Kennzeichne, welche Beobachtungen sicher in die stromlose Phase fallen — Classify door and temperature evidence inside the confirmed outage window

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "aus_sicher_ab_min": "<aus_sicher_ab_min>",
      "aus_sicher_bis_min": "<aus_sicher_bis_min>",
      "tuer_min": "<tuer_min>",
      "temperatur_min": "<temperatur_min>",
      "tuer_erfasst": "<tuer_erfasst>",
      "fach_temp_erfasst": "<fach_temp_erfasst>"
    },
    "name": "gefrierschrank_stoerakte_tuer_und_temperaturzeitpunkt"
  }
}

Input Schema

NameRequiredDescriptionDefault
tuer_minYesZeitpunkt der ersten dokumentierten Öffnung, falls beobachtet
tuer_erfasstYesTüröffnung tatsächlich mit Zeitstempel beobachtet
temperatur_minYesZeitpunkt der letzten direkt erfassten Fachtemperatur, falls beobachtet
aus_sicher_ab_minYesBeginn der direkt bestätigten stromlosen Teilphase
fach_temp_erfasstYesFachtemperatur mit Zeitstempel und eindeutigem Messort beobachtet
aus_sicher_bis_minYesEnde derselben direkt bestätigten Teilphase

Schema Changelog

Changes observed during successful MCP inspections.

  1. Added

TDQS

B3.4/5.0
Behavior3/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare readOnlyHint=true and openWorldHint=false, so safety is covered; the description adds that this is a classification/judgment step rather than a computation. However, it does not disclose what happens to observations that fall outside the window (dropped, flagged, returned as unsafe), nor the shape of the classification result — significant omissions for a tool whose entire output is a judgment.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

A single front-loaded sentence with the classifying verb first, followed by the bilingual gloss, with no filler. The German/English duplication is slightly redundant, but it is defensible for a German-named tool consumed by a non-German model.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a six-parameter, all-required classifier with no output schema, the definition does not say what the returned classification looks like or how ambiguous cases (door observed but not timestamped, temperature unrecorded) are resolved. Since no output schema exists to carry that burden, the description should do more than restate the goal.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

With schema description coverage at 100%, every parameter including the two observation flags (tuer_erfasst, fach_temp_erfasst) is already documented in the schema, so baseline 3 applies. The description adds no meaning beyond the schema — notably it never explains how the 'erfasst' booleans interact with the timestamps, which is the semantically delicate part of the call.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description pairs a concrete verb ('Kennzeichne' / 'Classify') with a defined resource and scope: door and temperature evidence inside the confirmed outage window. That is more specific than the opaque tool name and tells an agent what the operation produces. It stops short of naming the sibling it differs from (e.g. gefrierschrank_stromausfall_dauer_zwischen_ankern), so the boundary with related freezer tools is left implicit.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Use is only implied through the phrase 'in die stromlose Phase' / 'inside the confirmed outage window', which suggests the tool is appropriate once an outage window has already been confirmed and timestamped observations exist. There is no explicit when-not guidance, no stated precondition that the window anchors must first be established via another tool, and no pointer to alternatives such as the outage-duration sibling.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser