Transformer Ucc Tolerance & Thermal Resistance Calculator
brain_calc_impedance_toleranceCompute transformer short-circuit impedance Ucc manufacturing tolerance bounds, linear copper and aluminum conductor resistance temperature scaling R(theta) between 20 C and operating temperature, and Ik_max/Ik_min branch fault sensitivity multipliers. When to use: Use for single-branch impedance uncertainty bounds and conductor thermal resistance drift; do NOT use for coupled multi-bus Z_bus short-circuit matrices or load flow -- call sodural_solve_topology_whitebox instead. Behavior: Evaluates deterministic, stateless ohmic tolerance bounds with zero external side effects; negative resistances, invalid Ucc values, or tolerance percentages >= 100% raise JSON-RPC -32602, while omitted arguments default to mode="combined", nominalUccPct=12.5%, tolerancePct=10%, snMva=40 MVA, secKv=20 kV, and 90 C copper. Returns: mode, nominalUccPct, minUccPct, maxUccPct, ikMaxMultiplier, ikMinMultiplier, ohmic, cableThermal, calculationTrace, and legalNotice.
Tool call template
This tool declares no required parameters. Add optional parameters from the input schema as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {},
"name": "brain_calc_impedance_tolerance"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| mode | No | Impedance uncertainty sub-study mode (defaults to "combined"). | combined |
| secKv | No | Reference secondary winding line-to-line voltage in kV (defaults to 20 kV). | |
| snMva | No | Transformer rated apparent power Sn in MVA (defaults to 40 MVA). | |
| xrRatio | No | Transformer X/R impedance ratio at nominal tap (defaults to 18). | |
| lengthKm | No | Branch circuit length in km (defaults to 1.0 km). | |
| xOhmPerKm | No | Cable/line positive-sequence inductive reactance in ohm/km (defaults to 0.1). | |
| r20OhmPerKm | No | Conductor DC linear resistance at 20 C in ohm/km (defaults to 0.0754). | |
| nominalIk3Ka | No | Nominal reference 3-phase fault current Ik3 in kA for sensitivity bounds. | |
| tolerancePct | No | Manufacturer percentage tolerance band applied to Ucc (defaults to 10%). | |
| nominalUccPct | No | Nameplate transformer short-circuit impedance voltage Ucc in % (defaults to 12.5%). | |
| measuredUccPct | No | Factory test-report measured Ucc in % for measured_ucc comparison. | |
| operatingTempC | No | Maximum conductor thermal temperature under fault/load in deg C (defaults to 90 C). | |
| conductorMaterial | No | Conductor metal for thermal resistance scaling ("CU" or "AL", defaults to "Cu"). | Cu |
Output Schema
| Name | Required | Description | Default |
|---|---|---|---|
| mode | No | Executed impedance tolerance analysis mode. | |
| ohmic | No | Positive-sequence R(theta) and X ohmic impedance bounds in ohms. | |
| maxUccPct | No | Upper-bound impedance Ucc driving Ik_min in %. | |
| minUccPct | No | Lower-bound impedance Ucc driving Ik_max in %. | |
| legalNotice | No | Informational engineering compliance notice confirming SI physical scope and intellectual property rules. | |
| cableThermal | No | Cold 20 C vs hot operating-temperature resistance scaling details. | |
| nominalUccPct | No | Nominal transformer short-circuit impedance Ucc in %. | |
| ikMaxMultiplier | No | Scaling factor applied to nominal fault current at min Ucc. | |
| ikMinMultiplier | No | Scaling factor applied to nominal fault current at max Ucc. | |
| calculationTrace | No | Transparent audit trail detailing inputs, injected defaults, formulas, constants, principles, and assumptions. |