changedInput schema / additionalProperties
Previous value: -falseNew value: +true
addedInput schema / properties / breakerOverrides / additionalProperties
Added value: +true
changedInput schema / properties / breakerOverrides / description
Previous value: -"Dictionnaire optionnel { edgeId: \"OPEN\"|\"CLOSED\"|boolean } appliqué avant le traçage."New value: +"Optional switching override map { edgeId: \"OPEN\" | \"CLOSED\" | boolean } applied before tracing."
addedInput schema / properties / breakerOverrides / properties
Added value: +{}
changedInput schema / properties / centerId / description
Previous value: -"Nœud central pour mode neighborhood (ou full)."New value: +"Central busbar node identifier used for k-hop neighborhood and full modes."
changedInput schema / properties / edges / description
Previous value: -"Liste des branches ({ id?, source, target, type?, status?, r?, x?, z_pct?, r_ohm?, x_ohm?, r0?, x0?, length?, vector_group?, sec_kv?, mva? })."New value: +"Array of network branches and switches connecting busbar nodes (maximum 10000 edges)."
addedInput schema / properties / edges / items / additionalProperties
Added value: +true
changedInput schema / properties / edges / items / description
Previous value: -"Descripteur de branche électrique ou organe de coupure entre deux noeuds."New value: +"Branch descriptor { id?, source, target, type?, status?, r?, x?, z_pct?, r_ohm?, x_ohm?, r0?, x0?, length?, vector_group?, sec_kv?, mva? }."
addedInput schema / properties / edges / items / properties
Added value: +{
+ "source": {
+ "description": "Origin busbar node identifier.",
+ "type": "string"
+ },
+ "target": {
+ "description": "Destination node identifier.",
+ "type": "string"
+ }
+}
addedInput schema / properties / hops / default
Added value: +1
changedInput schema / properties / hops / description
Previous value: -"Nombre de sauts pour mode neighborhood (défaut: 1)."New value: +"Graph hop radius for neighborhood traversal (integer 0..20, defaults to 1)."
addedInput schema / properties / ignoreOpenStatus / default
Added value: +false
changedInput schema / properties / ignoreOpenStatus / description
Previous value: -"Autorise le repli enveloppe à travers les organes OPEN (défaut: false)."New value: +"Allow envelope fallback traversal across OPEN switching devices (defaults to false)."
addedInput schema / properties / lang / default
Added value: +"fr"
changedInput schema / properties / lang / description
Previous value: -"Langue des paliers de tension (fr|en, défaut: fr)."New value: +"Response localization language code for labels (\"fr\" or \"en\", defaults to \"fr\")."
changedInput schema / properties / mode / description
Previous value: -"Mode de traçage (déduit automatiquement de sourceId/targetId/centerId si omis)."New value: +"Graph tracing mode; automatically inferred from sourceId, targetId, and centerId when omitted."
changedInput schema / properties / nodes / description
Previous value: -"Liste des nœuds/jeux de barres ({ id, nom_kv, base_kv?, bus_type?, is_source?, label?, subsystem_index? })."New value: +"Non-empty array of electrical network busbar nodes (maximum 5000 nodes)."
addedInput schema / properties / nodes / items / additionalProperties
Added value: +true
changedInput schema / properties / nodes / items / description
Previous value: -"Descripteur de noeud ou jeu de barres du graphe topologique."New value: +"Node descriptor { id, nom_kv, base_kv?, bus_type?, is_source?, label?, subsystem_index? }."
addedInput schema / properties / nodes / items / properties
Added value: +{
+ "id": {
+ "description": "Unique busbar node identifier.",
+ "type": "string"
+ },
+ "nom_kv": {
+ "description": "Nominal line-to-line voltage in kV.",
+ "type": "number"
+ }
+}
changedInput schema / properties / preferredSourceId / description
Previous value: -"Source amont préférentielle pour mode upstream."New value: +"Preferred upstream source node identifier prioritized during upstream tracing."
changedInput schema / properties / sourceId / description
Previous value: -"Identifiant du nœud source/origine pour modes path, downstream ou full."New value: +"Origin busbar identifier used by path, downstream, and full tracing modes."
addedInput schema / properties / strictSource / default
Added value: +false
changedInput schema / properties / strictSource / description
Previous value: -"Force la source préférentielle si un chemin fermé existe en mode upstream (défaut: false)."New value: +"Force preferredSourceId when a closed path exists in upstream mode (defaults to false)."
changedInput schema / properties / targetId / description
Previous value: -"Identifiant du nœud cible pour modes path, upstream ou full."New value: +"Target busbar identifier used by path, upstream, and full tracing modes."
changedInput schema / properties / toggleEdgeIds / description
Previous value: -"Liste optionnelle d’ID de branches à basculer (OPEN <-> CLOSED) avant le traçage."New value: +"Optional branch identifiers toggled (OPEN <-> CLOSED) before graph tracing."
changedInput schema / properties / toggleEdgeIds / items / description
Previous value: -"Identifiant unique de branche dont l etat OPEN/CLOSED doit basculer."New value: +"Unique branch identifier whose OPEN/CLOSED state is toggled."
changedOutput schema / (root)
Previous value: -nullNew value: +{
+ "additionalProperties": true,
+ "description": "Topological graph paths, voltage-referred impedances, BFS levels, and MV loop diagnostics.",
+ "properties": {
+ "downstream": {
+ "additionalProperties": true,
+ "description": "Downstream energized subtree and referred path impedances.",
+ "properties": {
+ "downstreamCount": {
+ "description": "Count of energized downstream buses.",
+ "type": "integer"
+ },
+ "rootId": {
+ "description": "Origin busbar identifier.",
+ "type": "string"
+ }
+ },
+ "type": "object"
+ },
+ "edgeCount": {
+ "description": "Total count of branches evaluated in the network graph.",
+ "type": "integer"
+ },
+ "levels": {
+ "description": "BFS hierarchical depth summary rows.",
+ "items": {
+ "additionalProperties": true,
+ "description": "Busbar BFS hierarchy row.",
+ "properties": {
+ "depth": {
+ "description": "BFS hierarchical depth level.",
+ "type": "integer"
+ },
+ "id": {
+ "description": "Busbar node identifier string.",
+ "type": "string"
+ }
+ },
+ "type": "object"
+ },
+ "type": "array"
+ },
+ "maxDepth": {
+ "description": "Maximum BFS topological depth from energized sources.",
+ "type": "integer"
+ },
+ "mode": {
+ "description": "Executed or inferred graph traversal mode.",
+ "type": "string"
+ },
+ "mvRamesAndLoops": {
+ "additionalProperties": true,
+ "description": "MV switchboard sections, internal loops, and 3Ic0 galvanic zones.",
+ "properties": {
+ "couplingMode": {
+ "description": "MV switchboard coupling state.",
+ "type": "string"
+ },
+ "rames": {
+ "description": "Detected MV bus sections and galvanic zones.",
+ "items": {
+ "additionalProperties": true,
+ "description": "MV busbar section descriptor.",
+ "properties": {
+ "nomKv": {
+ "description": "Nominal MV voltage in kV.",
+ "type": "number"
+ },
+ "rameId": {
+ "description": "MV busbar section identifier.",
+ "type": "string"
+ }
+ },
+ "type": "object"
+ },
+ "type": "array"
+ }
+ },
+ "type": "object"
+ },
+ "neighborhood": {
+ "additionalProperties": true,
+ "description": "K-hop graph neighborhood node and branch identifiers.",
+ "properties": {
+ "centerId": {
+ "description": "Center busbar node identifier.",
+ "type": "string"
+ },
+ "hops": {
+ "description": "Applied graph hop radius.",
+ "type": "integer"
+ },
+ "nodeIds": {
+ "description": "Nodes located within k hops.",
+ "items": {
+ "description": "Neighbor busbar node identifier.",
+ "type": "string"
+ },
+ "type": "array"
+ }
+ },
+ "type": "object"
+ },
+ "nodeCount": {
+ "description": "Total count of busbar nodes evaluated in the network graph.",
+ "type": "integer"
+ },
+ "openBranchCount": {
+ "description": "Number of branches in OPEN state after applying overrides.",
+ "type": "integer"
+ },
+ "path": {
+ "additionalProperties": true,
+ "description": "Summarized electrical path with voltage-referred positive and zero-sequence impedances.",
+ "properties": {
+ "pathNodes": {
+ "description": "Ordered sequence of traversed busbar IDs.",
+ "items": {
+ "description": "Ordered busbar identifier along the path.",
+ "type": "string"
+ },
+ "type": "array"
+ },
+ "referredBaseKv": {
+ "description": "Target reference voltage level in kV to which impedances are referred.",
+ "type": "number"
+ },
+ "sourceId": {
+ "description": "Origin busbar node identifier for the traced electrical path.",
+ "type": "string"
+ },
+ "stepsCount": {
+ "description": "Number of electrical branches traversed along the path.",
+ "type": "integer"
+ },
+ "targetId": {
+ "description": "Destination busbar node identifier for the traced electrical path.",
+ "type": "string"
+ },
+ "totalRReferredOhm": {
+ "description": "Cumulative positive-sequence resistance referred to target kV in Ohms.",
+ "type": "number"
+ },
+ "totalXReferredOhm": {
+ "description": "Cumulative positive-sequence reactance referred to target kV in Ohms.",
+ "type": "number"
+ },
+ "totalZ0ReferredOhm": {
+ "description": "Cumulative zero-sequence impedance magnitude referred in Ohms.",
+ "type": "number"
+ },
+ "totalZReferredOhm": {
+ "description": "Cumulative positive-sequence impedance magnitude referred in Ohms.",
+ "type": "number"
+ },
+ "zeroSeqBlocked": {
+ "description": "True if a transformer winding along the path blocks zero-sequence current.",
+ "type": "boolean"
+ }
+ },
+ "type": "object"
+ },
+ "reachable": {
+ "description": "True when targetId is reachable from sourceId in path mode.",
+ "type": "boolean"
+ },
+ "upstream": {
+ "additionalProperties": true,
+ "description": "Upstream source path and ancestor busbar list.",
+ "properties": {
+ "ancestorNodeIds": {
+ "description": "Ordered upstream ancestor busbar identifiers.",
+ "items": {
+ "description": "Upstream ancestor busbar ID.",
+ "type": "string"
+ },
+ "type": "array"
+ },
+ "bestSourcePath": {
+ "additionalProperties": true,
+ "description": "Summarized electrical path with voltage-referred positive and zero-sequence impedances.",
+ "properties": {
+ "pathNodes": {
+ "description": "Ordered sequence of traversed busbar IDs.",
+ "items": {
+ "description": "Ordered busbar identifier along the path.",
+ "type": "string"
+ },
+ "type": "array"
+ },
+ "referredBaseKv": {
+ "description": "Target reference voltage level in kV to which impedances are referred.",
+ "type": "number"
+ },
+ "sourceId": {
+ "description": "Origin busbar node identifier for the traced electrical path.",
+ "type": "string"
+ },
+ "stepsCount": {
+ "description": "Number of electrical branches traversed along the path.",
+ "type": "integer"
+ },
+ "targetId": {
+ "description": "Destination busbar node identifier for the traced electrical path.",
+ "type": "string"
+ },
+ "totalRReferredOhm": {
+ "description": "Cumulative positive-sequence resistance referred to target kV in Ohms.",
+ "type": "number"
+ },
+ "totalXReferredOhm": {
+ "description": "Cumulative positive-sequence reactance referred to target kV in Ohms.",
+ "type": "number"
+ },
+ "totalZ0ReferredOhm": {
+ "description": "Cumulative zero-sequence impedance magnitude referred in Ohms.",
+ "type": "number"
+ },
+ "totalZReferredOhm": {
+ "description": "Cumulative positive-sequence impedance magnitude referred in Ohms.",
+ "type": "number"
+ },
+ "zeroSeqBlocked": {
+ "description": "True if a transformer winding along the path blocks zero-sequence current.",
+ "type": "boolean"
+ }
+ },
+ "type": "object"
+ }
+ },
+ "type": "object"
+ },
+ "zeroSeqBlockingEdgeIds": {
+ "description": "Transformer branch IDs that block zero-sequence current.",
+ "items": {
+ "description": "Branch ID blocking zero-sequence continuity.",
+ "type": "string"
+ },
+ "type": "array"
+ }
+ },
+ "type": "object"
+}