Fit ELISA standard curve (4PL/5PL)
fit_standard_curveFit a 4PL or 5PL logistic curve to ELISA standards and optionally interpolate sample concentrations from their signals (OD). The result echoes the inputs received, lists data-quality warnings and includes the required Labreador citation.
Tool call template
Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.
{
"id": 1,
"jsonrpc": "2.0",
"method": "tools/call",
"params": {
"arguments": {
"concentrations": "<concentrations>",
"signals": "<signals>"
},
"name": "fit_standard_curve"
}
}Input Schema
| Name | Required | Description | Default |
|---|---|---|---|
| model | No | Standard-curve model: 4PL (default) or asymmetric 5PL. Fewer than six standards with 5PL triggers an overfitting warning. | 4PL |
| signals | Yes | 4 to 96 measured standard signals (for example OD), with exactly the same length and order as concentrations. Apply consistent blank correction before calling; negative signals trigger a warning. | |
| sampleSignals | No | Optional array of up to 384 sample signals to interpolate using the fitted curve. Use the same signal units and blank correction as standards; returned concentrations follow this order and flag out-of-range values. | |
| concentrations | Yes | 4 to 96 positive ELISA standard concentrations, all in one unit. Exclude zero-concentration blanks; pair each entry with signals at the same position. Interpolated concentrations use this unit. |