Skip to main content
Glama
Replaced by its MCP Registry listing

This endpoint is listed in the official MCP Registry as middle.network - DNS, Email, Network, Compliance, Domain and Audit Tools. If you published it, claim ownership there.

MAC vendor lookup

mac_vendor
Read-onlyIdempotent

Look up a MAC address or 6-hex OUI prefix offline against the bundled IEEE OUI (MA-L/MA-M/MA-S) registry with unicast/multicast/LAA flags. text strips non-hex separators (:, -, .) and requires exactly 6 hex digits (OUI) or 12 hex digits (full MAC). Use to identify NIC manufacturers, not derive IPv6 EUI-64 addresses (mac_ipv6). Runs locally; randomized (LAA) and multicast MACs return info findings with vendor=null, and invalid lengths return isError=true. Requires middle.network auth; uses 1 daily quota unit.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "text": "<text>"
    },
    "name": "mac_vendor"
  }
}

Input Schema

NameRequiredDescriptionDefault
textYesA MAC address or its first 6 hex digits.

Output Schema

NameRequiredDescriptionDefault
atNoISO-8601 UTC timestamp when the result was generated.
msNoElapsed execution time in milliseconds.
dataYesTool-specific structured payload (records, timings, parsed fields, or scores).
toolYesCatalog tool identifier.
shareNoOptional shareable report link metadata.
statusYesOverall diagnostic verdict (worst finding wins; no findings = pass).
targetYesNormalised domain, IP, or input target.
limitedNoOptional list of upstream data sources that were rate-limited or unavailable.
summaryYesPlain-English and technical one-line summaries.
findingsYesOrdered diagnostic findings with severity and actionable fixes.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Changed8 schema fields changed
    • addedOutput schema / properties / at
      Added value: +{
      +  "description": "ISO-8601 UTC timestamp when the result was generated.",
      +  "type": "string"
      +}
    • changedOutput schema / properties / findings / items / properties / level / enum
      Previous value: -[
      -  "ok",
      -  "info",
      -  "warn",
      -  "fail",
      -  "error"
      -]New value: +[
      +  "pass",
      +  "info",
      +  "warn",
      +  "fail",
      +  "error"
      +]
    • addedOutput schema / properties / findings / items / required
      Added value: +[
      +  "level",
      +  "plain",
      +  "tech"
      +]
    • addedOutput schema / properties / ms
      Added value: +{
      +  "description": "Elapsed execution time in milliseconds.",
      +  "type": "integer"
      +}
    • changedOutput schema / properties / status / description
      Previous value: -"Overall diagnostic verdict."New value: +"Overall diagnostic verdict (worst finding wins; no findings = pass)."
    • changedOutput schema / properties / status / enum
      Previous value: -[
      -  "ok",
      -  "warn",
      -  "fail",
      -  "error",
      -  "info"
      -]New value: +[
      +  "pass",
      +  "warn",
      +  "fail",
      +  "error",
      +  "info"
      +]
    • addedOutput schema / properties / summary / required
      Added value: +[
      +  "plain",
      +  "tech"
      +]
    • addedOutput schema / required
      Added value: +[
      +  "tool",
      +  "target",
      +  "status",
      +  "summary",
      +  "findings",
      +  "data"
      +]
  2. Changed1 schema field changed
    • changedOutput schema / (root)
      Previous value: -nullNew value: +{
      +  "description": "Standard middle.network ToolResult envelope returned in structuredContent.",
      +  "properties": {
      +    "data": {
      +      "description": "Tool-specific structured payload (records, timings, parsed fields, or scores).",
      +      "type": "object"
      +    },
      +    "findings": {
      +      "description": "Ordered diagnostic findings with severity and actionable fixes.",
      +      "items": {
      +        "properties": {
      +          "fix": {
      +            "description": "Optional copy-paste fix or next step.",
      +            "type": "string"
      +          },
      +          "level": {
      +            "description": "Finding severity.",
      +            "enum": [
      +              "ok",
      +              "info",
      +              "warn",
      +              "fail",
      +              "error"
      +            ],
      +            "type": "string"
      +          },
      +          "plain": {
      +            "description": "Plain-English explanation.",
      +            "type": "string"
      +          },
      +          "tech": {
      +            "description": "Technical evidence or record value.",
      +            "type": "string"
      +          }
      +        },
      +        "type": "object"
      +      },
      +      "type": "array"
      +    },
      +    "limited": {
      +      "description": "Optional list of upstream data sources that were rate-limited or unavailable.",
      +      "items": {
      +        "properties": {
      +          "reason": {
      +            "description": "Why the upstream result was limited.",
      +            "type": "string"
      +          },
      +          "upstream": {
      +            "description": "Upstream provider name.",
      +            "type": "string"
      +          }
      +        },
      +        "type": "object"
      +      },
      +      "type": "array"
      +    },
      +    "share": {
      +      "description": "Optional shareable report link metadata.",
      +      "properties": {
      +        "at": {
      +          "description": "ISO-8601 timestamp when the share snapshot was created.",
      +          "type": "string"
      +        },
      +        "id": {
      +          "description": "Share identifier at https://share.middle.network/<id>.",
      +          "type": "string"
      +        }
      +      },
      +      "type": "object"
      +    },
      +    "status": {
      +      "description": "Overall diagnostic verdict.",
      +      "enum": [
      +        "ok",
      +        "warn",
      +        "fail",
      +        "error",
      +        "info"
      +      ],
      +      "type": "string"
      +    },
      +    "summary": {
      +      "description": "Plain-English and technical one-line summaries.",
      +      "properties": {
      +        "plain": {
      +          "description": "Plain-English summary for end users.",
      +          "type": "string"
      +        },
      +        "tech": {
      +          "description": "Exact technical summary for engineers.",
      +          "type": "string"
      +        }
      +      },
      +      "type": "object"
      +    },
      +    "target": {
      +      "description": "Normalised domain, IP, or input target.",
      +      "type": "string"
      +    },
      +    "tool": {
      +      "description": "Catalog tool identifier.",
      +      "type": "string"
      +    }
      +  },
      +  "type": "object"
      +}
  3. First observed

TDQS

A4.8/5.0
Behavior5/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare readOnly/openWorld=false/idempotent/non-destructive, but the description goes further: it discloses offline/local execution, the separator-stripping normalization, the exact length requirements, that randomized (LAA) and multicast inputs return info findings with vendor=null, that invalid lengths yield isError=true, plus the auth requirement and 1-unit daily quota cost.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Four sentences, front-loaded with purpose before format rules and edge-case behavior; the auth/quota sentence sits last where operational cost belongs. It is dense but nothing is redundant, though the parenthetical registry acronyms (MA-L/MA-M/MA-S) add little for an agent.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness5/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a single-parameter lookup with an output schema present, the description covers purpose, alternatives, input format, failure modes, and operational cost. Return-value shape is left to the output schema, which is the correct division of labor.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 100%, so the baseline is 3, but the description adds real validation semantics the schema lacks: non-hex separators (:, -, .) are stripped and exactly 6 or 12 hex digits are required. That tells the agent which inputs will fail, though it does not explain the 64-character maxLength interaction.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description opens with a specific verb and resource: 'Look up a MAC address or 6-hex OUI prefix offline against the bundled IEEE OUI (MA-L/MA-M/MA-S) registry.' It even names the registry variants and flags, so the agent knows exactly what class of data is consulted, and it explicitly contrasts itself with the mac_ipv6 sibling.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines5/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

'Use to identify NIC manufacturers, not derive IPv6 EUI-64 addresses (mac_ipv6)' gives both a positive use case and a named exclusion with the alternative tool. This is exactly the routing signal an agent needs when mac_ipv6 sits in the sibling list.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.

Resources