Skip to main content
Glama

Simple House Planner

Drywall calculator

calculate_drywall
Read-only

Use this when someone asks how many sheets of drywall or plasterboard, screws, tape or joint compound they need. Calculates the drywall for a room: the wall area 2 × (length + width) × height, or a given area, less the doors and windows (36 × 80 in and 36 × 60 in each unless given), plus the ceiling (length × width) when asked; the area with waste (10 % unless given; Georgia-Pacific advises 10 to 15 %); and the sheets, rounded up. Sheets: 4x8, 4x10 and 4x12 ft, and metric boards 600, 1200 and 1250 mm wide; sheetWidth and sheetLength together replace them. With 2 layers, the board area and the screws double. It also returns, for the area to cover and without waste, the joint compound in compoundUnit and the joint tape in millimeters for the outer layer, and the screws for all layers, each the area times its rate per square meter of board. Rates when not given (USG): 9.4 gal of ready-mixed compound per 1,000 sq ft (0.383 l/m²), 370 ft of tape per 1,000 sq ft (1.214 m/m²), and screws 1,000 per 1,000 sq ft on framing 16 in on center (10.76/m²), 850 on framing 24 in on center (9.15/m²), Gypsum Construction Handbook. Other makers give their own rates per square meter, such as about 0.35 to 0.45 kg of powder compound and 1.4 to 1.6 m of tape in Europe and Brazil. Areas are in square meters (1 sq ft = 0.09290304 m²; 1 US gallon = 3.785411784 l).

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "sheet": "<sheet>"
    },
    "name": "calculate_drywall"
  }
}

Input Schema

NameRequiredDescriptionDefault
doorsNoNumber of doors to leave out; none when left out.
sheetYes4x8, 4x10 and 4x12 are US sheets in feet; the others are metric boards, width x length in millimeters.
wallsNoArea to board in square meters, used instead of length, width and height.
wasteNoPercent added for cutting and piecing; 10 when left out.
widthNoRoom width, in millimeters.
heightNoWall height, floor to ceiling, in millimeters.
layersNoLayers of board on each surface, 1 or 2; 1 when left out.
lengthNoRoom length, in millimeters.
ceilingNoTrue to board the ceiling too; needs length and width.
framingNoSpacing of the studs and joists on center, in millimeters: 400 (16 in) or 600 (24 in), which picks USG's screws when screwRate is left out; 400 when left out.
windowsNoNumber of windows to leave out; none when left out.
tapeRateNoJoint tape in millimeters per square meter of board on the walls, such as 1500; USG's 1214 when left out; 0 for boards whose edges need no tape.
doorWidthNoWidth of one door; 914.4 (36 in) when left out, in millimeters.
screwRateNoScrews per square meter of board on the walls, as the board maker gives them, such as 12 on battens 600 mm apart (Chausson); USG's by framing when left out.
doorHeightNoHeight of one door; 2032 (80 in) when left out, in millimeters.
sheetWidthNoBoard width of a size of its own, which replaces the sheet; give sheetLength with it, in millimeters.
sheetLengthNoBoard length of a size of its own, which replaces the sheet; give sheetWidth with it, in millimeters.
windowWidthNoWidth of one window; 914.4 (36 in) when left out, in millimeters.
compoundRateNoJoint compound per square meter of board in compoundUnit, such as 0.35 kg of powder; USG's 0.383 l of ready-mixed compound when left out, which needs compoundUnit l.
compoundUnitNol: liters of ready-mixed compound; kg: kilograms of powder or of ready-mixed compound; l when left out.
windowHeightNoHeight of one window; 1524 (60 in) when left out, in millimeters.
innerScrewRateNoScrews per square meter of the inner of two layers, such as 3 under an outer layer of 8 at 600 mm (Fassa Gypsotech); the outer layer's rate when left out.
ceilingTapeRateNoJoint tape in millimeters per square meter of board on the ceiling, such as 1600 (Chausson); tapeRate when left out.
ceilingScrewRateNoScrews per square meter of board on the ceiling, such as 14 on battens 500 mm apart (Chausson); screwRate when left out.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Added

TDQS

A3.9/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already establish that this is a safe read-only, closed-world calculation, so the bar is lower. The description goes well beyond that, disclosing rounding-up behavior, default waste of 10% (with a 10–15% industry note), doubling under 2 layers, and the source of default rates (USG), which is real behavioral context not present in the annotations.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness2/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The content is largely useful but is delivered as one dense run-on paragraph stitched together with semicolons, mixing inputs, formulas, defaults, and vendor rate tables. The trigger is front-loaded, but the mass of duplicated numeric detail makes it hard to scan and hurts rather than helps rapid tool selection.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

For a 24-parameter tool with no output schema, the description does substantial work explaining what is computed and returned (board area, sheets rounded up, compound in compoundUnit, tape in mm, screws for all layers) and the unit conventions. It stops short of describing the output field shape, but the returned quantities and units are covered well enough to call correctly.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100%, so every parameter is already documented structurally. The description adds some rationale (waste guidance, alternative European/Brazilian rates, 'ceiling needs length and width') but much of its rate/default detail merely restates what the schema fields already say, so it sits at the baseline.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

The opening sentence names the exact resource and outputs (drywall/plasterboard sheets, screws, tape, joint compound) with a clear 'how many X do I need' framing. This is specific enough that an agent can distinguish it from the other calculate_* sizing tools without opening the schema.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines4/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

Explicitly states the triggering question ('Use this when someone asks how many sheets of drywall or plasterboard, screws, tape or joint compound they need'), which gives clear when-to-use context. There is no when-not guidance or named alternative, but the resource is distinctive enough across the calculator family that this is a minor gap.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.

Resources