EU MDR Article 87 Vigilance Incident Reporting Statutory Deadlines Calculator

mdr_vigilance_reporting_timeline_calculator
Read-onlyIdempotent

[EU MDR Article 87 vigilance incident reporting statutory deadlines calculator. Pure calculation, read-only, side-effect free]. Calculates strict statutory notification deadlines under Regulation (EU) 2017/745 Article 87 (public health threat: 2 days; death/deterioration: 10 days; serious incidents: 15 days) and prepares initial MIR vigilance report payloads. Usage: Pass incident awareness date and severity classification to compute exact deadline dates and EUDAMED notification requirements. Returns: JSON object with { incidentReferenceId: string, incidentSeverityType: string, statutoryDeadlineDays: number, dateOfIncidentAwarenessIso: string, statutoryDeadlineDateIso: string, isImmediateNotificationMandatory: boolean, eudamedReportingFormType: string, initialReportRequiredContent: object }.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "incidentReferenceId": "<incidentReferenceId>",
      "deviceName": "<deviceName>",
      "manufacturerName": "<manufacturerName>",
      "dateOfIncidentAwarenessIso": "<dateOfIncidentAwarenessIso>",
      "incidentSeverityType": "<incidentSeverityType>",
      "isDeviceCausalRelationshipEstablishedOrSuspected": "<isDeviceCausalRelationshipEstablishedOrSuspected>",
      "isFieldSafetyCorrectiveActionPlanned": "<isFieldSafetyCorrectiveActionPlanned>",
      "reportingToMemberStateCompetentAuthorityIso2": "<reportingToMemberStateCompetentAuthorityIso2>"
    },
    "name": "mdr_vigilance_reporting_timeline_calculator"
  }
}

Input Schema

NameRequiredDescriptionDefault
deviceNameYesCommercial name and model of the medical device involved
manufacturerNameYesLegal name of the manufacturer or EU Authorized Representative
incidentReferenceIdYesInternal complaint or vigilance file reference identifier
incidentSeverityTypeYesIncident severity category ex MDR Article 87(3)-(5)
dateOfIncidentAwarenessIsoYesDate when manufacturer first became aware of the incident (YYYY-MM-DD)
isFieldSafetyCorrectiveActionPlannedYesWhether a Field Safety Corrective Action (FSCA) and Field Safety Notice (FSN) are being initiated (Art. 87(8))
reportingToMemberStateCompetentAuthorityIso2Yes2-letter ISO country code of national competent authority receiving notification
isDeviceCausalRelationshipEstablishedOrSuspectedYesWhether a causal link between device and incident is established or reasonably possible

Schema Changelog

Changes observed during successful MCP inspections.

  1. Added

TDQS

A3.8/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already establish read-only, idempotent, non-destructive behavior, so the description's main added value is the statutory deadline mapping by severity and the note that it prepares report payloads rather than submitting them. It does not cover edge cases such as weekend/holiday handling or how all inputs affect the result.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The description is front-loaded and organized into purpose, usage, and return sections, which makes it easy to scan. The bracketed header repeats the title and annotations somewhat redundantly, and the return-field list is long, but it earns its place because no output schema is supplied.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

The description supplies a return-object shape and deadline logic that compensate for the absence of an output schema. It is slightly incomplete for the tool's complexity because the enum includes TREND_REPORTABLE_INCIDENT but the listed deadline categories do not cover it, and several required inputs are not behaviorally explained.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 100%, so parameter descriptions already carry the baseline. The description adds useful meaning by mapping severity categories to statutory deadline windows and naming the awareness date and severity classification as the key inputs, though it does not explain how FSCA, causal relationship, or member-state authority inputs influence output.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description gives a specific verb and resource: it calculates EU MDR Article 87 statutory notification deadlines and prepares initial MIR vigilance report payloads. The scope is clear, but it does not explicitly differentiate this calculator from adjacent MDR tools such as incident_severity_triage.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

The 'Usage' sentence tells the agent to pass incident awareness date and severity classification, which implies when the tool is applicable. However, it gives no explicit when-to-use versus alternatives guidance and no exclusions or prerequisites.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.