Use this when someone asks what size of air conditioner, mini split or heater a room needs, in BTU, tons or watts. Calculates the capacity for one room from its floor area. roomAirConditioner: ENERGY STAR's sizing table for room air conditioners (8 ft ceiling): 100 up to 150 sq ft 5,000 BTU/h, 150 up to 250 6,000, 250 up to 300 7,000, 300 up to 350 8,000, 350 up to 400 9,000, 400 up to 450 10,000, 450 up to 550 12,000, 550 up to 700 14,000, 700 up to 1,000 18,000, 1,000 up to 1,200 21,000, 1,200 up to 1,400 23,000, 1,400 up to 1,500 24,000, 1,500 up to 2,000 30,000, 2,000 up to 2,500 34,000; a room under 100 sq ft takes 5,000 and below is true; then −10 % heavily shaded, +10 % very sunny, +600 BTU/h for each person beyond two, +4,000 BTU/h in a kitchen. miniSplit: area in sq ft × 25 BTU/h (Carrier, Trane), and the smallest size of Trane's chart that covers it: 6,000, 9,000, 12,000, 15,000, 18,000, 24,000, 30,000, 36,000, 48,000 or 60,000 BTU/h, up to 2,400 sq ft. heater: an electric room heater at 10 W per sq ft as supplemental heat, or 15 W as the sole heat or in a poorly insulated room (Broan-NuTone). It returns the area in square meters, the base and each adjustment, the capacity in BTU/h, tons (12,000 BTU/h) and kilowatts (1 ton = 3.516853 kW, NIST SP 811), and BTU/h per sq ft. None of these is a load calculation; a system for a whole house is sized with ACCA Manual J and Manual S (IRC M1401.3).

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "system": "<system>"
    },
    "name": "calculate_btu"
  }
}

Input Schema

NameRequiredDescriptionDefault
sunNoRoom air conditioner only: shaded takes 10 % off, sunny adds 10 %; average when left out.
areaNoFloor area in square meters, used instead of length and width.
heatNoHeater only: supplemental (10 W per sq ft) or sole, for the only heat of the room or a poorly insulated room (15 W per sq ft); supplemental when left out.
widthNoRoom width, in millimeters.
lengthNoRoom length, in millimeters.
peopleNoRoom air conditioner only: people who regularly use the room; 600 BTU/h for each beyond two. 2 when left out.
systemYesroomAirConditioner: a window, portable or through-the-wall unit by ENERGY STAR's table; miniSplit: Carrier's and Trane's first estimate; heater: an electric room heater by Broan-NuTone's rule.
kitchenNoRoom air conditioner only: true adds 4,000 BTU/h for a kitchen.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Added

TDQS

A4.7/5.0
Behavior5/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

The annotations already declare a read-only, non-destructive, closed-world calculator. The description adds the sizing methods, assumptions such as an 8 ft ceiling, adjustment rules, unit conversions, return values, and the important limitation that this is not a load calculation.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness3/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The use case is front-loaded, which helps selection. However, the exhaustive BTU table and dense single-paragraph presentation are longer and harder to scan than an agent needs for selection or invocation, even though the details are substantive.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness5/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

This is a complex calculator with 8 parameters and no output schema. The description supplies the calculation methods, assumptions, return units and values, and limitations, which is enough for an agent to call it correctly and interpret the result.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters4/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema coverage is 100%, so the schema already defines each parameter. The description still adds meaningful semantics by giving the ENERGY STAR table, mini-split formula, heater wattage rules, and the specific adjustment values for sun, people, and kitchen.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose5/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description states a specific verb and resource: it calculates cooling or heating capacity for one room in BTU, tons, or watts. It scopes the tool to room air conditioners, mini splits, and heaters, which clearly distinguishes it from whole-house load calculations.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines5/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

The opening sentence gives an explicit when-to-use trigger: someone asking what size air conditioner, mini split, or heater a room needs. It also states an explicit exclusion, saying this is not a load calculation and whole-house sizing requires ACCA Manual J and Manual S.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.

Resources