Skip to main content
Glama

proliant-mcp

proliant-mcp turns AI agents into your assistant for managing HPE compute: HPE ProLiant servers (iLO), HPE Compute Ops Management (GreenLake) and HPE Synergy / OneView, all from one conversation. It's an MCP server for Claude, GitHub Copilot, Codex and other AI assistants. Describe what you want in plain English instead of remembering which GUI screen or CLI command does it.

Ask things like "which servers in Compute Ops Management are critical and why", "show a table of each server's storage controller and GPU" or "any active OneView alerts on the Synergy frame".

Install

Option 1: ask your AI agent

Paste this into your AI agent (Claude, GitHub Copilot, Codex, ...):

Install the proliant-mcp MCP server for me. Follow the instructions at https://raw.githubusercontent.com/hjma29/proliant-mcp/main/AGENTS.md (install uv first if it is missing), then tell me when to restart you.

Option 2: manual

Step 1. Install uv (no admin rights, no git needed).

Windows (PowerShell):

powershell -ExecutionPolicy ByPass -c "irm https://astral.sh/uv/install.ps1 | iex"

macOS:

curl -LsSf https://astral.sh/uv/install.sh | sh

Step 2. Add proliant to your AI client, then restart it.

  • VS Code (GitHub Copilot): open View > Command Palette, run MCP: Open User Configuration, pick Copilot Global, then paste this and save:

    {"mcpServers": {"proliant": {"type": "stdio", "command": "uvx", "args": ["--python", "3.13", "proliant-mcp@latest"], "tools": ["*"]}}}
  • Claude Desktop: Settings > Developer > Edit Config: {"mcpServers": {"proliant": {"command": "uvx", "args": ["--python", "3.13", "proliant-mcp@latest"]}}}

  • Claude Code: claude mcp add --scope user proliant -- uvx --python 3.13 proliant-mcp@latest

  • Any client with an "Add MCP server" form (name, transport, command, args, environment): fill it in like this, then restart the client.

    Field

    Value

    Name

    proliant (any name you like)

    Transport

    stdio

    Command

    uvx

    Args

    --python 3.13 proliant-mcp@latest

    Environment

    leave empty

    Don't put passwords in the form. After it connects, ask your assistant to add your servers (see below); passwords are typed on a page on your own computer. Some forms want the args one per line instead of separated by spaces. If the client cannot find uvx, use its full path as the Command, as described below.

  • Codex, opencode and others: see AGENTS.md.

--python 3.13 keeps uv off the newest Python (3.15), which some dependencies do not support yet. If the client cannot find uvx, put its full path in command: C:\Users\<you>\.local\bin\uvx.exe on Windows, /Users/<you>/.local/bin/uvx on macOS.

Related MCP server: Redfish MCP Server

Connect your servers

Just ask your assistant, and it guides you in the chat:

  • "Sign in to HPE GreenLake" for Compute Ops Management. If your chat cannot show pop-ups, it gives you a link to a page on your own computer to type your email.

  • "Add my iLO" or "add my OneView", or "import my servers from a file" (.ini or .csv).

Passwords are typed on a page on your own computer, never in the chat.

Update

proliant-mcp@latest picks up new releases whenever your AI client restarts the server. To stay on one version, use proliant-mcp@X.Y.Z. To check what you run: uvx --python 3.13 proliant-mcp@latest --check --connect.

More

Tools | Configuration (inventory file, environment variables, API client) | Advanced (pinning, testing, skills, security) | Changelog

Credentials stay on your computer and are never sent to the AI model. MIT licensed; not an official HPE product.

Available Tools

55 tools
add_serverAdd an iLO or OneView to the inventoryA

Add one iLO or OneView to the inventory with pop-ups: a form (type, address, name, user name), then a secure page for the password. The login is checked before saving and the server is usable at once. Call it when the user wants to add a server or none is configured. Never ask for or pass a password.

Inputs: host, name, type, username. Returns: object

add_servers_startAdd multiple iLO serversA

Add multiple iLOs from an IP range, pasted list, CSV, INI, text file or Excel workbook. Returns a local page link: show it to the user, who selects a file or enters addresses, reviews the list and types credentials there, never in chat. The page checks the selected logins and lets the user choose what to save. Call add_servers_status immediately and keep calling it until saved or failed; do not ask the user to confirm in chat.

Inputs: no named parameters. Returns: object

add_servers_statusAdd Servers StatusA

Wait for the bulk add started by add_servers_start. Returns progress, saved results, or a failure. Keep calling while it is waiting; the browser page guides the user.

Inputs: no named parameters. Returns: object

add_server_startAdd an iLO or OneView without pop-upsA

Add one iLO or OneView without pop-ups, for clients where add_server's pop-ups do not appear. Returns enter_server or enter_password with the url of a secure local page: tell the user to fill it in there (never in chat; never pass a password). Then call add_server_status until saved or failed, without waiting for the user to reply. The login is checked before saving. A new add ends the previous one; previous_add says how it ended: report that, not a guess.

Inputs: host, name, type, username. Returns: object

add_server_statusAdd Server StatusA

Next step of add_server_start. Waits up to 45 seconds for the user, then returns enter_password (again, with the reason, if the password was wrong), saved, or failed. If waiting is true nothing changed yet: remind the user of the step and call it again.

Inputs: no named parameters. Returns: object

clear_inventory_cacheClear Inventory CacheA
DestructiveIdempotent

Remove locally cached hardware snapshots when the user asks. Does not change the cache setting or delete the inventory or credentials.

Inputs: no named parameters. Returns: object

com_api_getCom Api GetA
Read-onlyIdempotent

Raw read-only GET of any Compute Ops Management API resource, for data the other com_ tools don't cover (server inventory, settings, appliances, reports). Secrets are redacted.

Inputs: path (required), account. Returns: object

com_get_overviewCom Get OverviewA
Read-onlyIdempotent

Compute Ops Management fleet report: server count by health, power, connection, generation and model; servers needing attention; disconnected servers; soonest subscription expirations; active (uncleared) alerts by severity with the newest ten.

Inputs: account. Returns: object

com_get_serverCom Get ServerA
Read-onlyIdempotent

One COM server in detail: per-subsystem health, iLO, subscription, last firmware update, firmware inventory, CPU, GPUs, storage controllers and drives, network ports (mode, link, speed, MAC) and active alerts. For several servers use com_list_servers, com_list_gpus or com_list_nics.

Inputs: server (required), account. Returns: object

com_hardware_reportCom Hardware ReportA
Read-onlyIdempotent

Whole-fleet hardware table, compact: servers with identical hardware are grouped into one configuration with their names, model, CPU, storage controllers and drives, GPUs and network adapters (with mode), total_storage_gb, plus NIC mode totals and the servers COM has no data for (unknown, not absent). Use it for "table of each server's storage, GPU and NIC config" and for "how many servers have more than N TB" (storage_over_tb: storage_filter gives the counts).

Inputs: account, connected, name_contains, storage_over_tb. Returns: object

com_list_alertsCom List AlertsB
Read-onlyIdempotent

Newest COM alerts (hardware, security, service events), uncleared only by default.

Inputs: limit, server, account, severity, +1 more. Returns: result

com_list_firmware_bundlesCom List Firmware BundlesB
Read-onlyIdempotent

Firmware bundles (SPPs and patches) available in COM, newest first.

Inputs: account, include_inactive. Returns: result

com_list_gpusCom List GpusA
Read-onlyIdempotent

GPU report for the whole COM fleet: per server the model, iLO firmware, health, CPU and GPUs (name, vendor, part number, count, health), plus totals by GPU model and the servers COM has no inventory for (GPUs unknown, not absent). Start here for any GPU question.

Inputs: account, connected, name_contains, include_servers_without_gpus. Returns: object

com_list_groupsCom List GroupsC
Read-onlyIdempotent

COM server groups: members (serials), compliance (firmware, iLO settings) and whether firmware is updated automatically when a server is added.

Inputs: account. Returns: result

com_list_jobsCom List JobsB
Read-onlyIdempotent

Newest COM jobs (firmware updates, inventory collection, power, OneView sync, ...) with state and result.

Inputs: limit, state, account. Returns: result

com_list_nicsCom List NicsA
Read-onlyIdempotent

Network adapter report for the whole COM fleet: per server each NIC/HBA (mode Ethernet / InfiniBand / FibreChannel, ports, ports up, link speeds, firmware, health), plus totals by mode, adapter model and link speed, and the servers COM has no network data for. Start here for any NIC, HBA, link speed or network mode question.

Inputs: account, connected, linked_only, name_contains. Returns: object

com_list_serversCom List ServersA
Read-onlyIdempotent

Servers in Compute Ops Management as JSON: name, serial, model, generation, health, power, COM connection, subscription, iLO host/IP/version, OS, CPU vendor, firmware bundle. One call returns the whole fleet; use it to analyze or compare. To just SHOW the list, prefer com_list_servers_table (ready-made table, exact counts, much faster).

Inputs: health, account, connected, name_contains, +1 more. Returns: result

com_list_servers_tableCom List Servers TableA
Read-onlyIdempotent

The COM servers as a ready-made Markdown table with exact counts, for when the user wants to SEE the list ("list my servers", "which are critical"). Show table as written and quote counts (total, by health, power, model, connected): do not recount or retype the data into a script. Same filters as com_list_servers, which returns the full JSON for analysis.

Inputs: health, account, columns, connected, +1 more. Returns: object

com_loginSign in to HPE GreenLakeA

Sign the user in to HPE GreenLake so the com_ tools work, with pop-ups: email, then an Okta Verify number (@hpe.com) or a secure password page (other accounts). Creates a GreenLake API client and saves it on this computer. Call it when a com_ tool says no COM account is configured or login failed, or when asked to sign in. Never ask for the password in chat.

Inputs: email, region, workspace. Returns: object

com_login_startCom Login StartA

Sign in to HPE GreenLake without pop-ups, for clients where com_login's pop-ups do not appear. Returns the step to relay in the chat: enter_email (url of a local page; skipped if you passed an email), approve_push (the number to tap in Okta Verify) or enter_password (url of a secure page; never ask for the password in chat). Then call com_login_status until signed_in or failed, without waiting for the user to reply.

Inputs: email, region, workspace. Returns: object

com_login_statusCom Login StatusA

Next step of com_login_start: waits up to 45 s for the user, returns approve_push, enter_password, choose_workspace (with workspaces), signed_in (with the server count) or failed. If waiting is true, remind the user of the step and call again.

Inputs: workspace. Returns: object

find_serverFind ServerA
Read-onlyIdempotent

Which server is this? Looks up a name, iLO IP/hostname, serial or OS hostname in the iLO inventory, every COM account and every OneView appliance in one call. If nothing matches and the query is an address, it reads that iLO's login-free identity pages (iLO model, firmware, server model, serial). Use it instead of searching the list tools by hand.

Inputs: query (required), probe. Returns: object

get_com_inventory_snapshotGet Com Inventory SnapshotA

COM hardware inventory across the fleet, from the local cache or live; each server says which and when. COM's own inventory may be older. refresh=true bypasses the local cache, not COM's collection. Not for current health, power or alerts: use the live COM tools.

Inputs: account, refresh, name_contains. Returns: object

get_event_logGet Event LogA
Read-onlyIdempotent

Newest entries from the IML, iLO event log or Security Log, filtered by severity, time and text; with summary, identical messages are grouped (compact; use it for "what happened"). Entries with a wrong iLO clock are marked time_invalid, listed last, and left out when since/until is set. For several servers use get_fleet_event_summary; for logins use get_ilo_logins.

Inputs: server (required), log, limit, since, +5 more. Returns: result

get_firmware_inventoryGet Firmware InventoryC
Read-onlyIdempotent

All firmware components and versions (iLO, BIOS/System ROM, NICs, storage controllers, drives, CPLD, ...).

Inputs: server (required). Returns: result

get_fleet_event_summaryGet Fleet Event SummaryA
Read-onlyIdempotent

Significant events for many servers in one call: per server, the IML, iLO event log or Security Log grouped by message (count, first/last time, repaired), Warning and Critical by default, most severe first. Use it for "errors on these servers". Unreachable iLOs return an error.

Inputs: log, limit, since, until, +3 more. Returns: object

get_fleet_summaryGet Fleet SummaryA
Read-onlyIdempotent

get_server_summary (including the OS and boot state) for every configured server at once. Unreachable servers are returned with an error field instead of failing the whole call.

Inputs: no named parameters. Returns: result

get_healthGet HealthA
Read-onlyIdempotent

Overall and per-subsystem health (processors, memory, storage, network, fans, power supplies, temperatures) plus fan / power-supply redundancy.

Inputs: server (required). Returns: object

get_ilo_infoGet Ilo InfoB
Read-onlyIdempotent

iLO details: model (iLO 5/6/7), firmware version and date, license, Compute Ops Management connection status, and the iLO's own network (hostname, IP, MAC, DHCP).

Inputs: server (required). Returns: object

get_ilo_loginsGet Ilo LoginsA
Read-onlyIdempotent

Who logged in to the iLOs, from each iLO Event Log, for many servers in one call: logins per day, by type, user and source IP/host, failed logins and lockout alerts. Says when a log does not reach back to the window start (counts are then a minimum). proliant-mcp's own sessions show as Browser logins and are counted only in this_computer_logins unless include_this_computer. Unreachable iLOs return an error.

Inputs: days, servers, utc_offset_hours, include_this_computer. Returns: object

get_inventory_cache_statusGet Inventory Cache StatusA
Read-onlyIdempotent

Whether local hardware snapshot caching is enabled (it is on by default) and its lifetime. It does not inspect credentials or create a cache.

Inputs: no named parameters. Returns: object

get_inventory_snapshotGet Inventory SnapshotA

Hardware snapshots (processors, memory, firmware) for one or more iLOs, from the local cache (on by default, 15 minutes) or live; each says which and when it was collected. refresh=true forces a live read. The iLO login is checked even on a hit. Not for current health or power: use the live tools.

Inputs: refresh, servers, categories. Returns: object

get_memoryGet MemoryA
Read-onlyIdempotent

Memory: total GiB, populated/empty slot counts, and each DIMM (slot, size, type, speed, vendor, HPE part number, health).

Inputs: server (required). Returns: object

get_network_adaptersGet Network AdaptersB
Read-onlyIdempotent

Host network adapters: model, part number, slot, firmware, and ports (MAC, link, speed, LLDP neighbor switch/port when available).

Inputs: server (required). Returns: result

get_processorsGet ProcessorsB
Read-onlyIdempotent

CPUs (socket, model, cores, threads, speed) and GPUs that iLO reports.

Inputs: server (required). Returns: object

get_server_summaryGet Server SummaryB
Read-onlyIdempotent

Server identity and state: model, product ID, serial, power and POST state, health, UID light, BIOS and iLO versions, CPU count/model, total memory, and os: whether an OS is running and which (name and version when the HPE agent reports it), boot progress (e.g. stuck in POST or BIOS setup) and the UEFI boot order.

Inputs: server (required). Returns: object

get_storageGet StorageB
Read-onlyIdempotent

Storage subsystems: controllers (model, firmware), physical drives (model, media, capacity, serial, firmware, bay) and logical volumes / RAID.

Inputs: server (required). Returns: result

greenlake_api_clients_statusGreenlake Api Clients StatusA
Read-onlyIdempotent

Next step of greenlake_list_api_clients_start or greenlake_delete_api_clients_start: waits up to 45 s for the user, returns the step (approve_push, enter_password, choose_workspace, select_api_clients, confirm_deletion) or the result (listed, deleted, cancelled, failed). If waiting is true, remind the user and call again. Changes nothing itself.

Inputs: workspace. Returns: object

greenlake_delete_api_clients_startDelete GreenLake API clientsA
Destructive

Delete personal HPE GreenLake API clients that the USER selects, e.g. after hitting the limit. Signs in like com_login_start, then a local page lists the clients with check boxes; the user ticks, reviews and confirms there. You cannot choose or confirm for them. Deletion is permanent and stops anything using those clients. Relay each step, then call greenlake_api_clients_status until deleted, cancelled or failed.

Inputs: email, preselect, workspace. Returns: object

greenlake_list_api_clients_startGreenlake List Api Clients StartA

List the user's own personal HPE GreenLake API clients (name, client ID, created, and whether this computer's saved login uses it), e.g. when they hit the limit. Signs in like com_login_start; changes nothing and shows no secrets. Relay each step, then call greenlake_api_clients_status until listed.

Inputs: email, workspace. Returns: object

greenlake_list_servicesGreenlake List ServicesA
Read-onlyIdempotent

Every HPE GreenLake service in the catalog and where each is provisioned in the user's workspace (Compute Ops Management, Data Services, Aruba Central, ...): name, provisioned or not, regions with status, description, plus the counts. Use it for "what services do I have in GreenLake" and "is X available / set up". Uses the same sign-in as the com_ tools.

Inputs: account, provisioned_only. Returns: object

import_inventoryImport servers from a fileA

Import many iLO and OneView entries from a .ini or .csv file (Excel: save as CSV) with pop-ups in the chat: the user types the file's path, confirms what was found, and gives one shared password on a secure page for entries that have none. Optionally checks each login. The tools use the entries immediately. Takes no arguments: the user chooses the file, not you.

Inputs: no named parameters. Returns: object

list_serversList ServersA
Read-onlyIdempotent

[proliant-mcp 0.18.0] List what this server can reach: iLO servers (name, iLO host), OneView appliances and COM accounts (name, region), plus the running proliant-mcp version and whether a newer release exists. Credentials are never returned. Call this first, and for "which version".

Inputs: no named parameters. Returns: object

oneview_get_applianceOneview Get ApplianceB
Read-onlyIdempotent

OneView appliance report: model and software version, appliance CPU/memory/disk health, counts of server hardware, profiles, enclosures and interconnects, server hardware by status and power, and active alerts by severity.

Inputs: appliance. Returns: object

oneview_get_server_hardwareOneview Get Server HardwareA
Read-onlyIdempotent

One OneView server in detail: the list fields plus UID light, every firmware component with location and version, and its active alerts.

Inputs: server (required), appliance. Returns: object

oneview_list_alertsOneview List AlertsB
Read-onlyIdempotent

Newest OneView alerts with the affected resource, description and corrective action.

Inputs: limit, severity, appliance, active_only. Returns: result

oneview_list_enclosuresOneview List EnclosuresC
Read-onlyIdempotent

Synergy frames / enclosures: model, serial, status, firmware baseline, populated bays, Composer modules, power capacity and allocation, PSU status and failed fans.

Inputs: appliance. Returns: result

oneview_list_firmware_baselinesOneview List Firmware BaselinesB
Read-onlyIdempotent

Firmware baselines (SPP / Synergy Service Packs) uploaded to OneView, newest first.

Inputs: appliance. Returns: result

oneview_list_interconnectsOneview List InterconnectsA
Read-onlyIdempotent

Interconnect modules (Virtual Connect, switches): model, firmware, status, power, enclosure, hostname and IP. For uplink and port status use oneview_list_uplink_sets.

Inputs: appliance. Returns: result

oneview_list_server_hardwareOneview List Server HardwareC
Read-onlyIdempotent

Servers managed by OneView: name, OS hostname, model, serial, status, power, assigned profile, enclosure/bay, CPU, memory, ROM, OS and iLO (model, firmware, IP).

Inputs: appliance. Returns: result

oneview_list_server_profilesOneview List Server ProfilesC
Read-onlyIdempotent

Server profiles: status, assigned server hardware, template and compliance, firmware baseline, boot mode and connection count.

Inputs: appliance. Returns: result

oneview_rest_getOneview Rest GetA
Read-onlyIdempotent

Raw read-only GET of any OneView REST resource, for data the other oneview_ tools don't cover (networks, uplink sets, logical enclosures, tasks, utilization). Secrets are redacted.

Inputs: path (required), appliance. Returns: object

redfish_getRedfish GetA
Read-onlyIdempotent

Raw read-only GET of any iLO Redfish resource, for data the other tools don't cover.

Inputs: path (required), server (required). Returns: object

set_inventory_cacheSet Inventory CacheA
Idempotent

Turn the local hardware snapshot cache on or off, or change its lifetime, when the user asks. It is on by default and stored on this computer in an owner-only folder (server names and serial numbers, never passwords). Turning it off keeps the existing data; clear_inventory_cache removes it. Live tools are unaffected.

Inputs: enabled (required), ttl_seconds. Returns: object

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections.

Loading tool schema changelog…

    TDQS

    B3.4/5.0

    Scored across 55 tools

    Disambiguation4/5

    Purpose families are cleanly separated by backend (local iLO get_*/list_*, com_* for Compute Ops Management, oneview_* for OneView, greenlake_* for auth), and descriptions explicitly cross-reference each other ("use get_fleet_event_summary for several servers"). Real overlap remains in the parallel flows: com_login vs com_login_start, add_server vs add_server_start vs add_servers_start vs import_inventory, and com_list_servers vs com_list_servers_table, all of which an agent could plausibly misselect despite the guidance. Overall mostly distinct with a handful of confusable near-duplicates.

    Naming Consistency4/5

    Everything is snake_case with a consistent verb_noun shape, and subsystem prefixes (com_, oneview_, greenlake_) form a coherent namespace. Minor deviations: some names lead with the subsystem noun (com_list_servers, oneview_get_appliance) rather than verb-first like get_health, and irregular verbs appear (find_server, redfish_get, com_api_get). Still highly readable and predictable.

    Tool Count3/5

    55 tools is heavy, though covering three distinct management platforms (iLO, OneView, GreenLake COM) justifies breadth. A meaningful share of the count is onboarding/auth scaffolding duplicated across pop-up and non-pop-up variants (add_server, add_server_start, add_server_status, add_servers_start, add_servers_status, import_inventory, com_login, com_login_start, com_login_status, plus two greenlake_*_start tools), which inflates the surface. Borderline-heavy rather than well-scoped.

    Completeness3/5

    Read/monitoring coverage is excellent: health, firmware, memory, storage, network, events, alerts, jobs, groups, uplinks, and raw escape hatches (redfish_get, com_api_get, oneview_rest_get) that let an agent fetch anything else. But the surface is almost entirely read-only: no server removal from inventory, no iLO power actions (on/off/reset), and no write path for firmware updates or BIOS settings, which are core lifecycle operations for this domain. These are notable gaps, partially workable around only by out-of-band means since the raw tools are documented as read-only GETs.

    Maintenance

    ActivityMaintained
    ResponsivenessOutdated data

    Related MCP Connectors

    Related MCP Servers