Generator Size Calculator (Running & Starting Watts for Your House)
calc_generator_sizeWhat size generator you need for a power outage: add the running watts of everything you will run at once, then add the single biggest motor starting surge. Enter how many of each item you plan to run at the same time. Formula: Total running watts = Σ (quantity × running watts). Total starting watts = total running watts + the single highest additional starting watts among the items you run, because motors rarely start at the same instant. Amps at 240 V = running watts ÷ 240. Margin is an optional buffer you choose.
Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| box_fan | No | Box fan, 20 in: how many (200 W running); default 0 | |
| light_60w | No | Light bulb, 60 W: how many (60 W running); default 4 | |
| margin_pct | No | Safety margin (your choice) (%); default 10 | |
| coffee_maker | No | Coffee maker: how many (1,000 W running); default 0 | |
| refrigerator | No | Refrigerator/freezer: how many (700 W running, +2,200 W to start); default 1 | |
| space_heater | No | Space heater: how many (1,800 W running); default 0 | |
| window_ac_10k | No | Window AC, 10,000 BTU: how many (1,200 W running, +1,800 W to start); default 1 | |
| central_ac_24k | No | Central AC, 24,000 BTU (2 ton): how many (3,800 W running, +4,950 W to start); default 0 | |
| central_ac_40k | No | Central AC, 40,000 BTU: how many (6,000 W running, +6,700 W to start); default 0 | |
| microwave_1000w | No | Microwave, 1,000 W: how many (1,000 W running); default 1 | |
| other_running_w | No | Other running watts (TV, router, chargers: from nameplates) (W); default 300 | |
| washing_machine | No | Washing machine: how many (1,150 W running, +2,250 W to start); default 0 | |
| other_starting_w | No | Extra starting watts of your largest other motor (0 if none) (W); default 0 | |
| sump_pump_half_hp | No | Sump pump, 1/2 HP: how many (1,050 W running, +2,200 W to start); default 0 | |
| well_pump_third_hp | No | Water well pump, 1/3 HP: how many (1,000 W running, +2,200 W to start); default 0 | |
| furnace_fan_half_hp | No | Furnace fan blower, 1/2 HP: how many (800 W running, +2,350 W to start); default 0 | |
| garage_door_half_hp | No | Garage door opener, 1/2 HP: how many (875 W running, +2,350 W to start); default 0 | |
| electric_water_heater | No | Electric water heater: how many (4,000 W running); default 0 |