Terminate External Building Cable Drops on Patch Panel
plan_external_endpointsTerminate external building or room cable drops onto the rear RJ45 ports of a mounted patch panel without consuming rack U slots, and optionally auto-create labeled Cat6A front patch cables to a mounted switch. 'groups[]' batch-generates drops first—with 'custom_labels[]' overriding numbered 'label_prefix' entries per index—followed by 'endpoints[]', allocating sequential free rear ports from 'start_port_number' and sequential free switch RJ45 ports from 'auto_connect_switch_start_port'. Setting 'clear_existing' destructively removes prior external drops on 'patch_panel_instance_id' and their front patch cables before allocation, while unmounted patch-panel or switch IDs return status 'INVALID' without mutating state. Use for off-rack building wiring entering the enclosure; never mount room endpoints via mount_equipment, and use connect_cables for purely internal rack-to-rack links.
Tool call template
Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {
"patch_panel_instance_id": "<patch_panel_instance_id>"
},
"name": "plan_external_endpoints"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| groups | No | Batch groups of external drops (e.g., 10x PoE cameras, 5x Wi-Fi APs, 5x room LAN outlets). | |
| endpoints | No | Individual external building/room drops to terminate on the rear of the patch panel. | |
| clear_existing | No | If true, destructively clears existing external_endpoints (and their front patch cables) on patch_panel_instance_id before planning. | |
| entry_position | No | Rear building cable conduit entry point into the rack frame. | top-rear |
| start_port_number | No | 1-indexed starting port number on the patch panel (defaults to next free rear port or 1). | |
| patch_panel_instance_id | Yes | Mounted patch panel instance_id whose rear ports receive the incoming building cable drops. | |
| auto_connect_switch_start_port | No | 1-indexed starting Ethernet port number on auto_connect_switch_instance_id (e.g., 1 for eth1). | |
| auto_connect_switch_instance_id | No | Optional switch instance_id to automatically patch from the front of the patch panel using labeled Cat6A cables. |
Output Schema
| Name | Required | Description | Default |
|---|---|---|---|
| data | Yes | External endpoint planning and auto-patching payload. | |
| issues | Yes | Structured diagnostic findings (ERROR, WARNING, INFO) with actionable remediation_suggestions. | |
| status | Yes | Deterministic execution outcome: "VALID" when the operation succeeded with 0 validation errors; "INVALID" when precondition or engineering validation errors are present in issues[]. | |
| summary | Yes | Concise human- and agent-readable summary of the tool result and validation status. |