guard_and_railing_code_checker_ontario
Read-only
Whether a guard is required, its minimum height, opening limit, climbing rule and design loads under the Ontario Building Code Part 9 and Part 3 for a described situation.
Tool call template
This tool declares no required parameters. Add optional parameters from the input schema as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {},
"name": "guard_and_railing_code_checker_ontario"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| use | No | normal = ordinary guard; equip = access way to an equipment platform where many people are improbable. | normal |
| drop | No | Drop to the adjacent surface within 1.2 m (4 ft). A guard is required above 600 mm (23.6 in). | |
| unit | No | Unit of every length below. | mm |
| opening | No | Largest opening: the widest sphere that passes through the guard. | |
| location | No | dwelling = within a dwelling unit; exthouse = exterior serving one dwelling unit; part9 = other Part 9 building; exit3 = required exit in a larger (Part 3) building. | part9 |
| industrial | No | Industrial occupancy. | |
| loading_dock | No | Loading dock. | |
| planned_height | No | Guard height you plan. | |
| stair_triangle | No | Optional stair triangle gap, widest sphere. | |
| maintenance_only | No | Access for maintenance only. | |
| height_above_grade | No | Walking surface height above grade. |