Orinyx
Server Details
Test healthcare AI agents' medication claims against cited FDA label text. Not for clinical use.
- Status
- Healthy
- Uptime
- 100.0% over the last 24 hours
- OAuth
- Works in Glama
- Last Tested
- Transport
- Streamable HTTP · MCP 2025-11-25
- URL
- Repository
- lexthirteen-ai/orinyx-mcp
- GitHub Stars
- 8
- Server Listing
- Orinyx MCP Server
- ChatGPT
- –
- Claude
- –
TDQS
Scored across 16 tools
Tools cluster cleanly into verification (structured vs free-text), FDA label lookup/read, OTC monograph lookup/read, and exam sitting, with descriptions explicitly steering between similar pairs (e.g., get_next_exam_case vs get_exam_cases, verify_order_text vs verify_medications). Minor overlap remains: get_accuracy partly duplicates the accuracy data already returned by get_verification, which could cause occasional misselection.
Almost all names follow a clean verb_noun snake_case pattern (find_fda_label, read_fda_label_section, verify_order_text, get_exam_report, export_verification). The lone deviation is start_a_test, which inserts an article and breaks the verb_noun rhythm, but overall the convention is highly predictable.
Sixteen tools are slightly above the ideal 3-15 range but map well to four real sub-domains (verification, FDA labels, OTC monographs, exams). Each tool has a clear role, with no obviously gratuitous additions.
Core lifecycles are covered: claims can be verified (structured or free-text), saved runs read, exported, and scored; labels and monographs can be found and read section-by-section; exams can be started, answered, finished, and reported. Minor gaps exist, e.g., no tool to list all saved verification runs or enumerate prior exam sittings, forcing agents to already know IDs.
Publisher details
- Operator
- Orinyx LLC · Publisher source
- Operator website
- Unknown
- Vendor relationship
- First-party
- Documentation
- Unknown
- Trust center
- Unknown
- Restrictions
- Unknown
Available Tools
16 toolsexport_verificationBInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. Export a run as csv, pdf (full audit) or report (one-page committee PDF).
Inputs: run_id (required), fmt.
find_fda_labelAInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. Find the FDA prescribing label Orinyx holds for a drug name or RxCUI (a brand name only where Orinyx has a curated alias for it): the SPL set ID, label version, effective date and which sections carry text. Reference text only: not a verification and not a verdict. A name that is not found is reported as given; never respell it or try a guessed alternative.
Inputs: drug (required). Returns: result
find_otc_monographsCInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. Find FDA over-the-counter (OTC) drug monographs by exact ingredient name (for example 'acetaminophen'), exact category name, or words in the title. Reference text only: it is not a verification and not a verdict.
Inputs: category, ingredient, title_contains. Returns: result
finish_examCInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. Sitting an exam: close the sitting once every case is answered. It is then scored and no answer can be added.
Inputs: run_id (required), allow_partial. Returns: result
get_accuracyBInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. The physician-review accuracy tally for a run: false-flag rate and the catch-rate estimate with its sample size; nothing when no review exists.
Inputs: run_id (required). Returns: result
get_exam_casesBInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. Sitting an exam: get every case at once (transcripts, patient messages or encounter notes) and how to answer them. Speed is then reported as not measured; prefer get_next_exam_case.
Inputs: run_id (required). Returns: result
get_exam_reportBInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. The report of a finished exam: for a transcript exam the catch rate, false-flag rate and abstain rate; for a patient-message exam the handled rate, false alarms and unreadable replies; for an ICD-10-CM coding exam code recall, precision, invalid codes and exact cases; each with its denominator, the pass/advisory/fail result, and the product's speed per case. A pass is not a clinical safety clearance of the product. A result on an unsigned draft test set is marked REHEARSAL and is not evidence.
Inputs: run_id (required). Returns: result
get_next_exam_caseBInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. Sitting an exam: get the next unanswered case (a transcript or a patient message with patient context, or an encounter note with its date of service) and how to answer it: medication claims with the claim shapes the checker reads, the reply text, or ICD-10-CM diagnosis codes. Orinyx starts timing the case when it is first served.
Inputs: run_id (required). Returns: result
get_otc_monographCInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. What one FDA OTC monograph (id like M013) covers: ingredients, categories, its current documents and its orders.
Inputs: monograph_id (required). Returns: result
get_verificationCInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. Read a saved verification run (and its physician-review accuracy, if any). Each row names the check that produced it (beta).
Inputs: run_id (required). Returns: result
read_fda_label_sectionAInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. Read one section of a cached FDA prescribing label by its SPL set ID. section is
one of: contraindications, boxed_warning, warnings, warnings_and_cautions, overdosage,
dosage_and_administration, indications_and_usage, drug_interactions,
dosage_forms_and_strengths. A long section comes in parts; when the reply says
TRUNCATED, call again with the offset it gives before relying on the text. version
reads a superseded label version and the reply says so. When one set ID backs two
drugs the reply asks for rxcui: pass the one find_fda_label showed. Reference text,
not a verdict and not clinical advice.
Inputs: set_id (required), section (required), rxcui, offset, +1 more. Returns: result
read_otc_monograph_sectionAInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. Read FDA OTC monograph text. With only a document number: lists its sections. With a section reference (like M013.50): returns that section's text and where it came from. A long section comes in parts; when the reply says TRUNCATED, call again with the offset it gives before relying on the text. Reference text, not a verdict and not clinical advice.
Inputs: document_id (required), offset, section. Returns: result
start_a_testAInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. START HERE. Asks what kind of test you want (a quick check of medication claims, a scored exam of an AI product, or an FDA reference lookup) and gives the exact next step for the account that is signed in.
Inputs: no named parameters. Returns: result
submit_exam_answersAInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. FOR AN ORINYX EXAM ONLY: record your answers. answers is a list with exactly one
answer field each: {caseId, claims} for a transcript case, {caseId, replyText} for a
patient-message case (the reply exactly as the product would send it; an empty
string is recorded as unreadable), or {caseId, codes} for an encounter-note case
(ICD-10-CM diagnosis codes as strings like "E11.9", at most 25, no CPT or HCPCS; an
empty list is a valid answer; never send a date, the case has its date of service).
Claims are the medication claims exactly as the exam transcript
states them, including any that look wrong, each {rawText, drug, claimType,
structuredValue}. Claim types and their structuredValue keys are listed with each
case; a contraindication the clinician says does not apply is
{condition, asserted: false}. An empty claims list is a valid answer. This is how
the exam is scored, not documentation or clinical guidance: in real use a medication
statement that looks wrong is carried and raised with the clinician. Use only the
transcript's words, never real patient data. An answer cannot be changed once
recorded, and how Orinyx judged it is not shown until the report.
Inputs: run_id (required), answers (required). Returns: result
verify_medicationsAInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. Verify STRUCTURED medication claims. Each claim: {rawText, drug, claimType, structuredValue} where claimType is one of dose_range, route, frequency, indication, contraindication, interaction, monitoring, controlled_substance, rems_attestation. One claimType per claim: an order with a dose AND a route is two claims. Send one patient's medications per call: when the call states one route for a drug (in the structuredValue of its route, dose_range or frequency claims), that route is carried onto the drug's frequency claims that state none. Nothing is carried for a drug whose claims state two routes or one Orinyx cannot read, or whose drug name names a different route; a route written only in a drug name is never carried. For an order as written ("warfarin 5 mg by mouth daily") use verify_order_text instead. Returns what was checked, every flag with its severity, reason and citation. Each row names the check that produced it (beta). Claims must be synthetic test data, never real patient records or identifiers: rawText is stored in the audit record.
Inputs: claims (required), tool_name, tool_version, check_interactions. Returns: result
verify_order_textBInspect
Not for clinical use. Orinyx checks medication claims against cited FDA label text for testing and evaluation only. Do not use its results to diagnose, treat, prescribe or make patient care decisions. Use synthetic test data only. Verify medication orders exactly as written, e.g. "warfarin 5 mg by mouth daily" (one drug per order, at most 50 orders of 500 characters). Orinyx splits each order into its dose, route and frequency claims itself, with no model, and checks each on its own, so a part it cannot read never hides one it can. Pass the text unchanged: never correct, complete or re-spell an order first. Each row names the check that produced it (beta). Orders must be synthetic test data, never real patient records or identifiers: the text is stored in the audit record.
Inputs: orders (required), tool_name, tool_version, check_interactions. Returns: result
Tool Schema Changelog
Recent tool additions, removals, and schema changes observed during successful MCP inspections.
Loading tool schema changelog…
Related MCP Connectors
See how AI assistants talk about your pharmaceutical brands and which sources they cite.
Physician-reviewed medical opinions and prescriptions for AI agents.
Official FDA recalls, drug labels, adverse events and clinical trials, with cited sources.
Free health AI: drug interaction checks, medicine facts and health questions in 90+ languages
Related MCP Servers
- AlicenseAqualityBmaintenanceAnswers medication questions from official FDA labels with section citations, resolves drug names via RxNorm, and reports FDA recalls and shortages.41MIT
- AlicenseBqualityDmaintenanceEnables querying FDA drug label information including adverse reactions, warnings, and indications through natural language.517 npmGPL 3.0
- AlicenseAqualityDmaintenanceEnables querying FDA drug label information including adverse reactions, warnings, and indications via natural language.510 npm1GPL 3.0
- AlicenseNot gradedqualityCmaintenanceEnables AI assistants and MCP clients to query FDA drug labels, FAERS adverse-event reports, recalls, and label-documented drug interactions, returning structured, cited results.MIT
Glama MCP Gateway
Add one secure layer between your agents and this server.