Skip to main content
Glama

Assess Site Feasibility

assess_site_feasibility
Read-onlyIdempotent

Evaluates whether a candidate site or project location can support a target MW load, returning time-to-power estimates, composite site scores, nearby substations, water stress, and zoning risks. Pass a city, coordinates, or project name.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "assess_site_feasibility"
  }
}

Input Schema

NameRequiredDescriptionDefault
cityNoCity name (e.g. 'Columbus', 'Ashburn', 'Dallas').
siteNoProject name, site name, city, county, or canonical ID (e.g. 'Stargate Abilene', 'Columbus, OH', 'Loudoun County, VA').
queryNoNatural language screening query or project name (e.g. 'Screen 400 MW in Columbus, OH').
stateNoTwo-letter US state postal code (e.g. 'OH', 'VA', 'TX').
marketNoWholesale ISO/RTO market code (e.g. 'PJM', 'ERCOT').
addressNoStreet address, county, or site description.
load_mwNoProposed peak electrical load in megawatts (default: 100).
projectNoProject name, alias, canonical project ID, Map project ID, queue ID, or developer plus place (e.g. 'Stargate Abilene', 'Hyperion', 'AXP-US-LA-00003', 'QTS Atlanta').
latitudeNoSite latitude in decimal degrees WGS84 (e.g. 39.9612).
locationNoCity, county, or regional market name (e.g. 'Columbus, OH', 'Ashburn, VA').
longitudeNoSite longitude in decimal degrees WGS84 (e.g. -82.9988).
target_mwNoAlias for target electrical load in megawatts (e.g. 400).
project_idNoOptional project ID or canonical ID to evaluate at its coordinates (e.g. 'P017').
cooling_typeNoPreferred cooling system type (e.g. 'direct_liquid', 'air_cooled').
project_nameNoOptional project name to evaluate (e.g. 'Stargate Abilene').
cooling_assumptionNoAssumed cooling architecture (e.g. 'direct_liquid', 'air_cooled', 'evaporative').
canonical_project_idNoOptional canonical project ID (e.g. 'AXP-US-TX-00101').
target_energization_yearNoTarget initial energization year (e.g. 2028).
include_opportunity_matrixNoInclude Time-to-Power vs Composite Site Score arbitrage matrix.
target_initial_energization_dateNoTarget initial energization year or ISO date (e.g. 2028 or '2028-06-01').

Output Schema

NameRequiredDescriptionDefault
statusNoExecution status (OK, SUCCESS, RESOLVED, AMBIGUOUS_ENTITY, NOT_FOUND, ERROR).
_provenanceYes
using_projectNoBanner confirming the resolved project name, city, state, and canonical ID when a project was matched.
next_useful_toolsNoSuggested follow-up MCP tools relevant to this result.
canonical_project_idNoCanonical AIxEnergy project identifier (e.g. 'AXP-US-LA-00003').
resolved_coordinatesNo
siting_opportunity_matrixNo

Schema Changelog

Changes observed during successful MCP inspections.

  1. Changed40 schema fields changed
    • addedInput schema / properties / address / description
      Added value: +"Street address, county, or site description."
    • addedInput schema / properties / canonical_project_id
      Added value: +{
      +  "description": "Optional canonical project ID (e.g. 'AXP-US-TX-00101').",
      +  "examples": [
      +    "AXP-US-TX-00101"
      +  ],
      +  "maxLength": 200,
      +  "type": "string"
      +}
    • addedInput schema / properties / city / description
      Added value: +"City name (e.g. 'Columbus', 'Ashburn', 'Dallas')."
    • addedInput schema / properties / city / examples
      Added value: +[
      +  "Columbus",
      +  "Ashburn",
      +  "Dallas"
      +]
    • addedInput schema / properties / cooling_assumption / description
      Added value: +"Assumed cooling architecture (e.g. 'direct_liquid', 'air_cooled', 'evaporative')."
    • addedInput schema / properties / cooling_assumption / examples
      Added value: +[
      +  "direct_liquid",
      +  "air_cooled",
      +  "evaporative"
      +]
    • addedInput schema / properties / cooling_type / description
      Added value: +"Preferred cooling system type (e.g. 'direct_liquid', 'air_cooled')."
    • addedInput schema / properties / cooling_type / examples
      Added value: +[
      +  "direct_liquid",
      +  "air_cooled"
      +]
    • addedInput schema / properties / include_opportunity_matrix / description
      Added value: +"Include Time-to-Power vs Composite Site Score arbitrage matrix."
    • addedInput schema / properties / latitude / description
      Added value: +"Site latitude in decimal degrees WGS84 (e.g. 39.9612)."
    • addedInput schema / properties / latitude / examples
      Added value: +[
      +  39.9612
      +]
    • addedInput schema / properties / load_mw / description
      Added value: +"Proposed peak electrical load in megawatts (default: 100)."
    • addedInput schema / properties / location / description
      Added value: +"City, county, or regional market name (e.g. 'Columbus, OH', 'Ashburn, VA')."
    • addedInput schema / properties / location / examples
      Added value: +[
      +  "Columbus, OH",
      +  "Ashburn, VA"
      +]
    • addedInput schema / properties / longitude / description
      Added value: +"Site longitude in decimal degrees WGS84 (e.g. -82.9988)."
    • addedInput schema / properties / longitude / examples
      Added value: +[
      +  82.9988
      +]
    • addedInput schema / properties / market / description
      Added value: +"Wholesale ISO/RTO market code (e.g. 'PJM', 'ERCOT')."
    • addedInput schema / properties / market / examples
      Added value: +[
      +  "PJM",
      +  "ERCOT"
      +]
    • addedInput schema / properties / project
      Added value: +{
      +  "description": "Project name, alias, canonical project ID, Map project ID, queue ID, or developer plus place (e.g. 'Stargate Abilene', 'Hyperion', 'AXP-US-LA-00003', 'QTS Atlanta').",
      +  "examples": [
      +    "Stargate Abilene",
      +    "Hyperion",
      +    "AXP-US-LA-00003"
      +  ],
      +  "maxLength": 200,
      +  "type": "string"
      +}
    • addedInput schema / properties / project_id
      Added value: +{
      +  "description": "Optional project ID or canonical ID to evaluate at its coordinates (e.g. 'P017').",
      +  "examples": [
      +    "P017"
      +  ],
      +  "maxLength": 200,
      +  "type": "string"
      +}
    • addedInput schema / properties / project_name
      Added value: +{
      +  "description": "Optional project name to evaluate (e.g. 'Stargate Abilene').",
      +  "examples": [
      +    "Stargate Abilene"
      +  ],
      +  "maxLength": 200,
      +  "type": "string"
      +}
    • addedInput schema / properties / query / description
      Added value: +"Natural language screening query or project name (e.g. 'Screen 400 MW in Columbus, OH')."
    • addedInput schema / properties / query / examples
      Added value: +[
      +  "Screen 400 MW in Columbus, OH"
      +]
    • addedInput schema / properties / site
      Added value: +{
      +  "description": "Project name, site name, city, county, or canonical ID (e.g. 'Stargate Abilene', 'Columbus, OH', 'Loudoun County, VA').",
      +  "examples": [
      +    "Stargate Abilene",
      +    "Columbus, OH",
      +    "Loudoun County, VA"
      +  ],
      +  "maxLength": 200,
      +  "type": "string"
      +}
    • addedInput schema / properties / state / description
      Added value: +"Two-letter US state postal code (e.g. 'OH', 'VA', 'TX')."
    • addedInput schema / properties / state / examples
      Added value: +[
      +  "OH",
      +  "VA",
      +  "TX"
      +]
    • addedInput schema / properties / target_energization_year / description
      Added value: +"Target initial energization year (e.g. 2028)."
    • addedInput schema / properties / target_energization_year / examples
      Added value: +[
      +  2028
      +]
    • addedInput schema / properties / target_energization_year / type
      Added value: +"string"
    • addedInput schema / properties / target_initial_energization_date / description
      Added value: +"Target initial energization year or ISO date (e.g. 2028 or '2028-06-01')."
    • addedInput schema / properties / target_initial_energization_date / examples
      Added value: +[
      +  "2028-06-01"
      +]
    • addedInput schema / properties / target_initial_energization_date / type
      Added value: +"string"
    • addedInput schema / properties / target_mw / description
      Added value: +"Alias for target electrical load in megawatts (e.g. 400)."
    • addedInput schema / properties / target_mw / examples
      Added value: +[
      +  400
      +]
    • addedOutput schema / properties / canonical_project_id
      Added value: +{
      +  "description": "Canonical AIxEnergy project identifier (e.g. 'AXP-US-LA-00003').",
      +  "type": [
      +    "string",
      +    "null"
      +  ]
      +}
    • addedOutput schema / properties / next_useful_tools
      Added value: +{
      +  "description": "Suggested follow-up MCP tools relevant to this result.",
      +  "items": {
      +    "type": "string"
      +  },
      +  "type": "array"
      +}
    • addedOutput schema / properties / resolved_coordinates
      Added value: +{
      +  "type": [
      +    "object",
      +    "null"
      +  ]
      +}
    • addedOutput schema / properties / siting_opportunity_matrix
      Added value: +{
      +  "type": [
      +    "object",
      +    "null"
      +  ]
      +}
    • changedOutput schema / properties / status / description
      Previous value: -"Execution status (OK, NOT_FOUND, ERROR, etc.)"New value: +"Execution status (OK, SUCCESS, RESOLVED, AMBIGUOUS_ENTITY, NOT_FOUND, ERROR)."
    • addedOutput schema / properties / using_project
      Added value: +{
      +  "description": "Banner confirming the resolved project name, city, state, and canonical ID when a project was matched.",
      +  "type": [
      +    "string",
      +    "null"
      +  ]
      +}
  2. First observed

TDQS

A3.7/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare the operation as read-only, idempotent, non-destructive, and closed-world, so the safety profile is covered. The description adds useful behavioral context by naming the return dimensions: time-to-power estimates, composite site scores, nearby substations, water stress, and zoning risks. It does not describe assumptions or failure modes, but it adds meaningful value beyond the annotations.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness5/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The description is two sentences with no wasted wording. The core capability is front-loaded, followed by accepted input modes. It is appropriately sized for a tool whose detailed schema and annotations provide the remaining structure.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness3/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

The tool is complex, with 20 optional parameters, but has complete schema descriptions, annotations, and an output schema to carry much of the burden. The description covers the high-level purpose and return dimensions but does not help an agent choose among overlapping input parameters or sibling tools. It is adequate but not fully complete for a tool of this complexity.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100%, so each of the 20 parameters is already documented in the input schema. The description only says to pass a city, coordinates, or project name, which adds little beyond the schema and does not clarify the many aliases or optional configuration parameters. A baseline score of 3 is appropriate when the schema carries the parameter semantics.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description states a specific verb and resource: it evaluates whether a candidate site or project location can support a target MW load. It also previews the returned dimensions, making the tool's scope clear. However, it does not explicitly distinguish this broad feasibility assessment from sibling tools such as screen_regional_capacity or audit_environmental_and_site_gates.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

The description implies usage by framing the tool as evaluating site feasibility for a target load, and it lists acceptable input modes: city, coordinates, or project name. It does not state when to use this tool versus alternatives, nor does it include exclusions or prerequisites. The guidance is therefore implied rather than explicit.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.

Resources