Magnetic flux density unit converter

bpj_units_flux_density
Read-onlyIdempotent

Convert magnetic flux density from field probes. Enter one of T, mT, uT, nT, G to return the equivalent value in every listed unit.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "value": "<value>",
      "unit": "<unit>"
    },
    "name": "bpj_units_flux_density"
  }
}

Input Schema

NameRequiredDescriptionDefault
unitYes
valueYes

Schema Changelog

Changes observed during successful MCP inspections.

  1. Added

TDQS

A3.9/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare readOnlyHint, idempotentHint, destructiveHint=false and openWorldHint=false, so safety is covered. The description adds real value beyond that by stating the return behavior — the equivalent value in every listed unit — which matters because there is no output schema.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness5/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Two sentences, both earning their place: the first establishes the domain, the second tells the agent what input to supply and what comes back. Constrained input is listed up front with no filler.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a two-parameter pure converter with strong read-only annotations, the definition covers input units and output shape. A note on full unit names (G = gauss) or the response structure would close the last gap, but nothing needed to call it correctly is missing.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 0% and the unit parameter has no enum, so the description carries the burden by enumerating the accepted units (T, mT, uT, nT, G) — a genuine addition the schema lacks. It adds nothing about the value parameter, but the schema already supplies its numeric bounds and title, so the key gap is covered.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names a specific verb and resource ('Convert magnetic flux density') and enumerates the recognized units, so an agent can distinguish it from the many other bpj_units_* converters. It does not, however, address the one genuinely confusable sibling, bpj_units_magnetic_flux, so the differentiation is implicit rather than stated.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

'from field probes' gives a hint of intended context, but there is no explicit when-to-use or when-not-to-use guidance and no named alternative. Usage is implied by the unit list rather than stated.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.