mdr_vigilance_reporting_timeline_calculator
[EU MDR Article 87 vigilance incident reporting statutory deadlines calculator. Pure calculation, read-only, side-effect free]. Calculates strict statutory notification deadlines under Regulation (EU) 2017/745 Article 87 (public health threat: 2 days; death/deterioration: 10 days; serious incidents: 15 days) and prepares initial MIR vigilance report payloads. Usage: Pass incident awareness date and severity classification to compute exact deadline dates and EUDAMED notification requirements. Returns: JSON object with { incidentReferenceId: string, incidentSeverityType: string, statutoryDeadlineDays: number, dateOfIncidentAwarenessIso: string, statutoryDeadlineDateIso: string, isImmediateNotificationMandatory: boolean, eudamedReportingFormType: string, initialReportRequiredContent: object }.
Tool call template
Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {
"incidentReferenceId": "<incidentReferenceId>",
"deviceName": "<deviceName>",
"manufacturerName": "<manufacturerName>",
"dateOfIncidentAwarenessIso": "<dateOfIncidentAwarenessIso>",
"incidentSeverityType": "<incidentSeverityType>",
"isDeviceCausalRelationshipEstablishedOrSuspected": "<isDeviceCausalRelationshipEstablishedOrSuspected>",
"isFieldSafetyCorrectiveActionPlanned": "<isFieldSafetyCorrectiveActionPlanned>",
"reportingToMemberStateCompetentAuthorityIso2": "<reportingToMemberStateCompetentAuthorityIso2>"
},
"name": "mdr_vigilance_reporting_timeline_calculator"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| deviceName | Yes | Commercial name and model of the medical device involved | |
| manufacturerName | Yes | Legal name of the manufacturer or EU Authorized Representative | |
| incidentReferenceId | Yes | Internal complaint or vigilance file reference identifier | |
| incidentSeverityType | Yes | Incident severity category ex MDR Article 87(3)-(5) | |
| dateOfIncidentAwarenessIso | Yes | Date when manufacturer first became aware of the incident (YYYY-MM-DD) | |
| isFieldSafetyCorrectiveActionPlanned | Yes | Whether a Field Safety Corrective Action (FSCA) and Field Safety Notice (FSN) are being initiated (Art. 87(8)) | |
| reportingToMemberStateCompetentAuthorityIso2 | Yes | 2-letter ISO country code of national competent authority receiving notification | |
| isDeviceCausalRelationshipEstablishedOrSuspected | Yes | Whether a causal link between device and incident is established or reasonably possible |