Skip to main content
Glama

Dell iDRAC MCP

CI Latest release License: MIT

A Model Context Protocol server for the Dell iDRAC 8, the out-of-band management controller in 13th-generation PowerEdge servers (T430, T630, R430, R530, R630, R730, R730xd, ...). It lets an AI assistant answer questions about your server's hardware and health, and, if you allow it, power it on, restart it or change BIOS settings.

It talks directly to the iDRAC's Redfish API over your local network. There is no cloud service, no Dell account and no agent on the server. It works even when the operating system is down or the server is off.

Ships as a one-click .mcpb extension for Claude Desktop, and runs as a plain Node.js server for any other MCP client.

This is an independent community project. It is not affiliated with or endorsed by Dell Technologies.


What you can ask

Is my server healthy? Anything I should worry about? How warm is it inside, and how fast are the fans spinning? How much power is the server drawing right now, and what was the peak? Are any of my disks predicted to fail? What RAID level is the data volume? What happened on the server last night? Show me the event log. Which firmware versions are installed, and is the iDRAC firmware current? Is virtualization enabled in the BIOS? Shut the server down cleanly and tell me when it's off. (needs operator mode) Boot from the network once and restart. (needs operator mode) Turn on the identify LED so I can find the machine. (needs operator mode)

Related MCP server: Redfish MCP Server

Highlights

  • Health at a glance: one call checks CPUs, memory, fans, temperatures, power supplies, voltages, RAID controllers, disks and volumes, and reports only what needs attention, together with recent warnings from the event log.

  • Full inventory: processors, DIMMs, disks with predicted failure and SSD wear, virtual disks, network ports, iDRAC network settings and services, and firmware versions of every component.

  • Logs and jobs: the System Event Log and the Lifecycle Controller log, newest first, filterable by severity or text, and the iDRAC job queue.

  • Settings: BIOS attributes with their allowed values and help text, boot mode and boot order, virtual media, and a full Server Configuration Profile export.

  • Safe by default: three permission modes that mirror the iDRAC roles. Read-only is the default; tools you have not enabled are never even listed.

  • Kind to the iDRAC: one Redfish session per run (no login entry in the Lifecycle log for every request), logout on exit, limited concurrency for the slow iDRAC 8, and no retry loop on a wrong password, so you cannot lock yourself out.

  • Built on real hardware: developed and tested against a PowerEdge T430 running the final iDRAC 8 firmware, including its Redfish quirks (the one $expand syntax it accepts, log service ids that differ from their URIs, ports that are listed but missing).

  • Escape hatch: idrac_get reads any Redfish resource; idrac_raw_request (admin) sends anything.


Requirements

  • A Dell PowerEdge server with iDRAC 8, firmware 2.40 or newer. 2.70 or newer is recommended; 2.86.86.86 is the final iDRAC 8 release.

  • The iDRAC must be reachable over HTTPS (port 443) from the computer running the MCP client.

  • Redfish enabled on the iDRAC. It is on by default (iDRAC Settings → Services → Redfish).

  • Any iDRAC license works (Basic, Express or Enterprise). Virtual media requires Enterprise.

  • Node.js 20 or newer, only for the npx or source install. The .mcpb extension uses the runtime built into Claude Desktop.


Install

Option A — Claude Desktop extension (.mcpb)

  1. Download dell-idrac-mcp-<version>.mcpb from the latest release.

  2. Double-click the file, or open Claude Desktop → Settings → Extensions and drag it in.

  3. Fill in the iDRAC address, user name and password, and choose whether to allow actions or configuration changes.

  4. Start a new chat and ask "Is my server healthy?"

Everything is bundled into one file, so no separate Node.js installation is needed.

The npx examples below use the npm package. Until it is published to npm you can point npx straight at the repository instead: npx -y github:mbgroen/dell-idrac-mcp.

Option B — Claude Code

claude mcp add dell-idrac --scope user \
  --env IDRAC_HOST=192.168.0.80 \
  --env IDRAC_USERNAME=claude \
  --env IDRAC_PASSWORD='your-password' \
  -- npx -y @mbgroen/dell-idrac-mcp

Option C — any other MCP client

Add this to the client's MCP server configuration (Cursor, VS Code, Windsurf, Zed, custom hosts):

{
  "mcpServers": {
    "dell-idrac": {
      "command": "npx",
      "args": ["-y", "@mbgroen/dell-idrac-mcp"],
      "env": {
        "IDRAC_HOST": "192.168.0.80",
        "IDRAC_USERNAME": "claude",
        "IDRAC_PASSWORD": "your-password",
        "IDRAC_PERMISSION_MODE": "read-only"
      }
    }
  }
}

Option D — from source

git clone https://github.com/mbgroen/dell-idrac-mcp.git
cd dell-idrac-mcp
npm install            # also compiles TypeScript
cp .env.example .env   # fill in host, user and password
npm run test:live      # optional: read-only check against your iDRAC
node dist/index.js     # speaks MCP over stdio

Create a dedicated iDRAC user

You can use root, but a dedicated account limits what the assistant can do even if this server's own checks were bypassed, and it makes the assistant's activity easy to recognise in the Lifecycle log.

  1. Open the iDRAC web interface and go to iDRAC Settings → User Authentication → Local Users.

  2. Click a free user ID and choose Configure User.

  3. Enter a user name (for example claude) and a strong password, and enable the user.

  4. Under iDRAC User Privileges, pick the role that matches the permission mode you plan to use:

Permission mode

iDRAC role

Why

read-only

Read Only

Login is all that reading needs.

operator

Operator

Server control (power, LED) and configure privileges.

admin

Administrator

Clearing logs and some configuration changes need it.

IPMI and serial-over-LAN privileges are not used and can stay at No Access. The iDRAC enforces its own privileges as well: if a tool fails with HTTP 403, the account lacks a privilege for that operation.


Permission modes

The server only lists the tools its mode allows, and checks the mode again on every call.

Mode

IDRAC_PERMISSION_MODE

Extension toggle

What it adds

Read-only (default)

read-only

both off

Inventory, health, sensors, logs, jobs, BIOS/boot/virtual media settings, configuration export. Nothing can change.

Operator

operator

Allow power control and other actions

Power on, graceful shutdown or restart, force off, power cycle, NMI; identify LED; one-time boot device; attach or detach virtual media; restart the iDRAC; delete jobs.

Admin

admin

Allow configuration changes

Change BIOS settings (staged in a configuration job), clear the System Event Log, raw Redfish write requests.

Start with read-only. A power action affects everything that runs on the server: the assistant is instructed to confirm before turning it off or restarting it, and Claude Desktop asks for your approval before each tool call unless you turn that off.


Tools

Read-only

Tool

What it does

idrac_status

Connection check: iDRAC firmware (with a note when newer firmware exists), Redfish version, model, service tag, permission mode. Use it first when something fails.

idrac_system_overview

Model, service tag, BIOS and iDRAC versions, power state, health, CPU and memory totals, power draw and inlet temperature.

idrac_health

Checks every subsystem and lists only unhealthy components, plus recent warning and critical events.

idrac_thermal

Fan speeds, temperatures with thresholds, fan redundancy.

idrac_power

Current, average, minimum and peak power, power cap, power supplies, redundancy, optionally voltages.

idrac_processors

CPUs: model, cores, threads, speed, health.

idrac_memory

DIMMs: slot, size, type, speed, manufacturer, part number, health.

idrac_storage

RAID and other controllers, physical disks (predicted failure, SSD wear), virtual disks.

idrac_network_interfaces

Server network ports (MAC, link, speed) and the iDRAC's IP configuration.

idrac_firmware_inventory

Firmware versions of all components, optionally including rollback versions.

idrac_manager_info

iDRAC firmware, time, enabled services and ports (HTTPS, SSH, IPMI, SNMP, ...), NTP, open sessions.

idrac_logs

System Event Log (sel) or Lifecycle log (lclog), newest first, filter by severity or text.

idrac_list_jobs

The iDRAC job queue, or one job by id.

idrac_bios_attributes

BIOS settings by text or name, pending changes, and (with describe) allowed values and help text.

idrac_boot_settings

Boot mode, boot order, one-time boot override and its allowed targets.

idrac_virtual_media

Virtual CD/removable disk state and whether attaching images is supported.

idrac_export_config

Server Configuration Profile export (XML), optionally saved to a file. Includes iDRAC settings that have no other Redfish view, such as the thermal profile.

idrac_get

GET any resource under /redfish/v1, with optional $expand and $select.

Operator

Tool

What it does

idrac_power_action

On, GracefulShutdown, GracefulRestart, ForceOff, ForceRestart, PowerCycle, PushPowerButton, Nmi; optionally waits for the new power state. Firmware without GracefulShutdown gets an ACPI power-button press instead.

idrac_set_identify_led

Identify LED on, blinking or off.

idrac_set_boot_override

One-time (or continuous) boot from PXE, virtual CD, BIOS setup, ...; None clears it.

idrac_virtual_media_insert

Attach an ISO or image from an HTTP(S), NFS or CIFS URL, where the firmware supports it.

idrac_virtual_media_eject

Detach virtual media.

idrac_reset_idrac

Restart the iDRAC (the server keeps running).

idrac_delete_job

Remove a job from the queue, for example a scheduled BIOS change.

Admin

Tool

What it does

idrac_set_bios_attributes

Validate and stage BIOS changes, create the configuration job, and apply at the next reboot or reboot now.

idrac_clear_log

Clear the System Event Log.

idrac_raw_request

Any GET, POST, PATCH or DELETE under /redfish/v1.


Configuration reference

All settings are environment variables. The .mcpb extension sets them from its settings panel.

Variable

Default

Description

IDRAC_HOST

(required)

Host name or IP of the iDRAC. https:// is assumed; a port may be added (10.0.0.5:8443).

IDRAC_USERNAME

(required)

iDRAC user name.

IDRAC_PASSWORD

(required)

iDRAC password.

IDRAC_PERMISSION_MODE

read-only

read-only, operator or admin.

IDRAC_ALLOW_ACTIONS

false

true selects operator mode (used by the extension).

IDRAC_ALLOW_CONFIG

false

true selects admin mode (used by the extension).

IDRAC_VERIFY_TLS

false

Verify the iDRAC's TLS certificate.

IDRAC_TIMEOUT_SECONDS

60

Per-request timeout.

IDRAC_AUTH_MODE

session

session (X-Auth-Token) or basic (HTTP Basic on every request).

IDRAC_MAX_CONCURRENCY

4

Maximum parallel requests to the iDRAC.


Security notes

  • The server connects only to the iDRAC you configure. Nothing is sent anywhere else.

  • In Claude Desktop the password is stored by the app in your operating system's secure storage and passed to the server at start-up. The server never includes it in tool output or logs.

  • The iDRAC's self-signed certificate is accepted by default; this exception applies only to this server's own connection to the iDRAC. Install a trusted certificate and enable Verify TLS certificate to remove it.

  • A rejected login is not retried for 60 seconds, so a wrong password cannot trigger the iDRAC's IP blocking.

  • iDRAC 8 no longer receives security updates. Keep it on a management network or VLAN that is not reachable from the internet.

  • An assistant acts on what it reads. Log messages and asset tags come from the server itself; keep operator and admin modes off unless you need them.

See SECURITY.md for how to report a vulnerability.


Troubleshooting

Symptom

What to do

did not return a Redfish service root

IDRAC_HOST must be the iDRAC's address, not the server's OS. Check that Redfish is enabled (racadm set iDRAC.Redfish.Enable 1).

The iDRAC rejected the credentials

Check user name and password, and that the user is enabled. The server waits 60 seconds before trying again.

EHOSTUNREACH on macOS while ping works

macOS asks apps for permission to reach devices on the local network. Allow Claude under System Settings → Privacy & Security → Local Network, then try again.

Timeouts

iDRAC 8 is slow, especially just after it restarts. Raise the timeout. If the iDRAC stays unresponsive, restart it with idrac_reset_idrac or racadm racreset.

HTTP 404 for a resource

Older firmware exposes fewer Redfish resources. Update the iDRAC to 2.86.86.86 (iDRAC web interface → Maintenance → System Update).

HTTP 403

The iDRAC user's role lacks a privilege for this operation. See Create a dedicated iDRAC user.

No power readings

Servers with a cabled, non-redundant power supply (an option on the T430) have no power monitoring. Hot-plug power supplies report readings.

A power cap is shown but the server draws more

iDRAC 8 reports the configured cap value even when power capping is disabled. idrac_power labels it power_cap_setting_watts; whether capping is enabled is in iDRAC Settings → Power Configuration (or ServerPwr.1#PowerCapSetting in idrac_export_config).

Virtual media insert not supported

Older iDRAC 8 firmware exposes virtual media read-only through Redfish; 2.86 supports attaching images. Otherwise use the iDRAC web interface or racadm remoteimage.

Fan speeds cannot be changed

iDRAC 8 has no fan control through Redfish. This server only reads fan data, so it works alongside IPMI-based fan scripts.


Development

npm install
npm run build          # compile TypeScript to dist/
npm run typecheck
npm test               # smoke test + end-to-end test against a mock iDRAC 8
npm run test:live      # read-only test against the iDRAC in .env
npm run inspect        # open the MCP Inspector
npm run bundle         # build dell-idrac-mcp-<version>.mcpb

The mock iDRAC (scripts/mock-idrac.mjs) imitates an iDRAC 8 (firmware 2.86) on a PowerEdge T430: session login, $expand, paged logs with both orderings, actions, PATCH, an SCP export job, and the quirks of the real firmware. Run it on its own with node scripts/mock-idrac.mjs and point IDRAC_HOST at http://127.0.0.1:8443 (user root, password calvin) to try changes without touching real hardware.

Project layout:

src/
  index.ts              MCP server: tool registration, permission checks, shutdown
  config.ts             environment variables and permission modes
  redfish/client.ts     HTTP client: sessions, TLS, concurrency, paging, errors
  redfish/resources.ts  resource discovery and output shaping
  tools/                tool definitions, grouped by area
scripts/                build, tests, mock iDRAC
manifest.json           Claude Desktop extension manifest (tool list synced on build)

Releasing

Versions follow semantic versioning: major for breaking changes, minor for new features, patch for fixes.

  1. Bump version in package.json and add a section to CHANGELOG.md.

  2. Run npm run bundle; it syncs the version and tool list into manifest.json.

  3. Commit, then tag and push: git tag -a v1.1.0 -m "v1.1.0" && git push --follow-tags.

The release workflow runs the tests, builds the .mcpb and an npm tarball, and attaches both with checksums to the GitHub release. It also publishes to npm when an NPM_TOKEN secret is configured.


Compatibility

Controller

Servers

Status

iDRAC 8, firmware 2.70 – 2.86

PowerEdge 13th generation (x30)

Supported. Tested on a PowerEdge T430 with iDRAC 8 2.86.86.86.

iDRAC 8, firmware 2.40 – 2.6x

PowerEdge 13th generation

Should work; some resources (storage, logs, export) may be missing.

iDRAC 9

PowerEdge 14th generation and later

Untested. Uses the same standard Redfish paths, so most read tools are expected to work.

iDRAC 7

PowerEdge 12th generation

Not supported (very limited Redfish).

Reports from other models and firmware versions are welcome. Please open an issue with the output of idrac_status.


License

MIT © mbgroen

Dell, PowerEdge and iDRAC are trademarks of Dell Inc. or its subsidiaries.

Available Tools

18 tools
idrac_bios_attributesBIOS settingsA
Read-onlyIdempotent

Read the current BIOS settings (attribute names and values), filtered by text or exact names, plus any changes pending for the next reboot. With describe=true the allowed values and help text are included (slow the first time).

Inputs: names, search, describe.

idrac_boot_settingsBoot settingsA
Read-onlyIdempotent

Show the boot mode (UEFI or BIOS), the boot order, and any one-time boot override with the targets that can be used for it (PXE, virtual CD, BIOS setup, ...).

Inputs: no named parameters.

idrac_export_configExport configuration (SCP)A
Read-only

Export the Server Configuration Profile: every iDRAC, BIOS, NIC and RAID setting as XML. Useful as a backup, to compare settings, or to read iDRAC settings such as thermal profiles that have no other Redfish view. Runs as a short export job on the iDRAC (no settings change); takes 30-120 seconds.

Inputs: format, target, max_chars, save_path.

idrac_firmware_inventoryFirmware inventoryA
Read-onlyIdempotent

List firmware versions of the iDRAC, BIOS, Lifecycle Controller, RAID controller, NICs, disks, power supplies and other components. Previous (rollback) versions are hidden unless include_previous is true.

Inputs: search, include_previous.

idrac_getRead any Redfish resourceA
Read-onlyIdempotent

GET any Redfish resource on the iDRAC by path, e.g. /redfish/v1/Chassis/System.Embedded.1/Power. Use it for data the dedicated tools do not cover. Responses are returned as JSON and truncated at max_chars.

Inputs: path (required), expand, select, max_chars.

idrac_healthHealth checkA
Read-onlyIdempotent

Check every subsystem (CPUs, memory, fans, temperatures, power supplies, voltages, storage) and list only what is not healthy, plus the most recent warning or critical events from the System Event Log.

Inputs: recent_events, include_storage.

idrac_list_jobsJob queueA
Read-onlyIdempotent

List the iDRAC job queue (BIOS and RAID configuration jobs, firmware updates, exports) with state and progress, or get one job by id.

Inputs: limit, state, job_id.

idrac_logsEvent logsA
Read-onlyIdempotent

Read recent entries, newest first, from the System Event Log ('sel': hardware events such as sensor alarms, power and memory errors) or the Lifecycle Controller log ('lclog': configuration changes, firmware updates, logins, jobs). Filter by minimum severity or text.

Inputs: log, limit, search, min_severity.

idrac_manager_infoiDRAC details and servicesA
Read-onlyIdempotent

Details of the iDRAC itself: firmware, date and time, which network services are enabled (HTTPS, SSH, IPMI over LAN, SNMP, virtual console/media) with their ports, NTP servers and the number of open Redfish sessions.

Inputs: no named parameters.

idrac_memoryMemory modulesA
Read-onlyIdempotent

List memory modules (DIMMs) with slot, size, type, speed, manufacturer, part number and health. Empty slots are hidden unless include_empty is true.

Inputs: include_empty.

idrac_network_interfacesNetwork interfacesA
Read-onlyIdempotent

List the server's network ports (MAC, link state, speed) and the iDRAC's own network settings (IP address, gateway, DNS servers, host name).

Inputs: no named parameters.

idrac_powerPower consumption and suppliesA
Read-onlyIdempotent

Current, average, minimum and peak power consumption, power cap, and the power supplies (model, capacity, input voltage, firmware, health) with redundancy. Optionally the voltage sensors.

Inputs: include_voltages.

idrac_processorsProcessorsA
Read-onlyIdempotent

List the installed CPUs with model, cores, threads, speed and health.

Inputs: no named parameters.

idrac_statusConnection statusA
Read-onlyIdempotent

Check the connection to the iDRAC and report its firmware, Redfish version, the server model and service tag, and this MCP server's permission mode. Use this first when another tool fails or to confirm the setup works.

Inputs: no named parameters.

idrac_storageStorage controllers, disks and volumesA
Read-onlyIdempotent

List storage controllers (PERC RAID and others), their physical disks (model, size, media type, health, predicted failure, SSD wear) and virtual disks (RAID level, size, state). Can take a while on iDRAC 8.

Inputs: include_drives, include_volumes.

idrac_system_overviewSystem overviewA
Read-onlyIdempotent

One-call summary of the server: model, service tag, BIOS and iDRAC firmware, power state, overall health, CPU and memory totals, current power draw and inlet temperature. A good starting point for most questions.

Inputs: no named parameters.

idrac_thermalFans and temperaturesA
Read-onlyIdempotent

Current fan speeds (RPM) and temperature readings (inlet, exhaust, CPUs) with their warning and critical thresholds and fan redundancy. Read-only: iDRAC 8 offers no Redfish fan-speed control.

Inputs: include_thresholds.

idrac_virtual_mediaVirtual mediaA
Read-onlyIdempotent

Show the iDRAC virtual media devices (virtual CD/DVD and removable disk): whether an image is attached, which one, and whether this firmware supports attaching images through Redfish.

Inputs: no named parameters.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    TDQS

    A3.8/5.0

    Scored across 18 tools

    Disambiguation4/5

    Most tools target clearly distinct iDRAC resources or subsystems, and the generic idrac_get is explicitly positioned as a fallback for uncovered data. There is some potential confusion among idrac_status, idrac_system_overview, and idrac_manager_info, plus mild overlap between health, thermal, and power reporting, but their descriptions provide enough separation.

    Naming Consistency4/5

    All names use the consistent idrac_ prefix and snake_case, making the set predictable and readable. The only minor inconsistency is that most tools are resource nouns while a few use action-first forms such as idrac_get, idrac_list_jobs, and idrac_export_config.

    Tool Count4/5

    Eighteen tools is on the heavier side for the 3-15 typical range, but the iDRAC domain is broad and each tool covers a meaningful subsystem or operation. The count is reasonable for comprehensive read-only server diagnostics, though a few reporting tools could arguably be consolidated.

    Completeness3/5

    The server covers monitoring comprehensively: system overview, hardware inventory, health, thermal, power, logs, jobs, BIOS reads, boot settings, virtual media state, network interfaces, and config export. However, it lacks lifecycle/control operations such as power actions, BIOS setting writes, virtual media attach, job creation/deletion, firmware updates, and iDRAC/user management, leaving notable gaps if an agent needs to change or operate the server.

    Maintenance

    ActivityNo data
    ResponsivenessOutdated data

    Related MCP Connectors