addedInput schema / properties / cosPhiRated / default
Added value: +0.8
changedInput schema / properties / cosPhiRated / description
Previous value: -"Facteur de puissance nominal alternateur."New value: +"Synchronous generator rated lagging power factor cos(phi) (0.1..1.0, defaults to 0.8)."
addedInput schema / properties / cosPhiRated / maximum
Added value: +1
addedInput schema / properties / cosPhiRated / minimum
Added value: +0.1
addedInput schema / properties / dipFaultType / default
Added value: +"SLG"
changedInput schema / properties / dipFaultType / description
Previous value: -"Type de défaut pour propagation creux."New value: +"Upstream fault type for voltage-dip propagation (\"SLG\", \"2L\", \"3L\", defaults to \"SLG\")."
changedInput schema / properties / dipFaultType / enum
Previous value: -[
- "SLG",
- "2L",
- "3L"
-]New value: +[
+ "SLG",
+ "2L",
+ "3L",
+ "LL",
+ "LLG",
+ "3PH"
+]
addedInput schema / properties / energizedStepsN / default
Added value: +3
changedInput schema / properties / energizedStepsN / description
Previous value: -"Nombre de gradins déjà sous tension."New value: +"Number of capacitor bank steps already energized in parallel (1..10, defaults to 3)."
addedInput schema / properties / energizedStepsN / maximum
Added value: +10
addedInput schema / properties / energizedStepsN / minimum
Added value: +1
changedInput schema / properties / htaCableKm / description
Previous value: -"Longueur totale cumulée câbles XLPE HTA (km)."New value: +"Total MV XLPE underground cable route length in km (0..200 km; defaults to preset length)."
addedInput schema / properties / htaCableKm / maximum
Added value: +200
addedInput schema / properties / htaCableKm / minimum
Added value: +0
changedInput schema / properties / htbCableKm / description
Previous value: -"Longueur totale cumulée câbles XLPE HTB (km)."New value: +"Total HV XLPE underground cable route length in km (0..100 km; defaults to preset length)."
addedInput schema / properties / htbCableKm / maximum
Added value: +100
addedInput schema / properties / htbCableKm / minimum
Added value: +0
addedInput schema / properties / lChocUh / default
Added value: +50
changedInput schema / properties / lChocUh / description
Previous value: -"Inductance self de choc L_choc (µH)."New value: +"Current-limiting air-core damping reactor inductance L_choc in uH (0..1000 uH, defaults to 50 uH)."
addedInput schema / properties / lChocUh / maximum
Added value: +1000
addedInput schema / properties / lChocUh / minimum
Added value: +0
addedInput schema / properties / mode / default
Added value: +"varmetric"
changedInput schema / properties / mode / description
Previous value: -"Mode d’analyse varmétrique / P-Q (défaut: complet)."New value: +"Reactive balance, transient switching, or P-Q study mode (defaults to \"varmetric\")."
addedInput schema / properties / pOpPu / default
Added value: +0.8
changedInput schema / properties / pOpPu / description
Previous value: -"Puissance active point de fonctionnement P_op (p.u.)."New value: +"Generator operating active power P_op in per-unit of Sn (0..1.0 pu, defaults to 0.8 pu)."
addedInput schema / properties / pOpPu / maximum
Added value: +1
addedInput schema / properties / pOpPu / minimum
Added value: +0
addedInput schema / properties / presetId / default
Added value: +"dc_225_76mw_sel"
changedInput schema / properties / presetId / description
Previous value: -"Preset site (dc_225_76mw_sel, indus_20kv_4x5mvar, cogen_20kv_12mva, rfg_d_225kv_120mva)."New value: +"Reactive substation compensation plant preset identifier (defaults to \"dc_225_76mw_sel\")."
addedInput schema / properties / qOpPu / default
Added value: +-0.34
changedInput schema / properties / qOpPu / description
Previous value: -"Puissance réactive point de fonctionnement Q_op (p.u.)."New value: +"Generator operating reactive power Q_op in per-unit of Sn (-1.2..1.0 pu, defaults to -0.34 pu)."
addedInput schema / properties / qOpPu / maximum
Added value: +1
addedInput schema / properties / qOpPu / minimum
Added value: +-1.2
addedInput schema / properties / selAutoMode / default
Added value: +true
changedInput schema / properties / selAutoMode / description
Previous value: -"Mode SEL automatique anti-pénalité heures creuses."New value: +"Enable automatic shunt reactor switching to avoid capacitive export penalties (defaults to true)."
changedInput schema / properties / selReactorMvar / description
Previous value: -"Puissance réactance shunt SEL (Mvar)."New value: +"Shunt compensation reactor reactive rating in Mvar (0..200 Mvar; defaults to preset rating)."
addedInput schema / properties / selReactorMvar / maximum
Added value: +200
addedInput schema / properties / selReactorMvar / minimum
Added value: +0
addedInput schema / properties / snMva / default
Added value: +12
changedInput schema / properties / snMva / description
Previous value: -"Puissance apparente alternateur (MVA)."New value: +"Synchronous generator rated apparent power Sn in MVA (0.5..1000 MVA, defaults to 12 MVA)."
addedInput schema / properties / snMva / maximum
Added value: +1000
addedInput schema / properties / snMva / minimum
Added value: +0.5
addedInput schema / properties / stepMvar / default
Added value: +5
changedInput schema / properties / stepMvar / description
Previous value: -"Puissance unitaire d’un gradin batterie (Mvar)."New value: +"Unit reactive power rating per capacitor step in Mvar (0.05..100 Mvar, defaults to 5 Mvar)."
addedInput schema / properties / stepMvar / maximum
Added value: +100
addedInput schema / properties / stepMvar / minimum
Added value: +0.05
addedInput schema / properties / transformerCoupling / default
Added value: +"Dyn11_Dyn11"
changedInput schema / properties / transformerCoupling / description
Previous value: -"Chaîne de couplage transformateurs."New value: +"Transformer winding coupling chain for dip propagation (defaults to \"Dyn11_Dyn11\")."
removedInput schema / properties / transformerCoupling / enum
Removed value: -[
- "Dyn11_Dyn11",
- "Dyn11_Yyn0",
- "Direct"
-]
addedInput schema / properties / unKv / default
Added value: +20
changedInput schema / properties / unKv / description
Previous value: -"Tension jeu de barres batteries HTA (kV)."New value: +"MV capacitor bank busbar nominal voltage Un in kV (0.38..420 kV, defaults to 20 kV)."
addedInput schema / properties / unKv / maximum
Added value: +420
addedInput schema / properties / unKv / minimum
Added value: +0.38
changedOutput schema / (root)
Previous value: -nullNew value: +{
+ "additionalProperties": true,
+ "description": "Reactive varmetric balance, capacitor transient, and generator P-Q report with calculationTrace and legalNotice.",
+ "properties": {
+ "calculationTrace": {
+ "additionalProperties": true,
+ "description": "Transparent audit trail listing inputs, defaults, SI formulas, constants, and engineering assumptions.",
+ "properties": {
+ "defaultsApplied": {
+ "additionalProperties": true,
+ "description": "Default SI parameters injected when optional inputs are omitted.",
+ "properties": {},
+ "type": "object"
+ },
+ "engineeringAssumptions": {
+ "description": "Boundary conditions assumed by the calculation engine.",
+ "items": {
+ "description": "Validity assumption constraining interpretation.",
+ "type": "string"
+ },
+ "type": "array"
+ },
+ "formulasAndConstants": {
+ "additionalProperties": true,
+ "description": "Mathematical formulas and constants applied during evaluation.",
+ "properties": {
+ "constants": {
+ "additionalProperties": true,
+ "description": "Physical constants and conversion coefficients in SI units.",
+ "properties": {},
+ "type": "object"
+ },
+ "formulas": {
+ "description": "Evaluated physical formulas.",
+ "items": {
+ "description": "Symbolic SI physics equation.",
+ "type": "string"
+ },
+ "type": "array"
+ }
+ },
+ "type": "object"
+ },
+ "inputsProvided": {
+ "additionalProperties": true,
+ "description": "Caller-supplied parameters normalized before execution.",
+ "properties": {},
+ "type": "object"
+ },
+ "mode": {
+ "description": "Executed physics calculation sub-mode for this call.",
+ "type": "string"
+ },
+ "physicalPrinciples": {
+ "description": "Ordered physical principles backing the solver.",
+ "items": {
+ "description": "Physical principle governing the analytical model.",
+ "type": "string"
+ },
+ "type": "array"
+ },
+ "tool": {
+ "description": "Canonical MCP tool identifier recorded by the calculation tracer.",
+ "type": "string"
+ }
+ },
+ "type": "object"
+ },
+ "capacitorSwitching": {
+ "additionalProperties": true,
+ "description": "Back-to-back capacitor step switching transient and L_choc sizing report.",
+ "properties": {
+ "bareBackToBack": {
+ "additionalProperties": true,
+ "description": "Unmitigated back-to-back switching metrics.",
+ "properties": {
+ "compliant": {
+ "description": "True when unmitigated transient meets breaker duty.",
+ "type": "boolean"
+ },
+ "fHz": {
+ "description": "Unmitigated transient inrush frequency in Hz.",
+ "type": "number"
+ },
+ "iPeakKa": {
+ "description": "Unmitigated back-to-back inrush peak in kA.",
+ "type": "number"
+ }
+ },
+ "type": "object"
+ },
+ "mitigatedBackToBack": {
+ "additionalProperties": true,
+ "description": "Series-reactor mitigated switching transient metrics.",
+ "properties": {
+ "allCompliant": {
+ "description": "True if peak, frequency, and di/dt limits pass.",
+ "type": "boolean"
+ },
+ "fHz": {
+ "description": "Mitigated transient inrush frequency in Hz.",
+ "type": "number"
+ },
+ "iPeakKa": {
+ "description": "Mitigated back-to-back inrush peak in kA.",
+ "type": "number"
+ },
+ "lChocUh": {
+ "description": "Applied damping reactor inductance in uH.",
+ "type": "number"
+ }
+ },
+ "type": "object"
+ },
+ "sizingAndDischarge": {
+ "additionalProperties": true,
+ "description": "Damping reactor and discharge resistor sizing.",
+ "properties": {
+ "rdMaxMohm": {
+ "description": "Maximum allowable discharge resistor in megaohms.",
+ "type": "number"
+ },
+ "recommendedLChocUh": {
+ "description": "Minimum recommended standard L_choc reactor in uH.",
+ "type": "number"
+ }
+ },
+ "type": "object"
+ },
+ "stepMvar": {
+ "description": "Switched capacitor bank step size in Mvar.",
+ "type": "number"
+ },
+ "unKv": {
+ "description": "Evaluated capacitor busbar voltage in kV.",
+ "type": "number"
+ }
+ },
+ "type": "object"
+ },
+ "generatorPq": {
+ "additionalProperties": true,
+ "description": "Synchronous generator P-Q capability envelope and ANSI 40 mho offset relay circles.",
+ "properties": {
+ "cosPhiRated": {
+ "description": "Generator rated lagging power factor.",
+ "type": "number"
+ },
+ "operatingPoint": {
+ "additionalProperties": true,
+ "description": "Generator operating point versus capability and ANSI 40 circles.",
+ "properties": {
+ "inAnsi40Z1": {
+ "description": "True if inside ANSI 40 Zone 1 circle.",
+ "type": "boolean"
+ },
+ "inSslLimit": {
+ "description": "True if inside steady-state stability limit.",
+ "type": "boolean"
+ },
+ "inStatorLimit": {
+ "description": "True if inside stator thermal circle.",
+ "type": "boolean"
+ },
+ "pOpMw": {
+ "description": "Operating active power in MW.",
+ "type": "number"
+ },
+ "qOpMvar": {
+ "description": "Operating reactive power in Mvar.",
+ "type": "number"
+ }
+ },
+ "type": "object"
+ },
+ "snMva": {
+ "description": "Generator rated apparent power in MVA.",
+ "type": "number"
+ },
+ "underExcHierarchyValid": {
+ "description": "True when UEL, stability boundary, and ANSI 40 zones are safely ordered.",
+ "type": "boolean"
+ }
+ },
+ "type": "object"
+ },
+ "legalNotice": {
+ "description": "Non-substitution intellectual-property banner adapted to the caller permission tier.",
+ "type": "string"
+ },
+ "mode": {
+ "description": "Executed varmetric, capacitor switching, or P-Q study mode.",
+ "type": "string"
+ },
+ "reactiveBalance": {
+ "additionalProperties": true,
+ "description": "Site 10-100% reactive balance, OLTC coordination, and voltage-dip audit.",
+ "properties": {
+ "dipPropagation": {
+ "additionalProperties": true,
+ "description": "Transformer voltage-dip propagation audit.",
+ "properties": {
+ "minResidualPu": {
+ "description": "Minimum retained phase voltage after transformer transfer in pu.",
+ "type": "number"
+ },
+ "passesItic": {
+ "description": "True if dip meets data-processing equipment ride-through envelope.",
+ "type": "boolean"
+ },
+ "passesSemiF47": {
+ "description": "True if dip meets sensitive industrial equipment ride-through envelope.",
+ "type": "boolean"
+ }
+ },
+ "type": "object"
+ },
+ "presetId": {
+ "description": "Resolved reactive compensation plant preset ID.",
+ "type": "string"
+ },
+ "qcTotalMvar": {
+ "description": "Total capacitive reactive generation from HV/MV cables in Mvar.",
+ "type": "number"
+ },
+ "sweep": {
+ "description": "10-100% load sweep reactive power table.",
+ "items": {
+ "additionalProperties": true,
+ "description": "Load-step varmetric balance point.",
+ "properties": {
+ "loadPct": {
+ "description": "Load percentage (10-100%).",
+ "type": "number"
+ },
+ "qPccAutoMvar": {
+ "description": "Net PCC reactive power in Mvar.",
+ "type": "number"
+ },
+ "tanPhiAuto": {
+ "description": "Resulting PCC power-factor tangent tan(phi) under auto control.",
+ "type": "number"
+ }
+ },
+ "type": "object"
+ },
+ "type": "array"
+ },
+ "turpeImpact": {
+ "additionalProperties": true,
+ "description": "Utility tariff reactive power-factor envelope check.",
+ "properties": {
+ "allAutoPointsCompliant": {
+ "description": "True if all 10-100% load points satisfy reactive thresholds.",
+ "type": "boolean"
+ },
+ "selAutoMode": {
+ "description": "True if automatic shunt switching is enabled.",
+ "type": "boolean"
+ }
+ },
+ "type": "object"
+ }
+ },
+ "type": "object"
+ }
+ },
+ "type": "object"
+}