changedInput schema / properties / copper_weight_oz / description
Previous value: -"Finished copper weight in ounces per square foot (oz/ft^2), where 1.0 oz equals 0.0348 mm (35 um). Typical values: 0.5, 1.0, or 2.0."New value: +"Finished copper weight in oz/ft^2 (1.0 oz = 35 um)."
changedInput schema / properties / copper_weight_oz / examples
Previous value: -[
- 1,
- 2
-]New value: +[
+ 1
+]
changedInput schema / properties / current_amps / description
Previous value: -"Target continuous DC current in Amperes (A) for IPC-2152 thermal sizing context. Example: 1.5."New value: +"Target continuous DC current in Amperes for IPC-2152 sizing."
changedInput schema / properties / current_amps / examples
Previous value: -[
- 1,
- 1.5
-]New value: +[
+ 1
+]
changedInput schema / properties / dielectric_height_mm / description
Previous value: -"Dielectric separation H in millimeters (mm) between the signal layer and nearest solid reference plane (>= 0.02 mm). Example: 0.19 for 7628 prepreg."New value: +"Dielectric height H in millimeters to nearest reference plane."
changedInput schema / properties / dielectric_height_mm / examples
Previous value: -[
- 0.19,
- 0.2
-]New value: +[
+ 0.19
+]
changedInput schema / properties / er / description
Previous value: -"Relative dielectric constant (Dk / Er) of the PCB laminate or prepreg at operating frequency (>= 1.0). Example: 4.29 for FR-4 prepreg, 3.48 for Rogers RO4350B."New value: +"Substrate relative dielectric constant Er / Dk (>= 1.0)."
changedInput schema / properties / er / examples
Previous value: -[
- 4.29,
- 4.4
-]New value: +[
+ 4.29
+]
changedInput schema / properties / max_temp_rise_c / description
Previous value: -"Maximum allowable conductor temperature rise above ambient in degrees Celsius (deg C) per IPC-2152. Example: 10.0 or 20.0."New value: +"Maximum allowed conductor temperature rise in degrees Celsius (IPC-2152)."
changedInput schema / properties / max_temp_rise_c / examples
Previous value: -[
- 10,
- 20
-]New value: +[
+ 10
+]
changedInput schema / properties / mode / description
Previous value: -"Transmission line geometry: 'microstrip' for outer layers (F.Cu/B.Cu over reference plane) or 'stripline' for inner layers sandwiched between two reference planes."New value: +"Transmission line geometry: outer microstrip or inner stripline."
changedInput schema / properties / mode / examples
Previous value: -[
- "microstrip",
- "stripline"
-]New value: +[
+ "microstrip"
+]
changedInput schema / properties / trace_spacing_mm / description
Previous value: -"Edge-to-edge copper spacing S in millimeters (mm) between coupled differential pair traces, clamped to >= 0.02 mm. Example: 0.15."New value: +"Edge-to-edge differential pair spacing S in millimeters (>= 0.02)."
changedInput schema / properties / trace_spacing_mm / examples
Previous value: -[
- 0.15,
- 0.2
-]New value: +[
+ 0.15
+]
changedInput schema / properties / trace_width_mm / description
Previous value: -"Copper trace width W in millimeters (mm), clamped to >= 0.02 mm. Example: 0.25 for 50-Ohm microstrip on 4-layer FR-4."New value: +"Copper trace width W in millimeters (>= 0.02 mm)."
changedInput schema / properties / trace_width_mm / examples
Previous value: -[
- 0.15,
- 0.25
-]New value: +[
+ 0.25
+]