Design the light gauge steel (cold-formed steel) framing of a house
design_lgs_framingPreliminary design of the cold-formed steel (light gauge steel, LGS) framing of a single-storey house with a gable roof on a concrete slab, in Canada: NBC 2020 Part 4 loads (snow, wind, earthquake when Sa values are given), members and screw connections to AISI S100-16 with the Canadian Appendix B (CSA S136) and AISI S240-20, Limit States Design. Frames the house (studs and tracks at 406 or 610 mm in line with Fink roof trusses, box headers with jack and king studs over every opening, full-height gable walls, bridging), analyses it and checks every member group and connection: truss chords, webs, heel and ridge gusset plates and screw groups, studs under axial load and wind, headers, gable wall studs, Type I OSB shear walls, the roof diaphragm, overall uplift and overturning. Sections not given are sized automatically (lightest SSMA S-section that passes; 43 mil and thicker studs). Returns the sections, piece count and steel mass by section, the governing utilisation ratio of each group and the ratio of every check, and which checks are conditional. Rectangular plan only, no interior load-bearing walls, roof 10 to 45 degrees, truss span 4 to 14 m, low building for wind. When wind uplift or overturning exceeds 0.9 x dead load the result says that anchorage to the foundation is required. Anchors, hold-down products, foundations, sheathing products and roll-former data are not designed. Nothing is stored. Preliminary, not signed.
Tool call template
Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {
"length_m": "<length_m>",
"width_m": "<width_m>",
"wall_height_m": "<wall_height_m>",
"loads": "<loads>"
},
"name": "design_lgs_framing"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| loads | Yes | Climatic data for the location from NBC 2020 Appendix C Table C-2, and seismic data from the NRCan 2020 seismic hazard tool. | |
| width_m | Yes | Plan width, m. The left and right walls run along the width. | |
| length_m | Yes | Plan length, out-to-out of the wall framing, m. The front and back walls run along the length. | |
| openings | No | Doors and windows (default none). position_m = distance from the left end of the wall, seen from outside, to the side of the opening; at least 0.3 m from each corner and between openings. | |
| sections | No | Optional fixed SSMA S-sections (e.g. "600S162-43"); the others are sized automatically. header = each of the two members of the box header. | |
| roof_pitch | No | Roof slope as rise:run text ("6:12") or degrees (10 to 45). Default "6:12". | |
| spacing_mm | No | Stud and truss spacing, mm: 406 (16 in) or 610 (24 in, default). | |
| ridge_along | No | Ridge direction (default the longer side). The trusses span the other side and bear on the two eave walls. | |
| stud_depth_in | No | Optional stud depth, in, when the wall thickness is fixed (default 6, then 8 if needed). | |
| wall_height_m | Yes | Wall height from the slab to the top of the wall framing, m. | |
| eave_overhang_mm | No | Eave overhang, mm (default 406). | |
| include_geometry | No | Also return the 3D geometry of every member (axis end points in mm, orientation, section, governing check) in structuredContent.geometry, for drawing the framing. Adds about 30 KB; default false. |