Protection Plan Physics and CT Saturation Auditor

sodural_audit_protection_plan_physics
Read-onlyIdempotent

Audit substation protection physical limits: transient CT flux factor Ktd and 75 C wiring burden ALF', chronometric delta-t grading in ms, function 49 thermal trajectories, 87T OLTC tap stability, ANSI 21 encroachment, genset decay, Petersen 32N, 67Q cross-country faults, utility decoupling, fuse-switch transfer, motor plans, and logic selectivity. When to use: Use this tool when verifying protection-chain physical limits; do NOT use for inverse-time relay curve plotting, HV distance/87T settings, or nonlinear RK4 waveforms (call sodural_calc_selectivity_tcc, sodural_calc_ansi21_87t_hv, or brain_calc_arc_flash_ct_comtrade instead). Behavior: Stateless, deterministic, read-only evaluation with zero side effects (HTTP rate-limited at 120 req/min/IP); invalid argument objects raise JSON-RPC -32602. Defaults to mode="all" at 50 Hz and lang="fr". Returns: mode, frequencyHz, ctSaturation, chronometricGrading, ansi49Thermal, ansi87tDiff, ansi21Distance, globalCompliance, calculationTrace, and legalNotice.

Tool call template

This tool declares no required parameters. Add optional parameters from the input schema as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {},
    "name": "sodural_audit_protection_plan_physics"
  }
}

Input Schema

NameRequiredDescriptionDefault
langNoLocalization language code for labels and diagnostics ("fr" or "en", defaults to "fr").fr
modeNoOptional protection physics audit sub-mode (full, all, chronometric, genset_decay, mv_lv_secondary, small_cable_pasa, busbar_bpn, ct_vt_coherence, mv_loop, pwh1_compensated, ccf_67q_z2, grid_decoupling, xfmr_87t_64ref, mv_fuse_qm, mv_motor_plan, logic_selectivity_sl, ct_real_burden_alf; defaults to "all").all
mvFuseQmNoOptional MV current-limiting fuse and load-break switch transfer coordination inputs (I_transfer, I3, and inrush).
busbarBpnNoOptional neutral earthing reactor BPN capacitive ceiling 3Ic0 and bus-coupler decoupling inputs.
ansi87tDiffNoTransformer differential 87T bias slope and extreme OLTC tap-position stability inputs.
frequencyHzNoNominal network operating frequency in hertz (50 or 60 Hz, defaults to 50 Hz).
mvMotorPlanNoOptional MV motor protection plan verification inputs (49, 48, 51LR, 50, 46, 37, 66, and 51N).
ctSaturationNoCurrent transformer nameplate and fault parameters for Kssc and transient Ktd flux saturation audit.
xfmr87t64RefNoOptional 87T minimum pickup Is1_min, low-H2 ultrasaturation block, and high-impedance 64REF voltage varistor inputs.
ansi49ThermalNoFirst-order thermal overload memory function 49 parameters (rated A, k factor, load A, tau in min).
ctVtCoherenceNoOptional CT/VT polarity P1/S1, open-delta 59N supervision, and 3-CT residual coherence inputs.
ansi21DistanceNoHV distance protection zones Z1-Z4, arc resistance, and load encroachment parameters.
generatorDecayNoOptional standby generator subtransient fault-current decay and voltage-restrained 51V audit inputs.
gridDecouplingNoOptional utility MV/LV interface decoupling protection thresholds (voltage, frequency, and rate-of-change stages).
ctRealBurdenAlfNoOptional 75 C real wiring burden effective ALF', transient Ktd, and linear limit I_lin,max audit inputs.
mvLvTransformerNoOptional MV/LV secondary clearing-time, H2 restraint, and cumulative re-energization inrush inputs.
pwh1CompensatedNoOptional wattmetric earth-fault 32N and compensated Petersen coil neutral regime audit inputs.
ccfDirectional67QNoOptional comparative directional 67N versus negative-sequence 67Q/Z2 cross-country fault inputs.
faultSplitting3CtNoOptional parallel incomer fault splitting and simultaneous energization 3-CT saturation inputs.
logicSelectivitySlNoOptional zone-selective interlocking cascade timing, I2t thermal reduction, and watchdog inputs.
chronometricGradingNoChronometric delta-t time budget and amperemetric pickup sensitivity parameters.
downstreamSmallCableNoOptional downstream small-section cable adiabatic thermal withstand and ATS transfer-lockout inputs.

Output Schema

NameRequiredDescriptionDefault
langNoResolved localization language code ("fr" or "en").
modeNoExecuted protection physics audit sub-mode identifier.
ansi87tDiffNoTransformer differential 87T through-fault and OLTC tap stability result.
frequencyHzNoEvaluated nominal network frequency in hertz (Hz).
legalNoticeNoNon-substitution intellectual-property banner adapted to the caller permission tier.
ctSaturationNoCurrent transformer steady and transient flux saturation assessment.
ansi49ThermalNoThermal replica function 49 steady-state temperature and time-to-trip audit.
ansi21DistanceNoDistance protection reach, kZ0 residual factor, and load-encroachment check.
calculationTraceNoTransparent audit trail listing inputs, defaults, SI formulas, constants, and engineering assumptions.
globalComplianceNoOverall compliance scorecards and critical finding counts.
chronometricGradingNoChronometric time-step decomposition and current-grading check.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Changed66 schema fields changed
    • addedInput schema / properties / ansi21Distance / additionalProperties
      Added value: +true
    • changedInput schema / properties / ansi21Distance / description
      Previous value: -"Paramètres protection de distance ANSI 21 (Z1/Z2/Z3/Z4, arc Van Warrington, load encroachment)."New value: +"HV distance protection zones Z1-Z4, arc resistance, and load encroachment parameters."
    • addedInput schema / properties / ansi21Distance / properties
      Added value: +{}
    • addedInput schema / properties / ansi49Thermal / additionalProperties
      Added value: +true
    • changedInput schema / properties / ansi49Thermal / description
      Previous value: -"Paramètres image thermique ANSI 49 (modèle analytique) : courant nominal, facteur k, charge, pré-charge, constante tau."New value: +"First-order thermal overload memory function 49 parameters (rated A, k factor, load A, tau in min)."
    • addedInput schema / properties / ansi49Thermal / properties
      Added value: +{}
    • addedInput schema / properties / ansi87tDiff / additionalProperties
      Added value: +true
    • changedInput schema / properties / ansi87tDiff / description
      Previous value: -"Paramètres différentielle transformateur ANSI 87T + prises OLTC."New value: +"Transformer differential 87T bias slope and extreme OLTC tap-position stability inputs."
    • addedInput schema / properties / ansi87tDiff / properties
      Added value: +{}
    • addedInput schema / properties / busbarBpn / additionalProperties
      Added value: +true
    • changedInput schema / properties / busbarBpn / description
      Previous value: -"Audit optionnel BPN / limites capacitives 3Ic et découplage jeux de barres."New value: +"Optional neutral earthing reactor BPN capacitive ceiling 3Ic0 and bus-coupler decoupling inputs."
    • addedInput schema / properties / busbarBpn / properties
      Added value: +{}
    • addedInput schema / properties / ccfDirectional67Q / additionalProperties
      Added value: +true
    • changedInput schema / properties / ccfDirectional67Q / description
      Previous value: -"Audit optionnel comparatif directionnel 67N vs 67Q (V2/I2) vs Z2 sur défauts doubles CCF."New value: +"Optional comparative directional 67N versus negative-sequence 67Q/Z2 cross-country fault inputs."
    • addedInput schema / properties / ccfDirectional67Q / properties
      Added value: +{}
    • addedInput schema / properties / chronometricGrading / additionalProperties
      Added value: +true
    • changedInput schema / properties / chronometricGrading / description
      Previous value: -"Paramètres du budget chronométrique ΔT et sélectivité ampèremétrique."New value: +"Chronometric delta-t time budget and amperemetric pickup sensitivity parameters."
    • addedInput schema / properties / chronometricGrading / properties
      Added value: +{}
    • addedInput schema / properties / ctRealBurdenAlf / additionalProperties
      Added value: +true
    • changedInput schema / properties / ctRealBurdenAlf / description
      Previous value: -"Audit optionnel charge filerie réelle 75 °C, FLP’ réel, K_td et I_lin,max (ABB/CT194)."New value: +"Optional 75 C real wiring burden effective ALF', transient Ktd, and linear limit I_lin,max audit inputs."
    • addedInput schema / properties / ctRealBurdenAlf / properties
      Added value: +{}
    • addedInput schema / properties / ctSaturation / additionalProperties
      Added value: +true
    • changedInput schema / properties / ctSaturation / description
      Previous value: -"Paramètres TC & court-circuit pour calcul Kssc / Ktd (modèle analytique)."New value: +"Current transformer nameplate and fault parameters for Kssc and transient Ktd flux saturation audit."
    • addedInput schema / properties / ctSaturation / properties
      Added value: +{}
    • addedInput schema / properties / ctVtCoherence / additionalProperties
      Added value: +true
    • changedInput schema / properties / ctVtCoherence / description
      Previous value: -"Audit optionnel cohérence TC/TP, polarité P1/S1, 59N triangle ouvert et Holmgreen."New value: +"Optional CT/VT polarity P1/S1, open-delta 59N supervision, and 3-CT residual coherence inputs."
    • addedInput schema / properties / ctVtCoherence / properties
      Added value: +{}
    • addedInput schema / properties / downstreamSmallCable / additionalProperties
      Added value: +true
    • changedInput schema / properties / downstreamSmallCable / description
      Previous value: -"Audit optionnel tenue adiabatique petit câble aval et cellule PASA."New value: +"Optional downstream small-section cable adiabatic thermal withstand and ATS transfer-lockout inputs."
    • addedInput schema / properties / downstreamSmallCable / properties
      Added value: +{}
    • removedInput schema / properties / enedisDecoupling
      Removed value: -{
      -  "description": "Audit optionnel découplage HTA/BT Enedis-NOI-RES_13E (B.1, H.1..H.5, SR.0..SR.3).",
      -  "type": "object"
      -}
    • addedInput schema / properties / faultSplitting3Ct / additionalProperties
      Added value: +true
    • changedInput schema / properties / faultSplitting3Ct / description
      Previous value: -"Audit optionnel division de courant arrivées parallèles et saturation 3TC à l’enclenchement."New value: +"Optional parallel incomer fault splitting and simultaneous energization 3-CT saturation inputs."
    • addedInput schema / properties / faultSplitting3Ct / properties
      Added value: +{}
    • addedInput schema / properties / frequencyHz / default
      Added value: +50
    • changedInput schema / properties / frequencyHz / description
      Previous value: -"Fréquence nominale réseau en Hz (défaut: 50)."New value: +"Nominal network operating frequency in hertz (50 or 60 Hz, defaults to 50 Hz)."
    • addedInput schema / properties / frequencyHz / maximum
      Added value: +100
    • addedInput schema / properties / frequencyHz / minimum
      Added value: +10
    • addedInput schema / properties / generatorDecay / additionalProperties
      Added value: +true
    • changedInput schema / properties / generatorDecay / description
      Previous value: -"Audit optionnel décroissance subtransitoire/permanente groupes électrogènes & ANSI 51V."New value: +"Optional standby generator subtransient fault-current decay and voltage-restrained 51V audit inputs."
    • addedInput schema / properties / generatorDecay / properties
      Added value: +{}
    • addedInput schema / properties / gridDecoupling
      Added value: +{
      +  "additionalProperties": true,
      +  "description": "Optional utility MV/LV interface decoupling protection thresholds (voltage, frequency, and rate-of-change stages).",
      +  "properties": {},
      +  "type": "object"
      +}
    • addedInput schema / properties / lang / default
      Added value: +"fr"
    • changedInput schema / properties / lang / description
      Previous value: -"Langue de synthèse (fr | en)."New value: +"Localization language code for labels and diagnostics (\"fr\" or \"en\", defaults to \"fr\")."
    • addedInput schema / properties / logicSelectivitySl / additionalProperties
      Added value: +true
    • changedInput schema / properties / logicSelectivitySl / description
      Previous value: -"Audit optionnel cascade Sélectivité Logique SL / ZSI CT002 (gain I²t, watchdog, aiguillage 67)."New value: +"Optional zone-selective interlocking cascade timing, I2t thermal reduction, and watchdog inputs."
    • addedInput schema / properties / logicSelectivitySl / properties
      Added value: +{}
    • addedInput schema / properties / mode / default
      Added value: +"all"
    • changedInput schema / properties / mode / description
      Previous value: -"Sous-audit ciblé optionnel (défaut: full)."New value: +"Optional protection physics audit sub-mode (full, all, chronometric, genset_decay, mv_lv_secondary, small_cable_pasa, busbar_bpn, ct_vt_coherence, mv_loop, pwh1_compensated, ccf_67q_z2, grid_decoupling, xfmr_87t_64ref, mv_fuse_qm, mv_motor_plan, logic_selectivity_sl, ct_real_burden_alf; defaults to \"all\")."
    • removedInput schema / properties / mode / enum
      Removed value: -[
      -  "full",
      -  "chronometric",
      -  "genset_decay",
      -  "mv_lv_secondary",
      -  "small_cable_pasa",
      -  "busbar_bpn",
      -  "ct_vt_coherence",
      -  "mv_loop",
      -  "pwh1_compensated",
      -  "ccf_67q_z2",
      -  "grid_decoupling",
      -  "enedis_decoupling",
      -  "xfmr_87t_64ref",
      -  "mv_fuse_qm",
      -  "mv_motor_plan",
      -  "logic_selectivity_sl",
      -  "ct_real_burden_alf"
      -]
    • addedInput schema / properties / mvFuseQm / additionalProperties
      Added value: +true
    • changedInput schema / properties / mvFuseQm / description
      Previous value: -"Audit optionnel coordination fusible Fusarc CF + interrupteur QM (I_transfert, I3, inrush)."New value: +"Optional MV current-limiting fuse and load-break switch transfer coordination inputs (I_transfer, I3, and inrush)."
    • addedInput schema / properties / mvFuseQm / properties
      Added value: +{}
    • addedInput schema / properties / mvLvTransformer / additionalProperties
      Added value: +true
    • changedInput schema / properties / mvLvTransformer / description
      Previous value: -"Audit optionnel secondaire BT transformateur HTA/BT & réenclenchement / inrush H2."New value: +"Optional MV/LV secondary clearing-time, H2 restraint, and cumulative re-energization inrush inputs."
    • addedInput schema / properties / mvLvTransformer / properties
      Added value: +{}
    • addedInput schema / properties / mvMotorPlan / additionalProperties
      Added value: +true
    • changedInput schema / properties / mvMotorPlan / description
      Previous value: -"Audit optionnel plan de protection moteur HTA (49/48/51LR/50/46/37/66/51N)."New value: +"Optional MV motor protection plan verification inputs (49, 48, 51LR, 50, 46, 37, 66, and 51N)."
    • addedInput schema / properties / mvMotorPlan / properties
      Added value: +{}
    • addedInput schema / properties / pwh1Compensated / additionalProperties
      Added value: +true
    • changedInput schema / properties / pwh1Compensated / description
      Previous value: -"Audit optionnel wattmétrique PWH1 (32N) et neutre compensé bobine Petersen (B61-221)."New value: +"Optional wattmetric earth-fault 32N and compensated Petersen coil neutral regime audit inputs."
    • addedInput schema / properties / pwh1Compensated / properties
      Added value: +{}
    • addedInput schema / properties / xfmr87t64Ref / additionalProperties
      Added value: +true
    • changedInput schema / properties / xfmr87t64Ref / description
      Previous value: -"Audit optionnel 87T Is1_min exact, blocage Low-H2 ultrasaturation & 64REF haute impédance / Metrosil."New value: +"Optional 87T minimum pickup Is1_min, low-H2 ultrasaturation block, and high-impedance 64REF voltage varistor inputs."
    • addedInput schema / properties / xfmr87t64Ref / properties
      Added value: +{}
    • changedOutput schema / (root)
      Previous value: -nullNew value: +{
      +  "additionalProperties": true,
      +  "description": "Protection plan physical limits audit payload with sub-module results, trace, and legal notice.",
      +  "properties": {
      +    "ansi21Distance": {
      +      "additionalProperties": true,
      +      "description": "Distance protection reach, kZ0 residual factor, and load-encroachment check.",
      +      "properties": {
      +        "lineSummary": {
      +          "additionalProperties": true,
      +          "description": "Primary and secondary positive-sequence line impedance summary.",
      +          "properties": {},
      +          "type": "object"
      +        },
      +        "zones": {
      +          "description": "Computed Z1-Z4 distance zones.",
      +          "items": {
      +            "additionalProperties": true,
      +            "description": "Distance protection zone reach and timer record.",
      +            "properties": {},
      +            "type": "object"
      +          },
      +          "type": "array"
      +        }
      +      },
      +      "type": "object"
      +    },
      +    "ansi49Thermal": {
      +      "additionalProperties": true,
      +      "description": "Thermal replica function 49 steady-state temperature and time-to-trip audit.",
      +      "properties": {
      +        "status": {
      +          "description": "Thermal overload verdict (\"OK\", \"ALARM\", or \"TRIP\").",
      +          "type": "string"
      +        },
      +        "steadyStateThermalPct": {
      +          "description": "Steady-state thermal state percentage relative to trip threshold (%).",
      +          "type": "number"
      +        },
      +        "thermalBaseCurrentA": {
      +          "description": "Thermal reference current k * In in amperes (A).",
      +          "type": "number"
      +        }
      +      },
      +      "type": "object"
      +    },
      +    "ansi87tDiff": {
      +      "additionalProperties": true,
      +      "description": "Transformer differential 87T through-fault and OLTC tap stability result.",
      +      "properties": {
      +        "allStableUnder085Criterion": {
      +          "description": "True when 0.85 * Iop exceeds spurious differential current across all OLTC taps.",
      +          "type": "boolean"
      +        },
      +        "worstTapMismatchPct": {
      +          "description": "Worst-case OLTC tap ratio mismatch percentage (%).",
      +          "type": "number"
      +        }
      +      },
      +      "type": "object"
      +    },
      +    "calculationTrace": {
      +      "additionalProperties": true,
      +      "description": "Transparent audit trail listing inputs, defaults, SI formulas, constants, and engineering assumptions.",
      +      "properties": {
      +        "defaultsApplied": {
      +          "additionalProperties": true,
      +          "description": "Default SI parameters injected when optional inputs are omitted.",
      +          "properties": {},
      +          "type": "object"
      +        },
      +        "engineeringAssumptions": {
      +          "description": "Boundary conditions assumed by the calculation engine.",
      +          "items": {
      +            "description": "Validity assumption constraining interpretation.",
      +            "type": "string"
      +          },
      +          "type": "array"
      +        },
      +        "formulasAndConstants": {
      +          "additionalProperties": true,
      +          "description": "Mathematical formulas and constants applied during evaluation.",
      +          "properties": {
      +            "constants": {
      +              "additionalProperties": true,
      +              "description": "Physical constants and conversion coefficients in SI units.",
      +              "properties": {},
      +              "type": "object"
      +            },
      +            "formulas": {
      +              "description": "Evaluated physical formulas.",
      +              "items": {
      +                "description": "Symbolic SI physics equation.",
      +                "type": "string"
      +              },
      +              "type": "array"
      +            }
      +          },
      +          "type": "object"
      +        },
      +        "inputsProvided": {
      +          "additionalProperties": true,
      +          "description": "Caller-supplied parameters normalized before execution.",
      +          "properties": {},
      +          "type": "object"
      +        },
      +        "mode": {
      +          "description": "Executed physics calculation sub-mode for this call.",
      +          "type": "string"
      +        },
      +        "physicalPrinciples": {
      +          "description": "Ordered physical principles backing the solver.",
      +          "items": {
      +            "description": "Physical principle governing the analytical model.",
      +            "type": "string"
      +          },
      +          "type": "array"
      +        },
      +        "tool": {
      +          "description": "Canonical MCP tool identifier recorded by the calculation tracer.",
      +          "type": "string"
      +        }
      +      },
      +      "type": "object"
      +    },
      +    "chronometricGrading": {
      +      "additionalProperties": true,
      +      "description": "Chronometric time-step decomposition and current-grading check.",
      +      "properties": {
      +        "physicalMinimumMs": {
      +          "description": "Minimum physical chronometric delta-t step in milliseconds (ms).",
      +          "type": "number"
      +        },
      +        "recommendedDesignMs": {
      +          "description": "Recommended engineering chronometric grading target in milliseconds (ms).",
      +          "type": "number"
      +        }
      +      },
      +      "type": "object"
      +    },
      +    "ctSaturation": {
      +      "additionalProperties": true,
      +      "description": "Current transformer steady and transient flux saturation assessment.",
      +      "properties": {
      +        "effectiveAlf": {
      +          "description": "Effective accuracy limit factor ALF' under connected burden.",
      +          "type": "number"
      +        },
      +        "kssc": {
      +          "description": "Symmetrical short-circuit current factor Kssc = Ik_max / Ipn.",
      +          "type": "number"
      +        },
      +        "ktdTransient": {
      +          "description": "Transient DC-offset dimensioning factor Ktd.",
      +          "type": "number"
      +        },
      +        "status": {
      +          "description": "CT saturation verdict (\"OK\", \"TRANSIENT_SATURATION_WARNING\", or \"SATURATION_RISK\").",
      +          "type": "string"
      +        }
      +      },
      +      "type": "object"
      +    },
      +    "frequencyHz": {
      +      "description": "Evaluated nominal network frequency in hertz (Hz).",
      +      "type": "number"
      +    },
      +    "globalCompliance": {
      +      "additionalProperties": true,
      +      "description": "Overall compliance scorecards and critical finding counts.",
      +      "properties": {
      +        "criticalChecks": {
      +          "description": "Number of critical non-compliance findings detected.",
      +          "type": "integer"
      +        },
      +        "overallStatus": {
      +          "description": "Aggregated plan verdict (\"PASS\", \"WARNING\", or \"NON_COMPLIANT\").",
      +          "type": "string"
      +        },
      +        "passedChecks": {
      +          "description": "Number of core protection audits passing physical criteria.",
      +          "type": "integer"
      +        },
      +        "warningChecks": {
      +          "description": "Number of core or optional audits raising warnings.",
      +          "type": "integer"
      +        }
      +      },
      +      "type": "object"
      +    },
      +    "lang": {
      +      "description": "Resolved localization language code (\"fr\" or \"en\").",
      +      "type": "string"
      +    },
      +    "legalNotice": {
      +      "description": "Non-substitution intellectual-property banner adapted to the caller permission tier.",
      +      "type": "string"
      +    },
      +    "mode": {
      +      "description": "Executed protection physics audit sub-mode identifier.",
      +      "type": "string"
      +    }
      +  },
      +  "type": "object"
      +}
  2. First observed

TDQS

A4.3/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare read-only, idempotent, non-destructive, closed-world, so the description correctly does not re-argue safety. It adds genuinely non-obvious behavior: HTTP rate limiting at 120 req/min/IP, JSON-RPC -32602 on invalid argument objects, and the mode/frequency/lang defaults. Minor deduction because the "Returns:" field list and the defaults partly restate the output schema and input schema defaults.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness3/5

Is the description appropriately sized, front-loaded, and free of redundancy?

Front-loaded and clearly segmented into purpose, when-to-use, behavior, and returns, which is good structure. However, the opening sentence is a dense wall of enumerated protections ("function 49 ... 87T OLTC ... Petersen 32N, 67Q cross-country faults, utility decoupling, fuse-switch transfer, motor plans...") that largely duplicates the per-parameter schema descriptions, and the "Returns:" list duplicates the output schema.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness5/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a 22-parameter, nested-object, multi-sub-mode auditor this is complete: it states scope, routing, operational constraints, error semantics, defaults, and that a legalNotice plus calculationTrace come back. An agent has everything needed to invoke it correctly and to know when not to.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100% across all 22 parameters, so the schema already carries the semantics for each sub-mode object. The description's parameter-level contribution is limited to restating that mode defaults to "all" and frequency to 50 Hz, which the schema already declares as defaults. Baseline 3 is appropriate.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

States a specific verb and resource ("Audit substation protection physical limits") and then enumerates the concrete physics it covers (Ktd transient flux, 75 C wiring burden ALF', delta-t grading, 49, 87T OLTC, ANSI 21, 32N, 67Q, etc.). It also names the three siblings it is explicitly not, so an agent can distinguish it without opening any schema.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines5/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Contains an explicit "When to use" clause plus a "do NOT use for" exclusion list that routes each excluded case to a named alternative (sodural_calc_selectivity_tcc for inverse-time curves, sodural_calc_ansi21_87t_hv for HV distance/87T settings, brain_calc_arc_flash_ct_comtrade for RK4 waveforms). Nothing about routing is left to inference.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.

Resources