FetologIA — calculadoras de medicina fetal

Anemia fetal (PVS-ACM, método de Mari) e razão cerebroplacentária

calcular_anemia_fetal
Read-onlyIdempotent

Anemia fetal (PVS-ACM, método de Mari) e razão cerebroplacentária. MoM da velocidade sistólica máxima da ACM pelo método de Mari, com limiares de anemia (1,50 MoM; 1,69 MoM pós-transfusão), e/ou razão cerebroplacentária com percentil FMF Ciobanu 2019. Faixa de validade: PVS-ACM (Mari): faixa ótima de 18 a 35 semanas; acima de 35 semanas aumentam os falso-positivos. CPR: 20 a 41 semanas. Referências: Mari G et al. N Engl J Med 2000 — diagnóstico não invasivo de anemia fetal pela PVS-ACM. SMFM Clinical Guideline #8. Am J Obstet Gynecol 2015;212:697-710 (p. 704) — limiar 1,69 MoM em fetos pós-transfusão. Ciobanu A et al. (Fetal Medicine Foundation). Ultrasound Obstet Gynecol 2019 — percentis da razão cerebroplacentária (mesma referência da calculadora de Doppler). Página para o médico conferir: https://fetologia.com/calculadoras/avancadas/anemia-fetal

Tool call template

Replace each placeholder with a value matching the input schema. Only required parameters are included; add optional parameters as needed.

{
  "id": 1,
  "jsonrpc": "2.0",
  "method": "tools/call",
  "params": {
    "arguments": {
      "modo": "<modo>",
      "ig_semanas": "<ig_semanas>"
    },
    "name": "calcular_anemia_fetal"
  }
}

Input Schema

NameRequiredDescriptionDefault
modoYesanemia_pvs_acm=cálculo de MoM pela PVS-ACM (Mari); cpr=cálculo da razão cerebroplacentária; ambos=executa os dois e retorna combinado.
ip_auNoIP da artéria umbilical. Obrigatório em modo "cpr" ou "ambos".
ip_acmNoIP da artéria cerebral média. Obrigatório em modo "cpr" ou "ambos".
ig_diasNoDias adicionais (0-6). Default 0.
ig_semanasYesSemanas de IG (componente inteiro, 11-41).
pvs_acm_cm_sNoPVS-ACM medida em cm/s. Obrigatório em modo "anemia_pvs_acm" ou "ambos".
pos_transfusaoNoSe true, aplica limiar 1.69 MoM (SMFM Clinical Guideline #8, Am J Obstet Gynecol 2015) em vez de 1.50. Default false.

Schema Changelog

Changes observed during successful MCP inspections.

  1. Changed1 schema field changed
    • changedInput schema / properties / pos_transfusao / description
      Previous value: -"Se true, aplica limiar 1.69 MoM (Mari Obstet Gynecol 2002) em vez de 1.50. Default false."New value: +"Se true, aplica limiar 1.69 MoM (SMFM Clinical Guideline #8, Am J Obstet Gynecol 2015) em vez de 1.50. Default false."
  2. First observed

TDQS

A3.7/5.0
Behavior4/5

Does the description disclose side effects, auth requirements, rate limits, or destructive behavior?

Annotations already declare readOnlyHint, idempotentHint, non-destructive, and closed-world, so the safety profile is covered. The description adds genuinely useful behavior beyond that: the 1.50 vs 1.69 MoM threshold distinction tied to pos-transfusion status, gestational-age validity windows with a stated caveat about false positives above 35 weeks, and a clinician verification URL. It does not describe the shape of the returned result, which is the main remaining gap.

Agents need to know what a tool does to the world before calling it. Descriptions should go beyond structured annotations to explain consequences.

Conciseness4/5

Is the description appropriately sized, front-loaded, and free of redundancy?

The description is front-loaded with the purpose, then labeled sections for validity range and references, which makes it scannable. The reference block (three full citations with journal, year, and page) is heavy for a tool description, though it serves verification in a clinical context. Some of that text could be trimmed without loss to an agent's decision-making.

Shorter descriptions cost fewer tokens and are easier for agents to parse. Every sentence should earn its place.

Completeness4/5

Given the tool's complexity, does the description cover enough for an agent to succeed on first attempt?

With seven parameters, an enum-driven mode, and no output schema, the description does its job of explaining what gets computed: an MoM value against defined thresholds and/or a CPR percentile against a named reference standard. What an agent still cannot tell is the concrete return structure (field names for MoM, percentile, or combined mode output), which is the one meaningful omission for a tool with no output schema.

Complex tools with many parameters or behaviors need more documentation. Simple tools need less. This dimension scales expectations accordingly.

Parameters3/5

Does the description clarify parameter syntax, constraints, interactions, or defaults beyond what the schema provides?

Schema description coverage is 100%, so every parameter (modo, ip_au, ip_acm, pvs_acm_cm_s, ig_semanas, ig_dias, pos_transfusao) is already documented in the schema, including the modo enum and the 1.69 threshold on pos_transfusao. The description reinforces the clinical meaning of the thresholds but adds no syntax or format detail the schema lacks, so the baseline of 3 applies.

Input schemas describe structure but not intent. Descriptions should explain non-obvious parameter relationships and valid value ranges.

Purpose4/5

Does the description clearly state what the tool does and how it differs from similar tools?

The description names the exact calculations performed: MoM of MCA-PSV by the Mari method with anemia thresholds, and the cerebroplacental ratio using FMF Ciobanu 2019 percentiles. The verb is implicit (it is a calculator, matching the name), but the resource and methodology are specific enough that an agent knows precisely which clinical computation this performs. It does not explicitly state how it differs from siblings such as calcular_doppler, although the note that CPR uses 'mesma referência da calculadora de Doppler' hints at the relationship.

Agents choose between tools based on descriptions. A clear purpose with a specific verb and resource helps agents select the right tool.

Usage Guidelines3/5

Does the description explain when to use this tool, when not to, or what alternatives exist?

There is no explicit 'use this tool when...' routing, nor an exclusion naming an alternative. However, the 'Faixa de validade' section gives actionable clinical constraints (PVS-ACM optimal 18-35 weeks with false-positive increase above 35 weeks; CPR 20-41 weeks), which functions as implicit guidance about when the calculation is appropriate. An agent must still infer the choice between this tool and the Doppler sibling.

Agents often have multiple tools that could apply. Explicit usage guidance like "use X instead of Y when Z" prevents misuse.

Try in Browser

Glama MCP Gateway

Add one secure layer between your agents and this server.

Resources