Attic Ventilation Calculator (Net Free Area, Ridge & Soffit Vents)
calc_attic_ventilationHow much attic ventilation you need by the 1/150 and 1/300 rules (Florida Building Code, Residential R806.2), split into intake and exhaust, and how many vents that is for your vent products. Formula: Total net free area (sq in) = attic floor area (sq ft) × 144 ÷ 150 (or ÷ 300 under the balanced exception). Exhaust NFA = total × high share; intake NFA = the rest. Vents = ⌈NFA ÷ the net free area of one vent (or one foot of continuous vent)⌉.
Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| ratio | No | Ventilation rule; default 150; one of 150 = 1/150 (standard), 300 = 1/300 (balanced exception: 40–50% high) | |
| upper_pct | No | Share of vent area that is high (exhaust) (%); default 50 | |
| attic_floor_sqft | No | Attic floor area (vented space) (sq ft); default 1500 | |
| intake_nfa_per_unit | No | Intake vent net free area per unit or per ft of soffit vent (from the label) (sq in); default 9 | |
| exhaust_nfa_per_unit | No | Exhaust vent net free area per unit or per ft of ridge vent (from the label) (sq in); default 18 |