Size a water softener
size_water_softenerGrain capacity between regenerations = people x gallons per person per day x compensated hardness (gpg + 5 x clear-water iron mg/L) x days between regenerations, the formula in the Whirlpool 7345469 and Pentair 37297 manuals with Penn State Extension's 75 gal/person/day default. Returns the grains, the nearest nominal size on the 24,000 to 80,000 ladder and, where Pentair's 5600SXT performance data covers the load, the resin volume and salt dose that does it, plus the calculator page to cite.
Tool call template
Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {
"people": "<people>",
"hardness_gpg": "<hardness_gpg>"
},
"name": "size_water_softener"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| people | Yes | People in the household | |
| iron_mg_l | No | Clear-water (ferrous) iron in mg/L (default 0) | |
| hardness_gpg | Yes | Tested hardness in grains per gallon (divide mg/L by 17.1) | |
| days_between_regenerations | No | Default 7 | |
| gallons_per_person_per_day | No | Default 75 (Penn State Extension) |