 2017/745 Article 27 and Implementing Regulation (EU) 2021/1239, verifying GS1 GTIN-14 modulo-10 check digits and production identifiers. Usage: Pass agency, Basic UDI-DI, and UDI-DI/PI strings to audit EUDAMED registration readiness and format human-readable text. Returns: JSON object with { issuingAgency: string, basicUdiDi: string, isBasicUdiDiValid: boolean, udiDi: string, isUdiDiValid: boolean, udiDiCheckDigitCalculated: number, udiPiElementsPresent: array, eudamedRegistrationReady: boolean, statutoryVerdict: string, formattedHumanReadableRepresentation: string }.

Inputs: udiDi (required), basicUdiDi (required), issuingAgency (required), udiPiLotNumber, +3 more.

fmd_pharma_serialization_matrix_auditorFalsified Medicines Directive (FMD) 2D DataMatrix Serialization AuditorA
Read-onlyIdempotent
Inspect

[Falsified Medicines Directive (FMD) 2D DataMatrix serialization auditor. Pure calculation & parsing, read-only, side-effect free]. Audits medicinal product safety features under Directive 2011/62/EU and Delegated Regulation (EU) 2016/161, validating GTIN-14 check digits, randomized serial numbers (<1:10,000 entropy), expiration dates, and anti-tampering seals. Usage: Pass pharmaceutical packaging identifiers to verify compliance with EMVS European Hub serialization standards. Returns: JSON object with { medicinalProductName: string, isSerializationCompliant: boolean, gtinCheck: object, serialNumberCheck: object, expirationDateCheck: object, antiTamperingDeviceAudit: object, emvsPayloadRepresentation: object, deficiencies: array }.

Inputs: serialNumber (required), batchOrLotNumber (required), gtinOrNtin14Digits (required), expirationDateYymmdd (required), +5 more.

mdr_clinical_evaluation_screenerMDR Article 61 Clinical Evaluation Report (CER) & Equivalence ScreenerA
Read-onlyIdempotent
Inspect

[MDR Article 61 clinical evaluation report (CER) & equivalence screener. Statutory audit, read-only, side-effect free]. Evaluates clinical evaluation sufficiency under Regulation (EU) 2017/745 Article 61 and Annex XIV, scoring literature search protocols, benefit-risk ratios, PMCF plans, and auditing Article 61(5) competitor access contracts. Usage: Pass clinical evaluation attributes and equivalence claims to audit sufficiency score before Notified Body submission. Returns: JSON object with { deviceName: string, overallSufficiencyScorePercent: number, statutoryVerdict: string, equivalenceAudit: object, literatureProtocolAudit: object, clinicalDataSufficiencyAudit: object, pmcfAudit: object, gapFindings: array, mandatoryNotifiedBodySubmissionItems: array }.

Inputs: deviceName (required), deviceRiskClass (required), isImplantableDevice (required), benefitRiskRatioAcceptable (required), +8 more.

mdr_device_classification_engineEU MDR Annex VIII Medical Device 22 Classification Rules EngineA
Read-onlyIdempotent
Inspect

[EU MDR Annex VIII medical device 22 classification rules engine. Pure statutory logic, read-only, side-effect free]. Determines medical device risk class (Class I, Is, Im, Ir, IIa, IIb, III) under Regulation (EU) 2017/745 Annex VIII based on invasiveness, duration, active functions, and anatomical site, specifying Notified Body conformity assessment routes. Usage: Pass device characteristics and intended purpose to obtain statutory classification, applicable Annexes, and PMS requirements. Returns: JSON object with { deviceName: string, riskClass: string, governingRule: string, notifiedBodyInterventionMandatory: boolean, conformityAssessmentRoutes: array, postMarketSurveillanceRequirement: string, summaryRationale: string }.

Inputs: deviceName (required), invasiveness (required), durationOfUse (required), isActiveDevice (required), +9 more.

mdr_vigilance_reporting_timeline_calculatorEU MDR Article 87 Vigilance Incident Reporting Statutory Deadlines CalculatorA
Read-onlyIdempotent
Inspect

[EU MDR Article 87 vigilance incident reporting statutory deadlines calculator. Pure calculation, read-only, side-effect free]. Calculates strict statutory notification deadlines under Regulation (EU) 2017/745 Article 87 (public health threat: 2 days; death/deterioration: 10 days; serious incidents: 15 days) and prepares initial MIR vigilance report payloads. Usage: Pass incident awareness date and severity classification to compute exact deadline dates and EUDAMED notification requirements. Returns: JSON object with { incidentReferenceId: string, incidentSeverityType: string, statutoryDeadlineDays: number, dateOfIncidentAwarenessIso: string, statutoryDeadlineDateIso: string, isImmediateNotificationMandatory: boolean, eudamedReportingFormType: string, initialReportRequiredContent: object }.

Inputs: deviceName (required), manufacturerName (required), incidentReferenceId (required), incidentSeverityType (required), +4 more.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    Related MCP Servers

    • A
      license
      Not graded
      quality
      C
      maintenance
      Remote MCP server that lets AI assistants read tracked competitive intelligence — competitor news, reviews, website changes, social posts and ads — and act on it by managing projects, competitors, battle cards, reports and canvases. Every answer carries a source and a date, and write actions only publish when explicitly shared.
      MIT
    • A
      license
      A
      quality
      D
      maintenance
      Enables brand visibility monitoring across major AI platforms like ChatGPT, Claude, Gemini, and Perplexity. It allows users to track visibility scores, analyze competitor data, and receive actionable insights to improve AI-generated brand recommendations.
      16
      11 npm
      1
      MIT
    • A
      license
      Not graded
      quality
      C
      maintenance
      Browse IndustryLens's published competitive-intelligence reports and head-to-head competitor comparisons from any AI agent — real, source-backed data.
      MIT
    Try in Browser

    Glama MCP Gateway

    Add one secure layer between your agents and this server.

    Resources