Skip to main content
Glama

getecoback-raumklima

stromlog_integrationsmethode_abstand

Read-only

Aus drei Leistungswerten zwei ausdrücklich angenommene Integrationsarten vergleichen — Test sensitivity to step-hold versus linear interpretation of three unevenly spaced power samples.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "anfang_w": "<anfang_w>",
      "mitte_w": "<mitte_w>",
      "ende_w": "<ende_w>",
      "erster_abschnitt_min": "<erster_abschnitt_min>",
      "zweiter_abschnitt_min": "<zweiter_abschnitt_min>"
    },
    "name": "stromlog_integrationsmethode_abstand"
  }
}

Input Schema

NameRequiredDescriptionDefault
ende_wYesWirkleistung am letzten abgelesenen Punkt in Watt.
mitte_wYesWirkleistung am mittleren abgelesenen Punkt in Watt.
anfang_wYesWirkleistung am ersten abgelesenen Punkt in Watt.
erster_abschnitt_minYesMinuten vom ersten zum zweiten Punkt.
zweiter_abschnitt_minYesMinuten vom zweiten zum dritten Punkt.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Added

TDQS

B3.4/5.0
Behavior3/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

The readOnlyHint/openWorldHint=false annotations already establish that this is a pure, side-effect-free computation, and the description is consistent with that. It adds a little context by framing the result as a sensitivity test between two conventions, but says nothing about what is returned (a delta, two values, a percentage) or about the units of the comparison.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Two compact clauses with no filler; the operation comes first and the interpretation follows. The German phrasing is dense and jargon-heavy ('ausdrücklich angenommene Integrationsarten'), which slightly slows parsing but costs no length.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

All inputs are fully specified via the schema and the tool is read-only, so the call itself is safe to make. However, with no output schema, the description should say what the comparison yields (difference in watt-hours? two totals?), and it leaves that entirely unspecified.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 100%, so the five parameters and their ranges are already fully documented in the schema. The description reinforces that the three watt values are unevenly spaced samples, but it never explicitly ties the two segment-duration parameters to the step-hold/linear split, so it adds no meaning beyond the schema.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names a concrete operation (comparing two assumed integration methods) over a concrete input (three unevenly spaced power samples), so an agent knows this is a numerical comparison, not a lookup or mutation. It does not distinguish itself from any sibling, and the phrase 'zwei ausdrücklich angenommene Integrationsarten' is abstract until the second clause names step-hold vs. linear.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Usage is only implied: 'Test sensitivity' hints that this is for checking how much the energy estimate depends on the integration convention. There is no explicit when-to-use, no when-not-to-use, and no pointer to an alternative tool for plain energy totals or for other sample spacings.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.

Resources