Skip to main content
Glama

fritzos8-mcp

CI CodeQL PyPI Python versions License: MIT OpenSSF Scorecard OpenSSF Best Practices

English · Deutsch

Let your AI assistant run your FRITZ!Box – safely. An MCP server for AVM FRITZ!Box routers on FRITZ!OS 8: diagnose slow internet, audit security, clean up the device list, manage guest Wi-Fi, telephony and smart home – read-only by default, and every change is verified.

Demo: network doctor, security check and the plan → token → execute safety model

What you can ask

"Why is my internet slow tonight?" Runs the network doctor: line values (SNR margin, errors, resyncs), event log, Wi-Fi and mesh, LAN link flapping, DNS as a single point of failure – and returns findings with severity, likely cause and what to do.

"How secure is my FRITZ!Box?" Security check with a 0–100 score: remote access, MyFRITZ!, port forwards, WPS, Wi-Fi encryption, guest isolation, firmware, DNS over TLS – each finding with the exact menu path to fix it.

"Clean up devices that haven't been online for three months." Finds candidates (long offline, random MACs, duplicates, orphaned static IPs), suggests better names via vendor lookup, shows you the plan and changes nothing until you confirm.

"Turn on guest Wi-Fi for two hours." · "Boost the living room heating for 30 minutes." · "Block this spam number." Write actions – each one is read back from the box and reported as verified: true or false.

Related MCP server: mtik-mcp

Features

  • Diagnostics – network doctor, line diagnostics for DSL, cable, fibre and LTE, per-device connection quality, link-flapping detection, system transparency (TR-069, NTP, IPv6/DS-Lite)

  • Security – scored security check, two-factor status, firmware and update overview for all AVM devices

  • Devices – both device names (TR-064 and web UI), rename, static IP, clean-up assistant, snapshots with diff, Wake-on-LAN, mesh and LAN ports

  • Wi-Fi & family – Wi-Fi channels and settings, guest Wi-Fi with time limit, access profiles, tickets, internet block per device

  • Telephony – call list with reverse lookup, answering machines, phone books, call deflection and barring, alarm clocks

  • Smart home – thermostats, switches, blinds, energy report, routines, holiday periods (REST API, AHA fallback)

  • Monitoring – optional collector for a local measurement series, ISP fault reports, anomaly detection, alerts via webhook, ntfy or Telegram

  • Multi-box – manage several boxes from one server, with a family-admin report across all of them

About 160 tools in total – see the generated tool reference.

Quick start

1. Prepare the box. Enable Home Network › Network › Network Settings › Allow access for applications and create a dedicated user under System › FRITZ!Box Users.

2. Store the password in your OS keychain (or use FRITZ_PASSWORD_FILE with mode 600):

uvx --from 'fritzos8-mcp[keyring]' keyring set fritzos8-mcp <user>

3. Add the server to your client – Claude Code shown. Other clients and Windows/Linux: docs/clients.md. Claude Desktop: install the one-click bundle fritzos8-mcp-<version>.mcpb from the latest release instead – it asks for host, user and password and needs neither step 2 nor a terminal.

claude mcp add fritzos8 -s user -e FRITZ_HOST=fritz.box -e FRITZ_USER=<user> -- \
  uvx --from 'fritzos8-mcp[keyring]' fritzos8-mcp

4. Ask your assistant to run setup_check. It verifies TR-064, the user's rights and two-factor settings, and tells you which tools a missing right would disable.

The server starts read-only. Enable changes with FRITZ_ALLOW_WRITE=1, critical actions additionally with FRITZ_ALLOW_CRITICAL=1.

Safety model

Tier

Enabled by

What it allows

read

always

read-only tools

write

FRITZ_ALLOW_WRITE=1

changes – each one is read back and reports verified

critical

+ FRITZ_ALLOW_CRITICAL=1

reboot, port forwards, firmware update, … only via plan → one-time token → execute, plus a yes/no prompt in clients that support it

  • Never claims success it didn't see. If the result can't be read back, you get verified: false.

  • Never bypasses two-factor confirmation. If the box asks for it, the tool reports confirmation_required and explains how to confirm.

  • Never shows secrets. Passwords, Wi-Fi keys, PINs, session IDs and VPN keys are redacted from every output, error and log line.

  • Protects the box. Throttling, caching and a circuit breaker per box; server_status shows the health of each interface (last success/error, re-logins) even when the client still shows the server as connected.

Details: SECURITY.md.

Works with

  • Boxes: FRITZ!OS 8 – tested on FRITZ!Box 7583 (DSL) and 6660 Cable. Reports for other models are welcome: compatibility.

  • Clients: any MCP client – Claude Code, Claude Desktop, Cursor, VS Code, …

  • Interfaces: TR-064 (via fritzconnection), the AHA and Smart Home REST APIs, and the web UI's /api/v0 – the latter only where TR-064 can't help.

  • Language: tool descriptions and messages are in German; assistants handle them fine in any conversation language.

Not a Home Assistant replacement. For HA entities use the official AVM FRITZ!Box Tools, FRITZ!SmartHome and Call Monitor integrations. This server is for AI assistants – diagnostics, audits and guarded changes. Alerts can be sent to a Home Assistant webhook.

Documentation

Configuration

permissions, all environment variables, multiple boxes, client setup

Tool reference

every tool with tier, required right and parameters

Remote access

Streamable HTTP with bearer token, e.g. on a Raspberry Pi

Interface coverage

what is covered against the official AVM documentation

Compatibility · Fixtures

tested models, contributing anonymized box answers

Contributing

Bug reports, compatibility reports and pull requests are welcome – see CONTRIBUTING.md. make setup installs everything including the git hooks; tests run against mocks only, no box required.

License

MIT. Parts are adapted from MIT-licensed projects, see NOTICE.

Independent project, not affiliated with AVM / FRITZ! GmbH. FRITZ!Box and FRITZ!OS are trademarks of FRITZ! GmbH. The /api/v0 endpoints are undocumented and may change with firmware updates; affected tools then report unsupported_firmware.

Available Tools

79 tools
alarm_clocksB
Read-only

[Stufe: read] Weckrufe der Telefonanlage (TR-064 X_VoIP:X_AVM-DE_GetAlarmClock): an/aus, Name, Uhrzeit, Wochentage, Telefon.

Inputs: box. Returns: object

alarms_checkA
Read-only

[Stufe: read] Alarme prüfen (nur lesend an der Box): neue Geräte, Link-Flapping, Leitungs-Grenzwerte, Batterie schwach, Updates verfügbar, Anomalien der Messreihe (schleichende Verschlechterung), optional Konfig-Abweichung; entprellt (Zustand lokal). Mit notify=true gehen NEUE Alarme an die per Umgebung konfigurierten Kanäle – deren URLs/Tokens werden nie ausgegeben.

Inputs: box, notify, include_drift. Returns: object

avm_device_detailA
Read-only

[Stufe: read] Ein AVM-Gerät im Detail, nur über die Box-Schnittstellen: DECT-Eintrag (X_AVM-DE_Dect:GetSpecificDectEntry), Powerline (X_AVM-DE_Homeplug:GetSpecificDeviceEntry), Hostliste (Modell, Mesh-fähig, Update) und Mesh-Knoten (Rolle, Uplink zur Box mit Rate, Anzahl Clients).

Inputs: device (required), box. Returns: object

avm_device_updatesA
Read-only

[Stufe: read] Update-Übersicht aller AVM-Geräte: FRITZ!Box (FRITZ!OS, Update verfügbar, Auto-Update), Repeater/Mesh- Knoten aus der Hostliste, DECT-Mobilteile und DECT-ULE-Geräte (X_AVM-DE_Dect), Powerline (X_AVM-DE_Homeplug) – je Gerät Modell, aktiv, update_available, letztes Update. Nicht lesbare Teile = available false.

Inputs: box. Returns: object

backup_target_checkA
Read-only

[Stufe: read] Bewertet die FRITZ!Box-NAS als Backup-Ziel: SMB aktiv, NAS-Dienst erreichbar, Internet-FTP aus, freier Platz (per TR-064 nicht lesbar → unknown) → overall ok/warn/fail mit Empfehlungen.

Inputs: box, share, min_free_gb. Returns: object

boxes_overviewA
Read-only

[Stufe: read] Alle konfigurierten FRITZ!Boxen auf einen Blick: Modell, FRITZ!OS, Update verfügbar, Internet verbunden, Kurz-Sicherheitsstatus. Eine nicht erreichbare Box bricht die Übersicht nicht ab.

Inputs: no named parameters. Returns: object

box_speedtest_infoA
Read-only

[Stufe: read] Speedtest-SERVER der Box (TR-064 X_AVM-DE_Speedtest: GetInfo/GetStatistics): TCP/UDP im Heimnetz bzw. aus dem Internet aktiv, Ports, letzte Messung (Mbit/s). Kein Internet-Speedtest (gibt es per TR-064 nicht); warnt, wenn der Server aus dem Internet erreichbar ist.

Inputs: box. Returns: object

call_barring_listA
Read-only

[Stufe: read] Rufsperren (TR-064 X_AVM-DE_OnTel:GetCallBarringList): gesperrte Nummern mit Name und uid.

Inputs: box. Returns: object

call_deflectionsB
Read-only

[Stufe: read] Rufumleitungen (TR-064 X_AVM-DE_OnTel:GetDeflections): an/aus, für welche Anrufe, Ziel, wann.

Inputs: box. Returns: object

call_listA
Read-only

[Stufe: read] Anrufliste (TR-064 X_AVM-DE_OnTel:GetCallList): Datum, Typ, Gegenstelle, Name, Gerät, Dauer. Neueste zuerst; Filter incoming/outgoing/missed/rejected; optional Namen aus den Telefonbüchern. Keine Aufnahmen.

Inputs: box, days, call_type, max_entries, +1 more. Returns: object

compare_boxesA
Read-only

[Stufe: read] Vergleicht einen Aspekt über alle Boxen (dns, security, firmware, wlan, system, wan): Werte je Box und die Felder, in denen sich die Boxen unterscheiden.

Inputs: aspect (required). Returns: object

dect_handsetsB
Read-only

[Stufe: read] DECT-Mobilteile: ID, Name, Modell, aktiv, Firmware-Update verfügbar (X_AVM-DE_Dect) und zugeordnetes Telefonbuch (X_AVM-DE_OnTel:GetDECTHandsetInfo).

Inputs: box. Returns: object

device_connection_qualityA
Read-only

[Stufe: read] Verbindungsqualität je Gerät: WLAN (Signal dBm/%, Band, Kanal, Kanalbreite, aktuelle/max. Rate, Zugangspunkt) bzw. LAN (Port, Speed vs. Maximalrate, EEE) – mit Bewertung gut/ok/schwach und konkreten Tipps. Quellen: Mesh-Liste, TR-064 WLANConfiguration, /api/v0 eth_ports. Schlechteste zuerst.

Inputs: box, mac. Returns: object

devices_change_counterA
Read-only

[Stufe: read] Änderungszähler der Geräteliste (TR-064 Hosts:X_AVM-DE_GetChangeCounter): billiger Indikator, ob sich seit dem letzten Abruf etwas geändert hat (neues Gerät, online/offline) – vor teuren Abfragen nutzen.

Inputs: box. Returns: object

devices_cleanup_reportA
Read-only

[Stufe: read] Aufräum-Assistent (nur lesend): Löschkandidaten (Zufalls-MACs, lange offline, ohne MAC, Namens-Duplikate mit Zufalls-MAC, verwaiste feste IPs; gleiche IP nur als Hinweis, Hersteller-MACs nur bei bekanntem 'zuletzt online' ab der Grenze) und Umbenennungsvorschläge (Hersteller per MAC/IEEE-OUI, Schema Typ-Raum bzw. Hersteller-Modell, nur A–Z a–z 0–9 -), jeweils mit Begründung. Nie vorgeschlagen: Box, geschützte und aktive Geräte, VPN-Gegenstellen (IP im entfernten Netz einer VPN-Verbindung), AVM-Geräte/Mesh-Knoten (auch lokal administrierte AVM-MACs, keine Umbenennung); Einträge ohne MAC nur offline und ohne VPN-Bezug.

Inputs: box, offline_days. Returns: object

dsl_infoA
Read-only

[Stufe: read] DSL-Leitung (TR-064 WANDSLInterfaceConfig:GetInfo): Sync-Raten, max. Raten, SNR-Marge, Dämpfung, Fehlerzähler. Ohne DSL-Anschluss: available=false.

Inputs: box. Returns: object

family_admin_reportA
Read-only

[Stufe: read] Familien-Admin-Bericht über ALLE Boxen: Ampel je Box mit Gründen, erreichbar, Internet, Modell, FRITZ!OS, Updates aller AVM-Geräte, Sicherheits-Score, aktive Alarme, NAS als Backup-Ziel – strukturiert und als Markdown. Nur lesend; eine nicht erreichbare Box bricht den Bericht nicht ab.

Inputs: check_alarms. Returns: object

firmware_statusB
Read-only

[Stufe: read] Installiertes FRITZ!OS und ob ein Update verfügbar ist (TR-064 UserInterface:GetInfo).

Inputs: box. Returns: object

firmware_update_statusA
Read-only

[Stufe: read] FRITZ!OS-Update: installiert, verfügbar, Update-Zustand, letztes Update erfolgreich? (TR-064 UserInterface GetInfo + X_AVM-DE_GetInfo). Nach firmware_update_execute zum Prüfen verwenden.

Inputs: box. Returns: object

fritz_driftA
Read-only

[Stufe: read] FRITZ as Code: vergleicht einen Sollzustand (YAML: guest_wifi, wlan_channels, lan_eee, static_ip, internet_access, parental_profile, tam, dns_dhcp, port_forwards) mit der Box und listet Abweichungen (anwendbar bzw. nur Vergleich). Ändert nichts.

Inputs: box, name, spec. Returns: object

fritz_exportA
Read-only

[Stufe: read] FRITZ as Code: erzeugt aus dem aktuellen Stand einen Sollzustand (YAML) als Ausgangspunkt; optional lokal gespeichert (0600). Ändert an der Box nichts.

Inputs: box, save_as. Returns: object

get_dns_settingsA
Read-only

[Stufe: read] DNS-Einstellungen nur lesend: per DHCP verteilter DNS (TR-064), aktuell genutzte Upstream-DNS IPv4/IPv6 (TR-064), eigene DNS-Server, lokaler DNSv6-Server und DoT laut /api/v0 (unverifiziert). Ändern ist nicht möglich.

Inputs: box. Returns: object

get_lan_dnsB
Read-only

[Stufe: read] DNS-Server, die die FRITZ!Box per DHCP an LAN-Clients verteilt (LANHostConfigManagement:GetDNSServer).

Inputs: box. Returns: object

guest_wifi_sessionB
Read-only

[Stufe: read] Gast-WLAN-Sitzung: an/aus, SSID, laufende Zeitbegrenzung dieses Servers (bis/Restzeit) und die eigene Zeitbegrenzung der Box (nur lesbar). Ohne Schlüssel.

Inputs: box. Returns: object

guest_wifi_statusA
Read-only

[Stufe: read] Gast-WLAN: aktiv, SSID, Verschlüsselung, Clients, Zeitbegrenzung (TR-064). Ohne Schlüssel.

Inputs: box. Returns: object

history_anomaliesA
Read-only

[Stufe: read] Anomalie-Erkennung auf der lokalen Messreihe (keine Box-Abfrage): schleichende Verschlechterung – sinkende DSL-Störabstandsmarge (Trend + Prognose), niedrigere Sync-Rate, schneller wachsende Fehlerzähler, gehäufte Neuverbindungen, häufigere Geräteabbrüche, Geräte, die regelmäßig kurz wegfallen. Vergleicht die letzten recent_hours mit den Tagen davor; zu wenig Daten = 'insufficient_data'. Befunde erscheinen auch in network_doctor und alarms_check.

Inputs: box, days, recent_hours. Returns: object

history_collectA
Read-only

[Stufe: read] Nimmt jetzt einen Messpunkt der Messreihe auf (WAN-Status/Laufzeit, DSL-Raten/SNR/Fehlerzähler, Durchsatz, Geräteanzahl über den Änderungszähler) und speichert ihn NUR LOKAL (SQLite 0600). Ändert an der Box nichts. Für regelmäßige Messung den Collector fritzos8-collector laufen lassen.

Inputs: box. Returns: object

history_queryA
Read-only

[Stufe: read] Zeitreihe einer Messgröße aus der lokalen Messreihe: Punkte (höchstens 500, sonst ausgedünnt), min/max/avg und Messlücken im Zeitraum.

Inputs: metric (required), box, hours. Returns: object

history_summaryA
Read-only

[Stufe: read] Zusammenfassung der lokalen Messreihe: je Messgröße last/min/max/avg (Fehlerzähler mit Zuwachs), Ereignisse (Box-Neustarts, Neuverbindungen, DSL-Resyncs, Geräte online/offline), Messintervall, Lücken, Abdeckung in %.

Inputs: box, hours. Returns: object

internet_access_statusB
Read-only

[Stufe: read] Kindersicherung: ist der Internetzugang eines Geräts gesperrt? (TR-064 X_AVM-DE_HostFilter: GetWANAccessByIP). Gerät per mac ODER ip.

Inputs: ip, box, mac. Returns: object

ipv6_firewall_statusA
Read-only

[Stufe: read] IPv6-Firewall der Box (IGD GetFirewallStatus: an, Pinholes erlaubt) und die über diesen Server angelegten IPv6-Pinholes mit Ablaufzeit (die Box selbst bietet keine Liste).

Inputs: box. Returns: object

isp_reportA
Read-only

[Stufe: read] Störungsprotokoll für den Provider (Markdown) aus der lokalen Messreihe: Ausfälle mit Dauer, Neuverbindungen, Box-Neustarts, DSL-Resyncs (nur bei DSL), Fehlerzähler, Sync-Rate vs. Vertragsrate (X_AVM-DE_TariffDataRate), Messlücken, Hinweis auf die Breitbandmessung der BNetzA. Braucht Daten von fritzos8-collector bzw. history_collect.

Inputs: box, save, date_to, date_from. Returns: object

lan_portsA
Read-only

[Stufe: read] LAN-Ports der Box (/api/v0/generic/eth_ports): Bezeichnung, Funktion (lan/guest/wan), verbunden, Geschwindigkeit vs. Maximalrate, Power-/Green-Mode, EEE-Modus (auto/off) und ob EEE gerade ausgehandelt ist. Hinweis: EEE wirkt auf manchen Modellen box-weit.

Inputs: box. Returns: count, notes, ports, source, +3 more

line_diagnosticsA
Read-only

[Stufe: read] Leitungsdiagnose je Anschlussart (nur lesend): DSL (Raten, SNR, Dämpfung, Fehler, Profil, SNR-Spektrum, automatischer Kabeltest mit Fehlerort), Glasfaser (optische Pegel gegen Alarmschwellen, GPON, Resyncs), Mobilfunk (Technik, RSRP-Bewertung, Zellen ohne Standortdaten, Bänder, SIM-Status), Kabel (per TR-064 unknown). Mit Befunden (Schweregrad, Ursache, Empfehlung).

Inputs: box, include_spectrum. Returns: object

list_hostsB
Read-only

[Stufe: read] Bekannte Hosts laut TR-064 (Hosts): Name, IP, MAC, aktiv, Anschlussart.

Inputs: box, only_active. Returns: object

list_landevicesB
Read-only

[Stufe: read] Geräteeinträge der FRITZ!OS-8-REST-API: uid, name (TR-064), friendly_name (Web-UI), mac, ip, static_dhcp, active, online, deleteable.

Inputs: box, only_active. Returns: count, landevices

list_port_forwardsA
Read-only

[Stufe: read] IPv4-Portfreigaben (TR-064 WAN-Portmapping): Protokoll, externer Port, Ziel-IP/-Name, interner Port, aktiv, Bezeichnung. Optional die Freigabe-/IPv6-Firewall-Listen der Web-UI (roh, unverifiziert).

Inputs: box, include_web_ui_lists. Returns: object

mesh_overviewA
Read-only

[Stufe: read] Mesh-Übersicht (TR-064 Hosts:X_AVM-DE_GetMeshListPath): Mesh-Master, Knoten (Box, Repeater, Powerline), Verbindungen zwischen Knoten, je Gerät Zugangspunkt, LAN/WLAN-Band, Linkrate, Signal (dBm aus der Mesh-Liste bzw. Signal-% aus der WLAN-Geräteliste X_AVM-DE_GetWLANDeviceListPath).

Inputs: box. Returns: object

myfritz_statusA
Read-only

[Stufe: read] MyFRITZ!-Konto (aktiv/registriert/Adresse), über MyFRITZ! freigegebene Dienste, DynDNS (Anbieter, Domain, Status), Fernzugriff (aktiv, Port, HTTPS, Let's Encrypt), Cloud-Fernverwaltung (USP), Rechte des MCP-Benutzers – plus Bewertungen ok/warn/unknown. Nie Passwörter, Benutzernamen oder E-Mail.

Inputs: box. Returns: object

nas_statusA
Read-only

[Stufe: read] NAS der FRITZ!Box (TR-064 X_AVM-DE_Storage/Filelinks/WebDAVClient/Media): SMB, FTP, FTP aus dem Internet, Online-Speicher, geteilte Links (Name/Pfad/Ablauf/Downloads, ohne Link-Token), Mediaserver, DVB-C. Speicherplatz ist per TR-064 nicht lesbar (unknown). Keine Zugangsdaten, kein Dateizugriff.

Inputs: box. Returns: object

network_doctorA
Read-only

[Stufe: read] Netz-Doktor (nur lesend): kombiniert WAN/DSL-Werte (SNR, Dämpfung, Fehler), Ereignisprotokoll (Sync-Verlust, Abbrüche, DNS-Störung, Radar, LAN-Link-Wechsel), WLAN, Mesh, Online-Monitor, LAN-Ports (Link-Flapping, EEE + Raspberry Pi), DNS als Single Point of Failure und optional eine test_my_device- Messung zu Befunden mit Schweregrad, wahrscheinlicher Ursache und Empfehlung. Schwellen = Faustregeln.

Inputs: box, symptom, client_measurement, flap_check_seconds. Returns: note, sources, summary, symptom, +3 more

network_optimizer_effectA
Read-only

[Stufe: read] Netz-Optimierer, Schritt 4 (nur lesend, lokale Messreihe): Wirkung einer Änderung im Vorher/nachher- Vergleich – Geräteabbrüche pro Tag (betroffene Geräte), Neuverbindungen, aktive Geräte, Durchsatz; Urteil improved/worse/unchanged/insufficient_data.

Inputs: box, hours, change_id. Returns: object

network_optimizer_suggestA
Read-only

[Stufe: read] Netz-Optimierer, Schritt 1 (nur lesend): Vorschläge aus WLAN-Einstellungen, LAN-Ports, Mesh, Ereignisprotokoll und Messreihe – WLAN-Kanal (überlappend/fest bei vielen Abbrüchen), EEE aus (Raspberry Pi, Link-Flapping), Bandsteuerung und Repeater-Standort (nur manuell). actionable = über bestehende Schreib-Tools umsetzbar.

Inputs: box, days. Returns: object

online_monitorA
Read-only

[Stufe: read] Aktueller Up-/Down-Durchsatz (TR-064 X_AVM-DE_GetOnlineMonitor) und übertragenes Volumen seit Verbindungsaufbau, mit Einheiten. Tages-/Monatsvolumen ist per TR-064 nicht lesbar.

Inputs: box. Returns: object

parental_device_statusA
Read-only

[Stufe: read] Kindersicherung eines Geräts (TR-064 GetHostEntryByIP): Zugangsprofil, genutzte/maximale Online-Zeit (s), Restzeit, Tickets im Voraus, Ticket-Gültigkeit, Internetzugang granted/denied, manuelle Sperre. Gerät per mac ODER ip.

Inputs: ip, box, mac. Returns: object

parental_profilesA
Read-only

[Stufe: read] Zugangsprofile der Kindersicherung (TR-064 X_AVM-DE_HostFilter:GetFilterProfiles): ID, Name, Typ (Standard/Guest/Unrestricted/Personal), Budget je Wochentag, Budget geteilt, Zeitplan (Wochentag, Uhrzeit, erlauben/sperren). Einheiten teils unverifiziert (siehe units).

Inputs: box. Returns: object

parental_ticket_statusA
Read-only

[Stufe: read] Status eines Kindersicherungs-Tickets (TR-064 GetTicketIDStatus): unmarked, marked (ausgegeben, nicht eingelöst) oder invalid (eingelöst/ungültig).

Inputs: ticket_id (required), box. Returns: object

phonebook_listB
Read-only

[Stufe: read] Telefonbücher (TR-064 X_AVM-DE_OnTel): nur ID, Name und optional Anzahl Kontakte.

Inputs: box, with_counts. Returns: object

phone_numbers_statusA
Read-only

[Stufe: read] Rufnummern der Box (TR-064 X_VoIP:X_AVM-DE_GetNumbers) mit Registrierungsstatus je Internetrufnummer (X_AVM-DE_GetVoIPStatus: registered/not registered/disabled/connected). Ohne SIP-Zugangsdaten.

Inputs: box. Returns: object

powerline_statusA
Read-only

[Stufe: read] Powerline-Adapter (/api/v0/generic/plc): Modell, Status, Kopplung, Firmware/Update, PHY-Raten (Einheit unverifiziert), Green-Mode, LED, Gegenstellen + Hinweise bei niedriger Rate.

Inputs: box. Returns: object

security_checkA
Read-only

[Stufe: read] Sicherheits-Check mit Score 0–100 und je Befund ok/warn/unknown + remediation (Menüpfad): Fernzugriff (+2FA), MyFRITZ!, Portfreigaben, UPnP, TR-064, WPS, WPA-Modus, Gast-WLAN (Verschlüsselung, Isolierung), Firmware (aktuell, Auto-Update), DNS over TLS, feste IPs. Nur lesend.

Inputs: box. Returns: grade, score, checks, counts, +4 more

server_statusA
Read-only

[Stufe: read] Zeigt, welche Sicherheitsstufen aktiv und welche Tools registriert sind, den Box-Schutz je Box (Drosselung, Cache, Schutzschalter) und die Gesundheit je Box: health ok/degraded/down mit Begründung, je Schnittstelle (TR-064, /api/v0, Smart-Home-REST, AHA) letzte erfolgreiche Anfrage und letzter Fehler, Re-Logins und Alter der Web-Sitzung. Ohne probe keine Box-Abfrage (nur bekannter Zustand).

Inputs: probe. Returns: object

setup_checkA
Read-only

[Stufe: read] Einrichtungs-Check (nur lesend): TR-064 erreichbar, Rechte des MCP-Benutzers, anonyme Anmeldung, Standardkennwort, Zusatzbestätigung (2FA), /api/v0, AHA und Smart-Home-REST erreichbar, aktive Stufen – und je fehlendem Recht die Tools, die deshalb nicht funktionieren. Erster Aufruf nach der Installation.

Inputs: box. Returns: object

smarthome_device_statsA
Read-only

[Stufe: read] Verlaufsstatistik eines Smart-Home-Geräts (AHA getbasicdevicestats): Temperatur, Spannung, Leistung, Energie, Luftfeuchte – in °C/V/W/Wh/% umgerechnet.

Inputs: ain (required), box. Returns: object

smarthome_energy_reportA
Read-only

[Stufe: read] Heiz- und Energiebericht (REST): je Thermostat Soll/Ist/Abweichung, Fenster offen, Boost, Urlaub/Sommer, Batterie, nächste Schaltzeit; je Messsteckdose Leistung, Energie, Kosten/CO2 aus den Box-Kennzahlen.

Inputs: box. Returns: object

smarthome_list_devicesA
Read-only

[Stufe: read] Smart-Home-Geräte und -Gruppen (AHA-HTTP getdevicelistinfos): Name, AIN, Typ, Funktionen, erreichbar, Schaltzustand, Temperatur, Leistung/Energie, Thermostat-Soll/Ist. Leere Liste = keine Geräte.

Inputs: box. Returns: object

smarthome_overviewA
Read-only

[Stufe: read] Smart Home über die REST-API (FRITZ!OS ≥ 8.2): Geräte (Produkt, verbunden, Batterie, Firmware/Update), Einheiten mit Werten (Thermostat Soll/Komfort/Absenk, Boost, Fenster offen, Urlaub/Sommer, nächste Änderung; Temperatur, Luftfeuchte, Schalter, Leistung/Energie, Rollo, Melder), Gruppen, Vorlagen, Routinen, globale Werte (ohne Standort). Ältere Boxen: smarthome_list_devices (AHA).

Inputs: box. Returns: object

smarthome_pairing_statusA
Read-only

[Stufe: read] Status der Geräteanmeldung (REST connect/subscriptionState bzw. AHA getsubscriptionstate); ohne subscription_uid die Funkbasen mit laufender Anmeldung. Gibt nie Pairing-/Install-Codes aus.

Inputs: box, subscription_uid. Returns: object

smarthome_thermostat_configB
Read-only

[Stufe: read] Thermostat-Konfiguration (Smart-Home-REST configuration/units): Komfort/Absenk, Urlaubszeiträume mit Temperatur, Sommerzeit, Fenster-offen-Einstellungen. Datumsangaben jährlich (TT.MM.).

Inputs: uid (required), box. Returns: object

smarthome_tr064_devicesA
Read-only

[Stufe: read] Smart-Home-Geräte über TR-064 (X_AVM-DE_Homeauto, ohne Web-Anmeldung) – Fallback, wenn REST/AHA nicht nutzbar sind: AIN, Name, Produkt, verbunden, Schalter, Leistung/Energie, Temperatur, Thermostat.

Inputs: box. Returns: object

smarthome_unitA
Read-only

[Stufe: read] Eine Smart-Home-Einheit im Detail (REST overview/units/{UID}): Werte, Zeitschaltung/Heizplan (wie von der Box geliefert) und Statistik (Temperatur, Luftfeuchte, Leistung, Energie je Zeitraum).

Inputs: uid (required), box. Returns: object

snapshot_createA
Read-only

[Stufe: read] Konfigurations-Schnappschuss: liest Einstellungen (System/Firmware, WAN-Typ, DNS, WLAN ohne Schlüssel, Gastnetz, Portfreigaben, Fernzugriff/MyFRITZ!/UPnP/WPS, feste IPs, Internetsperren, Smart-Home-Liste, Geräteinventar) und speichert sie NUR LOKAL als JSON (0600). Ändert an der Box nichts; keine Messwerte.

Inputs: box, label. Returns: object

snapshot_diffA
Read-only

[Stufe: read] Vergleicht zwei Schnappschüsse bzw. Schnappschuss und Live-Zustand: geändert/neu/entfernt je Kategorie plus Kurzfassung in Klartext (neue Portfreigabe, unbekanntes Gerät, DNSv6 geändert …). Messwerte und Zähler zählen nicht als Änderung.

Inputs: a, b, box. Returns: object

snapshot_listA
Read-only

[Stufe: read] Lokal gespeicherte Schnappschüsse dieser Box (neueste zuerst).

Inputs: box. Returns: object

system_infoB
Read-only

[Stufe: read] Modell, FRITZ!OS-Version, Hardware-Version und Laufzeit (TR-064 DeviceInfo:GetInfo).

Inputs: box. Returns: model, uptime_s, description, manufacturer, +2 more

system_logA
Read-only

[Stufe: read] Ereignisprotokoll der FRITZ!Box (TR-064 DeviceInfo:GetDeviceLog), optional nach Text gefiltert.

Inputs: box, count, text_filter. Returns: object

system_transparencyB
Read-only

[Stufe: read] System-Transparenz (nur lesend): Provider-Fernwartung TR-069 (aktiv, Server, Firmware durch Provider), Zeit/NTP mit Abweichung zur Uhr dieses Rechners, IPv6 (Verbindungsstatus, Präfix + Lebensdauer, DS-Lite, IPv6-Firewall), statische Routen, Verlegung der Zwangstrennung, Auto-Update-Modus.

Inputs: box. Returns: object

tam_listA
Read-only

[Stufe: read] Anrufbeantworter (TR-064 X_AVM-DE_TAM): Name, aktiv, Anzahl Nachrichten/neue Nachrichten, Speicher. Keine Audio-Downloads.

Inputs: box. Returns: object

test_my_deviceA
Read-only

[Stufe: read] Testet DIESEN Rechner (auf dem der MCP läuft): Latenz/Jitter/Verlust zur Box (TCP-Connect 80/49000, kein Root), DNS-Antwortzeit gegen den von der Box verteilten und einen öffentlichen DNS, HTTP-Download- Durchsatz (kleine Datenmenge) – und vergleicht mit der Sicht der Box (eigene IP → Gerät → WLAN-Signal/ Band/Rate bzw. LAN-Port). Ergebnis 'for_network_doctor' kann an network_doctor übergeben werden.

Inputs: box, count, dns_name, download, +3 more. Returns: object

tr064_callA
Read-only

[Stufe: read] Generischer TR-064-Aufruf – in Stufe 1 nur lesende Actions; Neustart, Reset, Reconnect, Konfig-Import/-Export und Zugangsdaten-Abfragen sind gesperrt. Geheimnisse werden geschwärzt.

Inputs: action (required), service_name (required), box, arguments. Returns: object

tr064_describe_actionB
Read-only

[Stufe: read] Argumente (Richtung, Datentyp, erlaubte Werte) einer TR-064-Action aus der SCPD.

Inputs: action (required), service_name (required), box. Returns: object

tr064_list_servicesA
Read-only

[Stufe: read] Alle TR-064-Services der Box mit den per tr064_call erlaubten lesenden Actions.

Inputs: box. Returns: object

two_factor_statusA
Read-only

[Stufe: read] Zusatzbestätigung (2FA) der Box: aktiv?, aktueller Zustand (wartet/bestätigt/blockiert …) und wie der Mensch an der Box bestätigt (TR-064 X_AVM-DE_Auth GetInfo/GetState). Startet oder umgeht nie etwas.

Inputs: box. Returns: object

vpn_connectionsA
Read-only

[Stufe: read] VPN-Verbindungen der Box (/api/v0/generic/vpn): Name, Typ WireGuard/IPSec, Zustand, aktiviert, verbunden seit (ISO), Gegenstelle, lokale/entfernte Netze, aktiver Fehler bzw. bei verbundener Verbindung letzter (historischer) Fehler – Codes roh, undokumentiert –, WireGuard-Port. Gibt NIE Schlüssel, Pre-Shared-Keys, Konfigurationen oder Zugangsdaten aus.

Inputs: box. Returns: note, count, active, source, +3 more

vpn_statusB
Read-only

[Stufe: read] MyFRITZ!-, Fernzugriffs- und DynDNS-Status (TR-064) plus WireGuard/IPSec-Verbindungen aus /api/v0/generic/vpn (wie vpn_connections; ohne /api/v0 = unknown). Gibt nie Schlüssel, Passwörter oder VPN-Konfigurationen aus.

Inputs: box. Returns: object

wan_statusA
Read-only

[Stufe: read] Internet-Verbindung: Status, Laufzeit, Zugangsart, Leitungsrate, externe IPv4/IPv6 (TR-064).

Inputs: box. Returns: link, ipv4_note, connection, external_ipv4, +1 more

wlan_settingsA
Read-only

[Stufe: read] WLAN-Einstellungen je Funkband (TR-064 WLANConfiguration): Kanal, Autokanal, mögliche Kanäle, DFS-Kanal ja/nein, Standard; WLAN global an/aus; Nachtschaltung/WLAN-Zeitplan (X_AVM-DE_GetNightControl). Bandsteuerung und Kanalbandbreite sind per TR-064 nicht lesbar (unknown). Keine Schlüssel.

Inputs: box, include_web_ui. Returns: object

wlan_statusA
Read-only

[Stufe: read] Alle WLANs (TR-064 WLANConfiguration1..n): aktiv, SSID, Band, Kanal, Standard, Verschlüsselung, Anzahl verbundener Clients, Gast ja/nein. Gibt NIE WLAN-Schlüssel aus.

Inputs: box. Returns: note, count, networks

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    TDQS

    B3.2/5.0

    Scored across 79 tools

    Disambiguation2/5

    The surface contains multiple clusters of near-duplicate tools: smart home is covered by smarthome_list_devices, smarthome_overview, smarthome_tr064_devices, smarthome_unit and smarthome_device_stats; firmware by firmware_status, firmware_update_status and avm_device_updates; DNS by get_dns_settings and get_lan_dns; WLAN by wlan_status and wlan_settings; VPN by vpn_status and vpn_connections. The descriptions explain transport differences (REST vs AHA vs TR-064) and are honest about fallbacks, but an agent must read the fine print to pick correctly between e.g. wlan_status and wlan_settings or smarthome_list_devices and smarthome_overview.

    Naming Consistency4/5

    Every name is lowercase snake_case, which gives a uniform, predictable look, and domain prefixes (smarthome_, wlan_, parental_, snapshot_, history_, tr064_) group related tools readably. The only deviation is the mix of verb_noun (list_hosts, get_dns_settings, compare_boxes) and noun_status/noun_report patterns (wan_status, dsl_info, mesh_overview), but this is a minor stylistic inconsistency rather than confusion.

    Tool Count2/5

    79 tools is far beyond a well-scoped set and, since every tool is read-only, the surface explodes into many narrowly sliced read views (four history tools, five smart-home views, three firmware views, five diagnostic reports). Several reports (family_admin_report, security_check, network_doctor, network_optimizer_suggest, network_optimizer_effect, devices_cleanup_report) overlap heavily in the data they aggregate, so the count feels bloated rather than earned.

    Completeness2/5

    Read coverage is unusually broad, but the whole surface is read-only: there is no tool to change WLAN settings, edit port forwards, manage parental profiles, create snapshots from YAML, or apply the suggestions that fritz_drift and network_optimizer_suggest explicitly say are 'actionable via existing write tools'. There are also dangling references to tools that are not present (firmware_update_execute), which will cause dead ends for any agent asked to actually configure the box.

    Maintenance

    ActivityMaintained
    ResponsivenessNo recent community issues

    Related MCP Connectors

    Related MCP Servers

    • A
      license
      C
      quality
      B
      maintenance
      Enables AI assistants to operate a DrayTek Vigor 3912S router through the full DrayOS CLI, with read-only tools by default and two-step confirm-gated writes. It also provides SQLite audit logging and safety controls like host-key pinning and command blocklists.
      217
      MIT
    • A
      license
      Not graded
      quality
      B
      maintenance
      Enables AI assistants to audit, inspect, and safely configure MikroTik RouterOS v7 routers through tools for connection testing, system status, security audits, firewall mangle management, routing, DHCP leases, sanitized exports, containers, and adlist queries.
      22 npm
      GPL 3.0
    • A
      license
      Not graded
      quality
      B
      maintenance
      Enables AI copilots and autonomous agents to inspect, diagnose, and safely manage TP-Link 4G/LTE gateways and broadband routers through typed MCP tools for status, signal, clients, Wi-Fi, DNS, SMS/USSD, and guarded mutations. It provides session leasing and confirmation safeguards to avoid locking out admins or disconnecting active sessions.
      MIT