addedInput schema / properties / ansi21Distance / additionalProperties
Added value: +true
changedInput schema / properties / ansi21Distance / description
Previous value: -"Paramètres protection de distance ANSI 21 (Z1/Z2/Z3/Z4, arc Van Warrington, load encroachment)."New value: +"HV distance protection zones Z1-Z4, arc resistance, and load encroachment parameters."
addedInput schema / properties / ansi21Distance / properties
Added value: +{}
addedInput schema / properties / ansi49Thermal / additionalProperties
Added value: +true
changedInput schema / properties / ansi49Thermal / description
Previous value: -"Paramètres image thermique ANSI 49 (modèle analytique) : courant nominal, facteur k, charge, pré-charge, constante tau."New value: +"First-order thermal overload memory function 49 parameters (rated A, k factor, load A, tau in min)."
addedInput schema / properties / ansi49Thermal / properties
Added value: +{}
addedInput schema / properties / ansi87tDiff / additionalProperties
Added value: +true
changedInput schema / properties / ansi87tDiff / description
Previous value: -"Paramètres différentielle transformateur ANSI 87T + prises OLTC."New value: +"Transformer differential 87T bias slope and extreme OLTC tap-position stability inputs."
addedInput schema / properties / ansi87tDiff / properties
Added value: +{}
addedInput schema / properties / busbarBpn / additionalProperties
Added value: +true
changedInput schema / properties / busbarBpn / description
Previous value: -"Audit optionnel BPN / limites capacitives 3Ic et découplage jeux de barres."New value: +"Optional neutral earthing reactor BPN capacitive ceiling 3Ic0 and bus-coupler decoupling inputs."
addedInput schema / properties / busbarBpn / properties
Added value: +{}
addedInput schema / properties / ccfDirectional67Q / additionalProperties
Added value: +true
changedInput schema / properties / ccfDirectional67Q / description
Previous value: -"Audit optionnel comparatif directionnel 67N vs 67Q (V2/I2) vs Z2 sur défauts doubles CCF."New value: +"Optional comparative directional 67N versus negative-sequence 67Q/Z2 cross-country fault inputs."
addedInput schema / properties / ccfDirectional67Q / properties
Added value: +{}
addedInput schema / properties / chronometricGrading / additionalProperties
Added value: +true
changedInput schema / properties / chronometricGrading / description
Previous value: -"Paramètres du budget chronométrique ΔT et sélectivité ampèremétrique."New value: +"Chronometric delta-t time budget and amperemetric pickup sensitivity parameters."
addedInput schema / properties / chronometricGrading / properties
Added value: +{}
addedInput schema / properties / ctRealBurdenAlf / additionalProperties
Added value: +true
changedInput schema / properties / ctRealBurdenAlf / description
Previous value: -"Audit optionnel charge filerie réelle 75 °C, FLP’ réel, K_td et I_lin,max (ABB/CT194)."New value: +"Optional 75 C real wiring burden effective ALF', transient Ktd, and linear limit I_lin,max audit inputs."
addedInput schema / properties / ctRealBurdenAlf / properties
Added value: +{}
addedInput schema / properties / ctSaturation / additionalProperties
Added value: +true
changedInput schema / properties / ctSaturation / description
Previous value: -"Paramètres TC & court-circuit pour calcul Kssc / Ktd (modèle analytique)."New value: +"Current transformer nameplate and fault parameters for Kssc and transient Ktd flux saturation audit."
addedInput schema / properties / ctSaturation / properties
Added value: +{}
addedInput schema / properties / ctVtCoherence / additionalProperties
Added value: +true
changedInput schema / properties / ctVtCoherence / description
Previous value: -"Audit optionnel cohérence TC/TP, polarité P1/S1, 59N triangle ouvert et Holmgreen."New value: +"Optional CT/VT polarity P1/S1, open-delta 59N supervision, and 3-CT residual coherence inputs."
addedInput schema / properties / ctVtCoherence / properties
Added value: +{}
addedInput schema / properties / downstreamSmallCable / additionalProperties
Added value: +true
changedInput schema / properties / downstreamSmallCable / description
Previous value: -"Audit optionnel tenue adiabatique petit câble aval et cellule PASA."New value: +"Optional downstream small-section cable adiabatic thermal withstand and ATS transfer-lockout inputs."
addedInput schema / properties / downstreamSmallCable / properties
Added value: +{}
removedInput schema / properties / enedisDecoupling
Removed value: -{
- "description": "Audit optionnel découplage HTA/BT Enedis-NOI-RES_13E (B.1, H.1..H.5, SR.0..SR.3).",
- "type": "object"
-}
addedInput schema / properties / faultSplitting3Ct / additionalProperties
Added value: +true
changedInput schema / properties / faultSplitting3Ct / description
Previous value: -"Audit optionnel division de courant arrivées parallèles et saturation 3TC à l’enclenchement."New value: +"Optional parallel incomer fault splitting and simultaneous energization 3-CT saturation inputs."
addedInput schema / properties / faultSplitting3Ct / properties
Added value: +{}
addedInput schema / properties / frequencyHz / default
Added value: +50
changedInput schema / properties / frequencyHz / description
Previous value: -"Fréquence nominale réseau en Hz (défaut: 50)."New value: +"Nominal network operating frequency in hertz (50 or 60 Hz, defaults to 50 Hz)."
addedInput schema / properties / frequencyHz / maximum
Added value: +100
addedInput schema / properties / frequencyHz / minimum
Added value: +10
addedInput schema / properties / generatorDecay / additionalProperties
Added value: +true
changedInput schema / properties / generatorDecay / description
Previous value: -"Audit optionnel décroissance subtransitoire/permanente groupes électrogènes & ANSI 51V."New value: +"Optional standby generator subtransient fault-current decay and voltage-restrained 51V audit inputs."
addedInput schema / properties / generatorDecay / properties
Added value: +{}
addedInput schema / properties / gridDecoupling
Added value: +{
+ "additionalProperties": true,
+ "description": "Optional utility MV/LV interface decoupling protection thresholds (voltage, frequency, and rate-of-change stages).",
+ "properties": {},
+ "type": "object"
+}
addedInput schema / properties / lang / default
Added value: +"fr"
changedInput schema / properties / lang / description
Previous value: -"Langue de synthèse (fr | en)."New value: +"Localization language code for labels and diagnostics (\"fr\" or \"en\", defaults to \"fr\")."
addedInput schema / properties / logicSelectivitySl / additionalProperties
Added value: +true
changedInput schema / properties / logicSelectivitySl / description
Previous value: -"Audit optionnel cascade Sélectivité Logique SL / ZSI CT002 (gain I²t, watchdog, aiguillage 67)."New value: +"Optional zone-selective interlocking cascade timing, I2t thermal reduction, and watchdog inputs."
addedInput schema / properties / logicSelectivitySl / properties
Added value: +{}
addedInput schema / properties / mode / default
Added value: +"all"
changedInput schema / properties / mode / description
Previous value: -"Sous-audit ciblé optionnel (défaut: full)."New value: +"Optional protection physics audit sub-mode (full, all, chronometric, genset_decay, mv_lv_secondary, small_cable_pasa, busbar_bpn, ct_vt_coherence, mv_loop, pwh1_compensated, ccf_67q_z2, grid_decoupling, xfmr_87t_64ref, mv_fuse_qm, mv_motor_plan, logic_selectivity_sl, ct_real_burden_alf; defaults to \"all\")."
removedInput schema / properties / mode / enum
Removed value: -[
- "full",
- "chronometric",
- "genset_decay",
- "mv_lv_secondary",
- "small_cable_pasa",
- "busbar_bpn",
- "ct_vt_coherence",
- "mv_loop",
- "pwh1_compensated",
- "ccf_67q_z2",
- "grid_decoupling",
- "enedis_decoupling",
- "xfmr_87t_64ref",
- "mv_fuse_qm",
- "mv_motor_plan",
- "logic_selectivity_sl",
- "ct_real_burden_alf"
-]
addedInput schema / properties / mvFuseQm / additionalProperties
Added value: +true
changedInput schema / properties / mvFuseQm / description
Previous value: -"Audit optionnel coordination fusible Fusarc CF + interrupteur QM (I_transfert, I3, inrush)."New value: +"Optional MV current-limiting fuse and load-break switch transfer coordination inputs (I_transfer, I3, and inrush)."
addedInput schema / properties / mvFuseQm / properties
Added value: +{}
addedInput schema / properties / mvLvTransformer / additionalProperties
Added value: +true
changedInput schema / properties / mvLvTransformer / description
Previous value: -"Audit optionnel secondaire BT transformateur HTA/BT & réenclenchement / inrush H2."New value: +"Optional MV/LV secondary clearing-time, H2 restraint, and cumulative re-energization inrush inputs."
addedInput schema / properties / mvLvTransformer / properties
Added value: +{}
addedInput schema / properties / mvMotorPlan / additionalProperties
Added value: +true
changedInput schema / properties / mvMotorPlan / description
Previous value: -"Audit optionnel plan de protection moteur HTA (49/48/51LR/50/46/37/66/51N)."New value: +"Optional MV motor protection plan verification inputs (49, 48, 51LR, 50, 46, 37, 66, and 51N)."
addedInput schema / properties / mvMotorPlan / properties
Added value: +{}
addedInput schema / properties / pwh1Compensated / additionalProperties
Added value: +true
changedInput schema / properties / pwh1Compensated / description
Previous value: -"Audit optionnel wattmétrique PWH1 (32N) et neutre compensé bobine Petersen (B61-221)."New value: +"Optional wattmetric earth-fault 32N and compensated Petersen coil neutral regime audit inputs."
addedInput schema / properties / pwh1Compensated / properties
Added value: +{}
addedInput schema / properties / xfmr87t64Ref / additionalProperties
Added value: +true
changedInput schema / properties / xfmr87t64Ref / description
Previous value: -"Audit optionnel 87T Is1_min exact, blocage Low-H2 ultrasaturation & 64REF haute impédance / Metrosil."New value: +"Optional 87T minimum pickup Is1_min, low-H2 ultrasaturation block, and high-impedance 64REF voltage varistor inputs."
addedInput schema / properties / xfmr87t64Ref / properties
Added value: +{}
changedOutput schema / (root)
Previous value: -nullNew value: +{
+ "additionalProperties": true,
+ "description": "Protection plan physical limits audit payload with sub-module results, trace, and legal notice.",
+ "properties": {
+ "ansi21Distance": {
+ "additionalProperties": true,
+ "description": "Distance protection reach, kZ0 residual factor, and load-encroachment check.",
+ "properties": {
+ "lineSummary": {
+ "additionalProperties": true,
+ "description": "Primary and secondary positive-sequence line impedance summary.",
+ "properties": {},
+ "type": "object"
+ },
+ "zones": {
+ "description": "Computed Z1-Z4 distance zones.",
+ "items": {
+ "additionalProperties": true,
+ "description": "Distance protection zone reach and timer record.",
+ "properties": {},
+ "type": "object"
+ },
+ "type": "array"
+ }
+ },
+ "type": "object"
+ },
+ "ansi49Thermal": {
+ "additionalProperties": true,
+ "description": "Thermal replica function 49 steady-state temperature and time-to-trip audit.",
+ "properties": {
+ "status": {
+ "description": "Thermal overload verdict (\"OK\", \"ALARM\", or \"TRIP\").",
+ "type": "string"
+ },
+ "steadyStateThermalPct": {
+ "description": "Steady-state thermal state percentage relative to trip threshold (%).",
+ "type": "number"
+ },
+ "thermalBaseCurrentA": {
+ "description": "Thermal reference current k * In in amperes (A).",
+ "type": "number"
+ }
+ },
+ "type": "object"
+ },
+ "ansi87tDiff": {
+ "additionalProperties": true,
+ "description": "Transformer differential 87T through-fault and OLTC tap stability result.",
+ "properties": {
+ "allStableUnder085Criterion": {
+ "description": "True when 0.85 * Iop exceeds spurious differential current across all OLTC taps.",
+ "type": "boolean"
+ },
+ "worstTapMismatchPct": {
+ "description": "Worst-case OLTC tap ratio mismatch percentage (%).",
+ "type": "number"
+ }
+ },
+ "type": "object"
+ },
+ "calculationTrace": {
+ "additionalProperties": true,
+ "description": "Transparent audit trail listing inputs, defaults, SI formulas, constants, and engineering assumptions.",
+ "properties": {
+ "defaultsApplied": {
+ "additionalProperties": true,
+ "description": "Default SI parameters injected when optional inputs are omitted.",
+ "properties": {},
+ "type": "object"
+ },
+ "engineeringAssumptions": {
+ "description": "Boundary conditions assumed by the calculation engine.",
+ "items": {
+ "description": "Validity assumption constraining interpretation.",
+ "type": "string"
+ },
+ "type": "array"
+ },
+ "formulasAndConstants": {
+ "additionalProperties": true,
+ "description": "Mathematical formulas and constants applied during evaluation.",
+ "properties": {
+ "constants": {
+ "additionalProperties": true,
+ "description": "Physical constants and conversion coefficients in SI units.",
+ "properties": {},
+ "type": "object"
+ },
+ "formulas": {
+ "description": "Evaluated physical formulas.",
+ "items": {
+ "description": "Symbolic SI physics equation.",
+ "type": "string"
+ },
+ "type": "array"
+ }
+ },
+ "type": "object"
+ },
+ "inputsProvided": {
+ "additionalProperties": true,
+ "description": "Caller-supplied parameters normalized before execution.",
+ "properties": {},
+ "type": "object"
+ },
+ "mode": {
+ "description": "Executed physics calculation sub-mode for this call.",
+ "type": "string"
+ },
+ "physicalPrinciples": {
+ "description": "Ordered physical principles backing the solver.",
+ "items": {
+ "description": "Physical principle governing the analytical model.",
+ "type": "string"
+ },
+ "type": "array"
+ },
+ "tool": {
+ "description": "Canonical MCP tool identifier recorded by the calculation tracer.",
+ "type": "string"
+ }
+ },
+ "type": "object"
+ },
+ "chronometricGrading": {
+ "additionalProperties": true,
+ "description": "Chronometric time-step decomposition and current-grading check.",
+ "properties": {
+ "physicalMinimumMs": {
+ "description": "Minimum physical chronometric delta-t step in milliseconds (ms).",
+ "type": "number"
+ },
+ "recommendedDesignMs": {
+ "description": "Recommended engineering chronometric grading target in milliseconds (ms).",
+ "type": "number"
+ }
+ },
+ "type": "object"
+ },
+ "ctSaturation": {
+ "additionalProperties": true,
+ "description": "Current transformer steady and transient flux saturation assessment.",
+ "properties": {
+ "effectiveAlf": {
+ "description": "Effective accuracy limit factor ALF' under connected burden.",
+ "type": "number"
+ },
+ "kssc": {
+ "description": "Symmetrical short-circuit current factor Kssc = Ik_max / Ipn.",
+ "type": "number"
+ },
+ "ktdTransient": {
+ "description": "Transient DC-offset dimensioning factor Ktd.",
+ "type": "number"
+ },
+ "status": {
+ "description": "CT saturation verdict (\"OK\", \"TRANSIENT_SATURATION_WARNING\", or \"SATURATION_RISK\").",
+ "type": "string"
+ }
+ },
+ "type": "object"
+ },
+ "frequencyHz": {
+ "description": "Evaluated nominal network frequency in hertz (Hz).",
+ "type": "number"
+ },
+ "globalCompliance": {
+ "additionalProperties": true,
+ "description": "Overall compliance scorecards and critical finding counts.",
+ "properties": {
+ "criticalChecks": {
+ "description": "Number of critical non-compliance findings detected.",
+ "type": "integer"
+ },
+ "overallStatus": {
+ "description": "Aggregated plan verdict (\"PASS\", \"WARNING\", or \"NON_COMPLIANT\").",
+ "type": "string"
+ },
+ "passedChecks": {
+ "description": "Number of core protection audits passing physical criteria.",
+ "type": "integer"
+ },
+ "warningChecks": {
+ "description": "Number of core or optional audits raising warnings.",
+ "type": "integer"
+ }
+ },
+ "type": "object"
+ },
+ "lang": {
+ "description": "Resolved localization language code (\"fr\" or \"en\").",
+ "type": "string"
+ },
+ "legalNotice": {
+ "description": "Non-substitution intellectual-property banner adapted to the caller permission tier.",
+ "type": "string"
+ },
+ "mode": {
+ "description": "Executed protection physics audit sub-mode identifier.",
+ "type": "string"
+ }
+ },
+ "type": "object"
+}