check_scorpion_stem
A Scorpion probe's two melting temperatures, side by side: the stem-loop's own hairpin and the duplex the loop makes with its target on the amplicon.
Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| probe | Yes | the whole probe element, 5' stem arm + loop + 3' stem arm. The element is what folds, so it is what the structure engine is given - the loop alone would compute a hairpin the molecule does not have. | |
| _files | No | The project: record references shaped like _subject. Their records become library documents a tool names in sequences/parts/document; a trace or alignment is found by file name. | |
| margin | No | how many °C the stem Tm must exceed the loop-target Tm for the verdict to pass. Yours to set: the 5-10 °C rule of thumb this defaults to the floor of is a design tool's, not a measured value from the primary literature. In °C. | |
| target | Yes | the loop's target on the amplicon, 5'->3'. This is the OTHER temperature: a Scorpion opens because the loop finds this, so it is the loop-target duplex that has to be stable, not the loop's own self-structure. | |
| _subject | No | The record to act on: exactly one of sequence, accession (+source), sample (an id from list_samples) or file ({name, text} or {name, base64}); record_index picks one record of several. | |
| conditions | No | salt, magnesium, dNTP and oligo concentrations plus the salt-correction method the stem Tm is measured in. Left unset it is filled from your reaction-conditions settings, and falls back to primer3's defaults when there are none. Advanced. | |
| stem_length | No | how many bases of the 5' end form the stem arm. Reported back rather than guessed. The two vendors disagree on the range - LGC Biosearch, who sell Scorpions, publish 5-7 nt and PremierBiosoft's design tool says 6-7 - so neither is enforced. In nt. |
Output Schema
| Name | Required | Description | Default |
|---|---|---|---|
| notes | Yes | why a temperature is missing, in the words the panel shows. Empty when both were computed | |
| stemTm | Yes | melting temperature of the probe element's own hairpin, °C - null when no stem forms | |
| probeTm | Yes | melting temperature of the loop-target duplex, °C | |
| difference | Yes | stemTm - probeTm, the quantity the design rule is about | |
| clearsMargin | Yes | whether the difference clears the margin GIVEN - null when either temperature could not be computed | |
| marginSource | Yes | where the margin came from, carried with the verdict so an unsourced rule of thumb is never mistaken for a measurement | |
| stemGcPercent | Yes | GC of the 5' stem arm - both vendors ask for a GC-rich stem |