Skip to main content
Glama

MIDAS CIVIL NX tools (MIDAS IT Europe)

Eurocode Section Checker: calculation sheet (Excel)

ec2_export_calc_sheet
Read-only

Use for the EN 1992 Excel calculation sheet. For CS 455 use cs455_export_calc_sheet. The report. Runs the check exactly as ec2_section_check and writes the plugin's calculation sheet (.xlsx in the CS 455 reference format, EN 1992 content, live formulas): one sheet per section - geometry, materials, reinforcement (and tendons with P_m0 / P_m,inf), section properties, and the governing row of each check printed in full (sagging and hogging bending, shear, torsion, SLS stresses, crack width; prestressed / composite: transfer, stage stresses, interface shear, decompression) - plus a Summary sheet with demand, resistance and ratio per check. Returns a download link. Use the same inputs that ec2_describe_section confirmed against the user's drawing. Read-only on the model.

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "sections": "<sections>"
    },
    "name": "ec2_export_calc_sheet"
  }
}

Input Schema

NameRequiredDescriptionDefault
casesNoCombinations (or load cases) by name, optionally with the limit state. Default: every readable combination with the limit state read from its name / CIVIL NX type (frequent ones only when a section is prestressed).
groupNoOr a structure group name.
signsNo
reportNo
screenNoCheck only the governing candidates (force extremes per section and limit state) instead of every row.
stagesNoPrestressed sections: load case name -> girder (self-weight at transfer and on the girder), stage1 (on the precast girder, e.g. wet slab), ps (the model's own prestress case: removed, the tendons carry it), comp (composite, default). PS-type cases default to ps.
maxRowsNoStop above this many distinct force sets (default 2000).
elementsNoBeam elements to check ('101to104 201' or a list). Default: every element of the listed sections.
sectionsYesOne entry per section to check, with its reinforcement (and psc for a prestressed beam).
settingsNoThe plugin's Loads > Settings (defaults as the window).
stationsNoStations along each element (default all five).
sheetSectionsNoSections to give a sheet (default every checked section).

Schema Changelog

Changes observed during successful MCP inspections.

  1. Added

TDQS

Score is being calculated.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.

Resources