G98, G99 or EV and heat pump notification?
check_grid_connectionFor solar PV, batteries, V2G chargers, EV chargers and heat pumps in Great Britain: says which network operator process applies and when. Generation: G98 (fully type tested, 16 A / 3.68 kW per phase or less: install, then notify within 28 days) or G99 (apply and wait for acceptance before installing), counting existing generation and battery inverters. Demand: the ENA EV charge point and heat pump form (connect and notify within 28 days if every criterion is met, otherwise apply first), with each criterion marked true, false or null (not yet known). Returns generation, demand, facts_to_put_on_the_form (prefilled from inputs and trade), missing_facts and sources. Example: 5 kW solar plus a 5 kW battery inverter on single phase: {"supply_phases":1,"new_equipment":[{"type":"solar_pv","rating_kw":5,"type_tested":true},{"type":"battery","rating_kw":5,"type_tested":true}]}.
Tool call template
Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {
"new_equipment": "<new_equipment>"
},
"name": "check_grid_connection"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| mpan | No | Meter point administration number (the supply number on the bill). | |
| trade | No | Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack. | |
| nation | No | Defaults to great_britain. | |
| metered | No | The supply is metered (defaults to unknown). | |
| earthing | No | Supply earthing, for example TN-C-S. | |
| ct_metered | No | ||
| new_equipment | Yes | Equipment being installed. | |
| site_postcode | No | ||
| supply_phases | No | Defaults to 1. | |
| looped_service | No | The supply is looped with a neighbour. | |
| export_limit_kw | No | Export limit if an export limiting scheme (G100) is fitted. | |
| cut_out_rating_a | No | Network cut-out fuse rating, amps. Do not open the cut-out to find it. | |
| multiple_premises | No | Part of several installations in a close area (housing development, street-wide scheme). | |
| commissioning_date | No | YYYY-MM-DD. | |
| existing_equipment | No | Generation, storage or chargers already at the premises, same shape as new_equipment. | |
| max_demand_after_a | No | Premises maximum demand after the installation, amps per phase (from a load survey). | |
| battery_storage_kwh | No | ||
| load_limiting_device | No | A load limiting or curtailment device keeps demand below the cut-out rating. | |
| service_equipment_ok | No | No safety or adequacy concerns with the cut-out and service cable. | |
| heat_pump_single_controller | No |