Attic Ventilation Calculator (Net Free Area, Ridge & Soffit Vents)
calc_attic_ventilationHow much attic ventilation you need by the 1/150 and 1/300 rules (Florida Building Code, Residential R806.2), split into intake and exhaust, and how many vents that is for your vent products. Formula: Total net free area (sq in) = attic floor area (sq ft) × 144 ÷ 150 (or ÷ 300 under the balanced exception). Exhaust NFA = total × high share; intake NFA = the rest. Vents = ⌈NFA ÷ the net free area of one vent (or one foot of continuous vent)⌉.
Tool call template
This tool declares no required parameters. Add optional parameters from the input schema as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {},
"name": "calc_attic_ventilation"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| ratio | No | Ventilation rule; default 150; one of 150 = 1/150 (standard), 300 = 1/300 (balanced exception: 40–50% high) | |
| upper_pct | No | Share of vent area that is high (exhaust) (%); default 50 | |
| attic_floor_sqft | No | Attic floor area (vented space) (sq ft); default 1500 | |
| intake_nfa_per_unit | No | Intake vent net free area per unit or per ft of soffit vent (from the label) (sq in); default 9 | |
| exhaust_nfa_per_unit | No | Exhaust vent net free area per unit or per ft of ridge vent (from the label) (sq in); default 18 |