Skip to main content
Glama

Simulate Grid to Capital Shock

simulate_grid_to_capital_shock
Read-onlyIdempotent

Simulates how changes in load MW, transformer lead times, queue cluster backlog, power prices, or interest rates affect a project's energization schedule, completion probability, and financial returns. Pass any project name, alias, ID, or city.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "simulate_grid_to_capital_shock"
  }
}

Input Schema

NameRequiredDescriptionDefault
siteNoProject name, site name, city, county, or canonical ID (e.g. 'Stargate Abilene', 'Columbus, OH', 'Loudoun County, VA').
queryNoProject name, alias, or location query (e.g. 'Stargate Abilene', 'Dallas, TX').
stateNoTwo-letter US state postal code (e.g. 'TX', 'VA', 'OH').
base_mwNoBaseline project IT load in megawatts before applying shock (e.g. 200).
projectNoProject name, alias, canonical project ID, Map project ID, queue ID, or developer plus place (e.g. 'Stargate Abilene', 'Hyperion', 'AXP-US-LA-00003', 'QTS Atlanta').
delta_mwNoChange in campus load in megawatts between -10000 and 10000 (e.g. 150).
locationNoCity, county, or location name (e.g. 'Dallas, TX', 'Abilene, TX').
project_idNoProject ID, canonical ID, or project name (e.g. 'P017', 'AXP-US-TX-00040', 'Stargate Abilene').
project_nameNoProject or campus name (e.g. 'Downtown Dallas Data Center: DFW1', 'Hyperion').
wacc_delta_bpsNoShock to weighted average cost of capital in basis points (e.g. 150).
canonical_project_idNoCanonical AIxEnergy project ID (e.g. 'AXP-US-TX-00101').
delta_cluster_load_mwNoChange in competing cluster queue load in megawatts (e.g. 1500).
enable_btm_flexibilityNoWhether behind-the-meter generation or load curtailment flexibility is active.
delta_interest_rate_bpsNoShock to financing interest rate in basis points (e.g. 100).
delta_nodal_basis_usd_mwhNoShock to nodal LMP congestion spread in USD/MWh (e.g. 15.0).
delta_transformer_lead_weeksNoShock to high-voltage transformer lead time in weeks (e.g. 26).
nodal_lmp_basis_spread_deltaNoShock to nodal LMP basis spread in USD/MWh (e.g. 12.5).
transformer_lead_time_months_deltaNoShock to high-voltage transformer delivery lead time in months (e.g. 6).
interconnection_queue_cluster_mw_deltaNoShock to competing local interconnection cluster backlog in MW (e.g. 1000).

Output Schema

NameRequiredDescriptionDefault
statusNoExecution status (OK, SUCCESS, RESOLVED, AMBIGUOUS_ENTITY, NOT_FOUND, ERROR).
project_idNo
_provenanceYes
project_nameNo
using_projectNoBanner confirming the resolved project name, city, state, and canonical ID when a project was matched.
next_useful_toolsNoSuggested follow-up MCP tools relevant to this result.
canonical_project_idNoCanonical AIxEnergy project identifier (e.g. 'AXP-US-LA-00003').
stage_1_load_and_coolingNo
stage_4_capital_dcf_impactNo
stage_3_queue_schedule_impactNo
stage_2_grid_and_substation_propagationNo

Schema Changelog

Changes observed during successful MCP inspections.

  1. Changed44 schema fields changed
    • addedInput schema / properties / base_mw / description
      Added value: +"Baseline project IT load in megawatts before applying shock (e.g. 200)."
    • addedInput schema / properties / base_mw / examples
      Added value: +[
      +  200
      +]
    • addedInput schema / properties / canonical_project_id / description
      Added value: +"Canonical AIxEnergy project ID (e.g. 'AXP-US-TX-00101')."
    • addedInput schema / properties / canonical_project_id / examples
      Added value: +[
      +  "AXP-US-TX-00101"
      +]
    • addedInput schema / properties / delta_cluster_load_mw / description
      Added value: +"Change in competing cluster queue load in megawatts (e.g. 1500)."
    • addedInput schema / properties / delta_cluster_load_mw / examples
      Added value: +[
      +  1500
      +]
    • addedInput schema / properties / delta_interest_rate_bps / description
      Added value: +"Shock to financing interest rate in basis points (e.g. 100)."
    • addedInput schema / properties / delta_interest_rate_bps / examples
      Added value: +[
      +  100
      +]
    • addedInput schema / properties / delta_mw / description
      Added value: +"Change in campus load in megawatts between -10000 and 10000 (e.g. 150)."
    • addedInput schema / properties / delta_mw / examples
      Added value: +[
      +  150
      +]
    • addedInput schema / properties / delta_nodal_basis_usd_mwh / description
      Added value: +"Shock to nodal LMP congestion spread in USD/MWh (e.g. 15.0)."
    • addedInput schema / properties / delta_nodal_basis_usd_mwh / examples
      Added value: +[
      +  15
      +]
    • addedInput schema / properties / delta_transformer_lead_weeks / description
      Added value: +"Shock to high-voltage transformer lead time in weeks (e.g. 26)."
    • addedInput schema / properties / delta_transformer_lead_weeks / examples
      Added value: +[
      +  26
      +]
    • addedInput schema / properties / enable_btm_flexibility / description
      Added value: +"Whether behind-the-meter generation or load curtailment flexibility is active."
    • addedInput schema / properties / interconnection_queue_cluster_mw_delta / description
      Added value: +"Shock to competing local interconnection cluster backlog in MW (e.g. 1000)."
    • addedInput schema / properties / interconnection_queue_cluster_mw_delta / examples
      Added value: +[
      +  1000
      +]
    • addedInput schema / properties / location / description
      Added value: +"City, county, or location name (e.g. 'Dallas, TX', 'Abilene, TX')."
    • addedInput schema / properties / location / examples
      Added value: +[
      +  "Dallas, TX",
      +  "Abilene, TX"
      +]
    • addedInput schema / properties / nodal_lmp_basis_spread_delta / description
      Added value: +"Shock to nodal LMP basis spread in USD/MWh (e.g. 12.5)."
    • addedInput schema / properties / nodal_lmp_basis_spread_delta / examples
      Added value: +[
      +  12.5
      +]
    • addedInput schema / properties / project
      Added value: +{
      +  "description": "Project name, alias, canonical project ID, Map project ID, queue ID, or developer plus place (e.g. 'Stargate Abilene', 'Hyperion', 'AXP-US-LA-00003', 'QTS Atlanta').",
      +  "examples": [
      +    "Stargate Abilene",
      +    "Hyperion",
      +    "AXP-US-LA-00003"
      +  ],
      +  "maxLength": 200,
      +  "type": "string"
      +}
    • addedInput schema / properties / project_id / description
      Added value: +"Project ID, canonical ID, or project name (e.g. 'P017', 'AXP-US-TX-00040', 'Stargate Abilene')."
    • addedInput schema / properties / project_id / examples
      Added value: +[
      +  "P017",
      +  "AXP-US-TX-00040",
      +  "Stargate Abilene"
      +]
    • addedInput schema / properties / project_name
      Added value: +{
      +  "description": "Project or campus name (e.g. 'Downtown Dallas Data Center: DFW1', 'Hyperion').",
      +  "examples": [
      +    "Downtown Dallas Data Center: DFW1",
      +    "Hyperion"
      +  ],
      +  "maxLength": 200,
      +  "type": "string"
      +}
    • addedInput schema / properties / query / description
      Added value: +"Project name, alias, or location query (e.g. 'Stargate Abilene', 'Dallas, TX')."
    • addedInput schema / properties / query / examples
      Added value: +[
      +  "Stargate Abilene",
      +  "Dallas, TX"
      +]
    • addedInput schema / properties / site
      Added value: +{
      +  "description": "Project name, site name, city, county, or canonical ID (e.g. 'Stargate Abilene', 'Columbus, OH', 'Loudoun County, VA').",
      +  "examples": [
      +    "Stargate Abilene",
      +    "Columbus, OH",
      +    "Loudoun County, VA"
      +  ],
      +  "maxLength": 200,
      +  "type": "string"
      +}
    • addedInput schema / properties / state / description
      Added value: +"Two-letter US state postal code (e.g. 'TX', 'VA', 'OH')."
    • addedInput schema / properties / state / examples
      Added value: +[
      +  "TX",
      +  "VA",
      +  "OH"
      +]
    • addedInput schema / properties / transformer_lead_time_months_delta / description
      Added value: +"Shock to high-voltage transformer delivery lead time in months (e.g. 6)."
    • addedInput schema / properties / transformer_lead_time_months_delta / examples
      Added value: +[
      +  6
      +]
    • addedInput schema / properties / wacc_delta_bps / description
      Added value: +"Shock to weighted average cost of capital in basis points (e.g. 150)."
    • addedInput schema / properties / wacc_delta_bps / examples
      Added value: +[
      +  150
      +]
    • addedOutput schema / properties / canonical_project_id
      Added value: +{
      +  "description": "Canonical AIxEnergy project identifier (e.g. 'AXP-US-LA-00003').",
      +  "type": [
      +    "string",
      +    "null"
      +  ]
      +}
    • addedOutput schema / properties / next_useful_tools
      Added value: +{
      +  "description": "Suggested follow-up MCP tools relevant to this result.",
      +  "items": {
      +    "type": "string"
      +  },
      +  "type": "array"
      +}
    • addedOutput schema / properties / project_id
      Added value: +{
      +  "type": "string"
      +}
    • addedOutput schema / properties / project_name
      Added value: +{
      +  "type": "string"
      +}
    • addedOutput schema / properties / stage_1_load_and_cooling
      Added value: +{
      +  "type": "object"
      +}
    • addedOutput schema / properties / stage_2_grid_and_substation_propagation
      Added value: +{
      +  "type": "object"
      +}
    • addedOutput schema / properties / stage_3_queue_schedule_impact
      Added value: +{
      +  "type": "object"
      +}
    • addedOutput schema / properties / stage_4_capital_dcf_impact
      Added value: +{
      +  "type": "object"
      +}
    • changedOutput schema / properties / status / description
      Previous value: -"Execution status (OK, NOT_FOUND, ERROR, etc.)"New value: +"Execution status (OK, SUCCESS, RESOLVED, AMBIGUOUS_ENTITY, NOT_FOUND, ERROR)."
    • addedOutput schema / properties / using_project
      Added value: +{
      +  "description": "Banner confirming the resolved project name, city, state, and canonical ID when a project was matched.",
      +  "type": [
      +    "string",
      +    "null"
      +  ]
      +}
  2. First observed

TDQS

A3.6/5.0
Behavior3/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare readOnlyHint, idempotentHint, destructiveHint=false, and openWorldHint=false, so the safe-read profile is covered. The description adds that this is a simulation over named risk levers, which is consistent with the annotations, but it does not state what happens to shocks that are left unspecified (presumably zero), whether results are persisted, or whether any runtime/auth constraints exist.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness5/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Two sentences, front-loaded with the outcome-relevant purpose, then the identifier-shortcut hint. No filler, no restatement of the title.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

Output schema and full schema descriptions mean return values and individual parameters need no explanation here. However, for a 19-parameter scenario simulator with all parameters optional, the description omits the baseline/default behavior (what a call with no shocks returns) and the aliasing relationships among shock parameters, which an agent needs to invoke it confidently.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 100%, so the baseline is 3; the description earns above baseline with "Pass any project name, alias, ID, or city", which tells the agent that the seven identifier-looking parameters (site, query, project, project_id, project_name, location, canonical_project_id) are interchangeable addressing forms rather than distinct inputs. It does not clarify the near-duplicate shock parameter pairs (e.g. delta_nodal_basis_usd_mwh vs nodal_lmp_basis_spread_delta, delta_transformer_lead_weeks vs transformer_lead_time_months_delta), leaving genuine ambiguity for a 19-parameter tool.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

Names a specific verb ("Simulates") and enumerates both the shock levers (load MW, transformer lead times, queue cluster backlog, power prices, interest rates) and the outcomes affected (energization schedule, completion probability, financial returns). An agent knows exactly what this tool produces, though it never contrasts itself with the closely related underwrite_project_and_queue or assess_site_feasibility siblings.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Usage is only implied: the framing of "shock" inputs signals scenario/stress-test analysis, so an agent can infer this is the counterfactual tool rather than a static underwriting tool. There is no explicit when-to-use, when-not-to-use, or named alternative among the many siblings.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.

Resources