Tankless Water Heater Size Calculator (GPM, Temperature Rise, BTU & kW)
calc_tankless_water_heater_sizeSize a tankless water heater from your peak hot-water flow and the rise from winter inlet temperature to your setpoint: required Btu/h, gas input, electric kW and amps. Formula: Temperature rise = setpoint − inlet. Heat output (Btu/h) = gpm × 8.34 lb/gal × 60 min × rise. Gas input = output ÷ efficiency. Electric kW = output ÷ 3,412.14; amps = kW × 1,000 ÷ volts.
Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| volts | No | Electric supply voltage (V); default 240 | |
| inlet_f | No | Coldest incoming water temperature (winter) (°F); default 52 | |
| outlet_f | No | Hot water setpoint (°F); default 120 | |
| peak_gpm | No | Peak hot-water flow (fixtures used at the same time) (gpm); default 4.5 | |
| gas_efficiency_pct | No | Gas unit efficiency (spec sheet) (%); default 82 |