check_qpcr_multiplex
Can these qPCR assays share a tube? Every unordered pair is scored on MultiPLX's five primer-primer and primer-product interactions and, beyond MultiPLX, on each assay's hydrolysis PROBE against the other assay's oligos (primer3 thal) — a probe consumed by a neighbour's primer loses signal while the PCR works perfectly, which reads as poor efficiency and is blamed on the primers.
Tool call template
Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {
"assays": "<assays>"
},
"name": "check_qpcr_multiplex"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| _files | No | The project: record references shaped like _subject. Their records become library documents a tool names in sequences/parts/document; a trace or alignment is found by file name. | |
| assays | Yes | the assays to pool: one object per assay with `name`, `forward`, `reverse`, `probe` and `amplicon`. Wire `design_qpcr_assay` outputs here, or list them yourself. Without `amplicon` the two primer-product scores cannot be measured and say so. | |
| _subject | No | The record to act on: exactly one of sequence, accession (+source), sample (an id from list_samples) or file ({name, text} or {name, base64}); record_index picks one record of several. | |
| conditions | No | salt, magnesium, dNTP and oligo concentrations plus the salt-correction method every interaction is measured in. Left unset it is filled from your reaction-conditions settings, and falls back to primer3's defaults when there are none. Advanced. | |
| stringency | No | whose cutoffs decide. `primer3` judges on the Tm limits calibrated for the engine that computes them, which is what the panel opens on; the other three are MultiPLX's own presets, verbatim from cmultiplx 1.4. Values: primer3 (primer3 limits (the engine's own)), high (MultiPLX high stringency), normal (MultiPLX normal), low (MultiPLX low). | primer3 |
Output Schema
| Name | Required | Description | Default |
|---|---|---|---|
| pairs | Yes | every unordered pair: its five MultiPLX scores, its probe interactions, the cutoffs it breaks, whether it is compatible, and why not in words | |
| cutoffs | Yes | the cutoff set the verdicts were judged against, so a report says what it means by compatible | |
| poolable | Yes | true when NO pair clashes, so the whole set can go in one tube. Branch a workflow on this rather than counting the rows | |
| compatible | Yes | assay names that clashed with nothing — the ones that can be pooled | |
| conflicting | Yes | assay names involved in at least one clash |