Check that the building is closed and roofed
cao_integriteWHEN you need the structural-integrity check alone (is the building really closed and roofed? walls that join nothing, wall clusters scattered outside the envelope, open roof, walls or volumes in each other, stairs badly placed). Returns alerts, applicable correctifs (field → value) and, with appliquer: true, the corrected scene. Free, no key. cao_verifier already includes it.
Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| murs | No | Walls: plan segments extruded vertically. Every coordinate in this whole scene is in MILLIMETRES, in a single plan frame whose origin you choose — X to the right, Y upward, Z up from the floor. Keep one consistent origin across murs/boites/plan: the generators never recentre anything for you. | |
| plan | No | 2D reference lines — drawn flat, never extruded and never counted in the quantities. Use them for axes, plot limits or setting-out marks. | |
| boites | No | Boxes (furniture, volumes): a rectangular block placed by its CENTRE, not by a corner. Millimetres, same frame as murs[]. | |
| georef | No | Optional Lambert-93 (EPSG:2154) false origin for IfcMapConversion. Local millimetres are scaled by 0.001 to CRS metres. Do not invent coordinates: omit est/nord if unknown (origin stays 0). orientation is the angle in degrees of project X from map East, counterclockwise. | |
| cercles | No | Circles on the 2D plan, alongside plan[] lines: each has a centre and a radius, in the same unit as the plan. Use for round shapes a polyline would render badly — fillets, posts, manholes. | |
| reseaux | No | Plumbing pipe runs (EF/EC/EU/EV/EP/chauffage) — used only by cao_pdf (technical plan + linear-meter quantities per type). | |
| toitures | No | Roofs — used only by cao_pdf. WITHOUT this field: a flat roof is auto-generated over the footprint of ALL walls (legacy default). WITH it: compose freely — each entry can target a subset of walls (via `murs`), letting you build an L-shaped building's roof, or add a dormer on top of a main roof. | |
| appliquer | No | Apply the proposed fixes to a copy of the scene. | |
| plomberie | No | Sanitary fixtures (sink, WC, shower…) — used only by cao_pdf. Same positioning as electricite. | |
| revalider | No | With appliquer: re-run the check on the corrected scene. | |
| decoration | No | Paint/finish per wall — used only by cao_pdf. Colors the elevations (exterior face) and the axonometric view (face auto-detected by orientation relative to the building's centroid). | |
| ouvertures | No | Doors/windows embedded in a wall — used only by cao_pdf (elevations + axonometric view), no effect on dxf/metres. | |
| electricite | No | Electrical symbols (outlets, switches, lights…) — used only by cao_pdf (dedicated technical plan + quantities), no effect on dxf/metres/render. Position: attached to a wall (`mur`+`position`, like ouvertures) or free (`x`,`y`). | |
| compositions | No | Named wall/slab layer sets declared by the project. A key that matches an inferred kind (mur_exterieur, refend, cloison, plancher, toiture) or murs[].composition drops the Hypothese flag. Each value is {libelle, couches: [{cle, epaisseur?}]}. cle: enduit, bloc_beton, isolant, ba13, ossature, enduit_platre, beton_arme, tuile, charpente, etancheite. Omit epaisseur on the load-bearing layer. |