changedInput schema / properties / busId / description
Previous value: -"Identifiant du jeu de barres pour l’analyse homopolaire."New value: +"MV switchboard busbar identifier evaluated during homopolar earth-fault grading."
changedInput schema / properties / current / description
Previous value: -"Courant d’essai en ampères (A) pour calcul de temps TCC."New value: +"Test fault current in primary amperes (A) for TCC tripping evaluation."
addedInput schema / properties / current / maximum
Added value: +500000
addedInput schema / properties / current / minimum
Added value: +0.001
changedInput schema / properties / curveCode / description
Previous value: -"Code courbe IEC/modèle analytique/Spéciale (SI, VI, EI, LTI, IEEE_MI, IEEE_VI, IEEE_EI, RI, IEC_STI, US_CO8, US_CO2_P20, US_CO2_P40)."New value: +"Inverse time-current curve family identifier such as SI, VI, EI, LTI, DT, RI, or US_CO8."
addedInput schema / properties / deltaTTarget / default
Added value: +0.2
changedInput schema / properties / deltaTTarget / description
Previous value: -"Marge chronométrique cible Δt (s), défaut 0.20."New value: +"Target chronometric selectivity time margin delta-t in s (defaults to 0.20 s)."
addedInput schema / properties / deltaTTarget / maximum
Added value: +30
addedInput schema / properties / deltaTTarget / minimum
Added value: +0.01
addedInput schema / properties / downstreamRelay / additionalProperties
Added value: +true
changedInput schema / properties / downstreamRelay / description
Previous value: -"Réglages relais aval."New value: +"Protective relay curve family, pickup, TMS, definite delay, and instantaneous settings."
addedInput schema / properties / downstreamRelay / properties
Added value: +{
+ "curveType": {
+ "description": "Time-current curve identifier such as SI, VI, EI, LTI, DT, or RI.",
+ "type": "string"
+ },
+ "delayS": {
+ "description": "Definite-time trip delay in seconds (s).",
+ "minimum": 0,
+ "type": "number"
+ },
+ "instDelayS": {
+ "description": "Instantaneous high-set intentional delay in seconds (s).",
+ "minimum": 0,
+ "type": "number"
+ },
+ "instPickupA": {
+ "description": "Instantaneous high-set pickup threshold I>> in primary amperes (A).",
+ "minimum": 0,
+ "type": "number"
+ },
+ "pickupA": {
+ "description": "Overcurrent pickup threshold Is in primary amperes (A).",
+ "minimum": 0.1,
+ "type": "number"
+ },
+ "tms": {
+ "description": "Dimensionless time multiplier setting TMS for inverse-time curves.",
+ "minimum": 0.01,
+ "type": "number"
+ }
+}
changedInput schema / properties / feeders / description
Previous value: -"Liste des départs pour analyse 3Ic0 / 51N / 67N."New value: +"List of MV feeders evaluated for 3Ic0 capacitive return and 51N/67N earth-fault selectivity."
addedInput schema / properties / feeders / items
Added value: +{
+ "additionalProperties": true,
+ "description": "MV feeder zero-sequence capacitive and earth-fault coordination entry.",
+ "properties": {
+ "id": {
+ "description": "Unique MV feeder bay identifier (e.g. \"FEEDER_01\").",
+ "type": "string"
+ },
+ "lengthM": {
+ "description": "Feeder cable route length in meters (m) for 3Ic0 estimation.",
+ "minimum": 0,
+ "type": "number"
+ },
+ "threeI0MinAmp": {
+ "description": "Minimum earth-fault current seen on the feeder in amperes (A).",
+ "minimum": 0,
+ "type": "number"
+ },
+ "threeIc0Amp": {
+ "description": "Measured or precomputed zero-sequence capacitive current 3Ic0 in amperes (A).",
+ "minimum": 0,
+ "type": "number"
+ }
+ },
+ "type": "object"
+}
addedInput schema / properties / groundingInfo / additionalProperties
Added value: +true
changedInput schema / properties / groundingInfo / description
Previous value: -"Paramètres de mise à la terre du neutre (type, neutralLimitA, bpnAmp...)."New value: +"Neutral earthing scheme parameters (type, neutralLimitA, bpnAmp, and RCA angle)."
addedInput schema / properties / groundingInfo / properties
Added value: +{
+ "neutralLimitA": {
+ "description": "Neutral resistor or reactor earth-fault limit current in amperes (A).",
+ "minimum": 0,
+ "type": "number"
+ },
+ "type": {
+ "description": "Neutral earthing mode (\"bpn\", \"compensated\", \"isolated\", or \"solid\").",
+ "type": "string"
+ }
+}
changedInput schema / properties / ik / description
Previous value: -"Courant permanent Ik (kA) pour switchboard_withstand."New value: +"Steady-state symmetrical short-circuit current Ik in kiloamperes (kA)."
addedInput schema / properties / ik / minimum
Added value: +0.01
addedInput schema / properties / ikMax / default
Added value: +20000
changedInput schema / properties / ikMax / description
Previous value: -"Courant court-circuit max Ik3_max (A), défaut 20000."New value: +"Maximum prospective three-phase fault current Ik3_max in A (defaults to 20000 A)."
addedInput schema / properties / ikMax / maximum
Added value: +500000
addedInput schema / properties / ikMax / minimum
Added value: +1
addedInput schema / properties / ikMin / default
Added value: +1000
changedInput schema / properties / ikMin / description
Previous value: -"Courant court-circuit min Ik2_min (A), défaut 1000."New value: +"Minimum prospective two-phase fault current Ik2_min in A (defaults to 1000 A)."
addedInput schema / properties / ikMin / maximum
Added value: +500000
addedInput schema / properties / ikMin / minimum
Added value: +1
addedInput schema / properties / includeCatalog / default
Added value: +false
changedInput schema / properties / includeCatalog / description
Previous value: -"Inclut la liste des courbes IEC/modèle analytique disponibles."New value: +"True to include the list of available time-current curve codes (defaults to false)."
changedInput schema / properties / ip / description
Previous value: -"Courant de crête Ip (kA) pour switchboard_withstand."New value: +"Asymmetrical peak short-circuit current Ip in kiloamperes (kA)."
addedInput schema / properties / ip / minimum
Added value: +0.01
changedInput schema / properties / ippk / description
Previous value: -"Courant crête Ipk ou Ik\" (kA) pour switchboard_withstand."New value: +"Prospective initial symmetrical fault current Ik\" in kiloamperes (kA)."
addedInput schema / properties / ippk / minimum
Added value: +0.01
changedInput schema / properties / ithRatedKa / description
Previous value: -"Tenue thermique assignée tableau Ith (kA)."New value: +"Switchboard rated short-time thermal withstand current Ith in kiloamperes (kA)."
addedInput schema / properties / ithRatedKa / minimum
Added value: +0.1
addedInput schema / properties / lang / default
Added value: +"fr"
changedInput schema / properties / lang / description
Previous value: -"Langue des diagnostics (fr|en)."New value: +"Localization language code for labels and diagnostics (\"fr\" or \"en\", defaults to \"fr\")."
addedInput schema / properties / mode / default
Added value: +"coordination_pair"
changedInput schema / properties / mode / description
Previous value: -"Mode d’analyse souhaité (défaut: coordination_pair si amont/aval fournis, sinon single_curve/homopolar)."New value: +"Analysis mode: single_curve, coordination_pair, homopolar, full, relay_time, special_curve, solve_tms, switchboard_withstand, or inverse-time curve lookup (defaults to \"coordination_pair\")."
removedInput schema / properties / mode / enum
Removed value: -[
- "single_curve",
- "coordination_pair",
- "homopolar",
- "full",
- "relay_time",
- "iec_curve",
- "ieee_curve",
- "special_curve",
- "solve_tms",
- "switchboard_withstand"
-]
changedInput schema / properties / pickup / description
Previous value: -"Seuil de démarrage Is (A) pour modes Brain iec_curve / ieee_curve / special_curve / solve_tms / relay_time."New value: +"Relay startup pickup threshold Is in primary amperes (A)."
addedInput schema / properties / pickup / minimum
Added value: +0.001
addedInput schema / properties / relay / additionalProperties
Added value: +true
changedInput schema / properties / relay / description
Previous value: -"Réglages relais unique (curveType, pickupA, tms, delayS, instPickupA, instDelayS...)."New value: +"Protective relay curve family, pickup, TMS, definite delay, and instantaneous settings."
addedInput schema / properties / relay / properties
Added value: +{
+ "curveType": {
+ "description": "Time-current curve identifier such as SI, VI, EI, LTI, DT, or RI.",
+ "type": "string"
+ },
+ "delayS": {
+ "description": "Definite-time trip delay in seconds (s).",
+ "minimum": 0,
+ "type": "number"
+ },
+ "instDelayS": {
+ "description": "Instantaneous high-set intentional delay in seconds (s).",
+ "minimum": 0,
+ "type": "number"
+ },
+ "instPickupA": {
+ "description": "Instantaneous high-set pickup threshold I>> in primary amperes (A).",
+ "minimum": 0,
+ "type": "number"
+ },
+ "pickupA": {
+ "description": "Overcurrent pickup threshold Is in primary amperes (A).",
+ "minimum": 0.1,
+ "type": "number"
+ },
+ "tms": {
+ "description": "Dimensionless time multiplier setting TMS for inverse-time curves.",
+ "minimum": 0.01,
+ "type": "number"
+ }
+}
changedInput schema / properties / targetTimeS / description
Previous value: -"Temps cible t (s) pour le solveur analytique solve_tms."New value: +"Target relay operating time t in seconds (s) for analytical solve_tms."
addedInput schema / properties / targetTimeS / minimum
Added value: +0.001
addedInput schema / properties / td / default
Added value: +1
changedInput schema / properties / td / description
Previous value: -"Time Dial (modèle analytique)."New value: +"US time-dial multiplier TD for inverse-time curves (defaults to 1.0)."
addedInput schema / properties / td / minimum
Added value: +0.01
changedInput schema / properties / tk / description
Previous value: -"Durée court-circuit Tk (s) pour vérification tenue tableau."New value: +"Short-circuit fault clearing duration Tk in seconds (s) for switchboard withstand."
addedInput schema / properties / tk / minimum
Added value: +0.01
changedInput schema / properties / tkRated / description
Previous value: -"Durée assignée tenue tableau (s)."New value: +"Switchboard rated short-time withstand duration in seconds (s)."
addedInput schema / properties / tkRated / minimum
Added value: +0.01
addedInput schema / properties / tms / default
Added value: +1
changedInput schema / properties / tms / description
Previous value: -"Time Multiplier Setting (IEC / RI)."New value: +"Dimensionless time multiplier setting TMS (defaults to 1.0)."
addedInput schema / properties / tms / minimum
Added value: +0.01
addedInput schema / properties / upstreamRelay / additionalProperties
Added value: +true
changedInput schema / properties / upstreamRelay / description
Previous value: -"Réglages relais amont."New value: +"Protective relay curve family, pickup, TMS, definite delay, and instantaneous settings."
addedInput schema / properties / upstreamRelay / properties
Added value: +{
+ "curveType": {
+ "description": "Time-current curve identifier such as SI, VI, EI, LTI, DT, or RI.",
+ "type": "string"
+ },
+ "delayS": {
+ "description": "Definite-time trip delay in seconds (s).",
+ "minimum": 0,
+ "type": "number"
+ },
+ "instDelayS": {
+ "description": "Instantaneous high-set intentional delay in seconds (s).",
+ "minimum": 0,
+ "type": "number"
+ },
+ "instPickupA": {
+ "description": "Instantaneous high-set pickup threshold I>> in primary amperes (A).",
+ "minimum": 0,
+ "type": "number"
+ },
+ "pickupA": {
+ "description": "Overcurrent pickup threshold Is in primary amperes (A).",
+ "minimum": 0.1,
+ "type": "number"
+ },
+ "tms": {
+ "description": "Dimensionless time multiplier setting TMS for inverse-time curves.",
+ "minimum": 0.01,
+ "type": "number"
+ }
+}
addedInput schema / properties / voltageRatioDownToUp / default
Added value: +1
changedInput schema / properties / voltageRatioDownToUp / description
Previous value: -"Rapport de tension aval/amont pour ramener le courant au primaire amont (défaut 1.0)."New value: +"Downstream-to-upstream voltage transformation ratio for current referral (defaults to 1.0)."
addedInput schema / properties / voltageRatioDownToUp / maximum
Added value: +100
addedInput schema / properties / voltageRatioDownToUp / minimum
Added value: +0.01
changedOutput schema / (root)
Previous value: -nullNew value: +{
+ "additionalProperties": true,
+ "description": "Time-current selectivity, TMS solver, and homopolar coordination result with trace and legal notice.",
+ "properties": {
+ "calculationTrace": {
+ "additionalProperties": true,
+ "description": "Transparent audit trail listing inputs, defaults, SI formulas, constants, and engineering assumptions.",
+ "properties": {
+ "defaultsApplied": {
+ "additionalProperties": true,
+ "description": "Default SI parameters injected when optional inputs are omitted.",
+ "properties": {},
+ "type": "object"
+ },
+ "engineeringAssumptions": {
+ "description": "Boundary conditions assumed by the calculation engine.",
+ "items": {
+ "description": "Validity assumption constraining interpretation.",
+ "type": "string"
+ },
+ "type": "array"
+ },
+ "formulasAndConstants": {
+ "additionalProperties": true,
+ "description": "Mathematical formulas and constants applied during evaluation.",
+ "properties": {
+ "constants": {
+ "additionalProperties": true,
+ "description": "Physical constants and conversion coefficients in SI units.",
+ "properties": {},
+ "type": "object"
+ },
+ "formulas": {
+ "description": "Evaluated physical formulas.",
+ "items": {
+ "description": "Symbolic SI physics equation.",
+ "type": "string"
+ },
+ "type": "array"
+ }
+ },
+ "type": "object"
+ },
+ "inputsProvided": {
+ "additionalProperties": true,
+ "description": "Caller-supplied parameters normalized before execution.",
+ "properties": {},
+ "type": "object"
+ },
+ "mode": {
+ "description": "Executed physics calculation sub-mode for this call.",
+ "type": "string"
+ },
+ "physicalPrinciples": {
+ "description": "Ordered physical principles backing the solver.",
+ "items": {
+ "description": "Physical principle governing the analytical model.",
+ "type": "string"
+ },
+ "type": "array"
+ },
+ "tool": {
+ "description": "Canonical MCP tool identifier recorded by the calculation tracer.",
+ "type": "string"
+ }
+ },
+ "type": "object"
+ },
+ "coordinationPair": {
+ "additionalProperties": true,
+ "description": "Two-relay coordination grading margin summary across [ikMin, ikMax].",
+ "properties": {
+ "isCoordinated": {
+ "description": "True when upstream/downstream pair satisfies deltaTTarget everywhere.",
+ "type": "boolean"
+ },
+ "minDeltaT": {
+ "description": "Minimum time grading margin across [ikMin, ikMax] in seconds (s).",
+ "type": "number"
+ },
+ "minMarginS": {
+ "description": "Minimum chronometric selectivity margin alias in seconds (s).",
+ "type": "number"
+ },
+ "status": {
+ "description": "Overall pair selectivity verdict (\"SELECTIVE\" or non-selective state).",
+ "type": "string"
+ }
+ },
+ "type": "object"
+ },
+ "homopolarAnalysis": {
+ "additionalProperties": true,
+ "description": "Zero-sequence capacitive sum and per-feeder 51N/67N selectivity summary.",
+ "properties": {
+ "busId": {
+ "description": "Evaluated MV busbar identifier for earth-fault grading.",
+ "type": "string"
+ },
+ "totalThreeIc0Amp": {
+ "description": "Total busbar zero-sequence capacitive current 3Ic0 in amperes (A).",
+ "type": "number"
+ }
+ },
+ "type": "object"
+ },
+ "legalNotice": {
+ "description": "Non-substitution intellectual-property banner adapted to the caller permission tier.",
+ "type": "string"
+ },
+ "mode": {
+ "description": "Executed time-current selectivity or homopolar calculation sub-mode.",
+ "type": "string"
+ },
+ "operatingTimeSec": {
+ "description": "Evaluated single-point tripping duration in seconds (s) for curve modes.",
+ "type": "number"
+ },
+ "singleCurve": {
+ "additionalProperties": true,
+ "description": "Single-relay operating time evaluation at the requested current.",
+ "properties": {
+ "currentA": {
+ "description": "Evaluated primary test current in amperes (A).",
+ "type": "number"
+ },
+ "operatingTimeSec": {
+ "description": "Computed relay trip operating time in seconds (s).",
+ "type": "number"
+ },
+ "trips": {
+ "description": "True when the test current exceeds pickup and initiates tripping.",
+ "type": "boolean"
+ }
+ },
+ "type": "object"
+ },
+ "solvedTms": {
+ "description": "Analytically inverted Time Multiplier Setting TMS matching targetTimeS.",
+ "type": "number"
+ }
+ },
+ "type": "object"
+}